Search results with tag "Output"
SWAT Output Files
swat.tamu.eduthe HRU output file (output.hru), the subbasin output file (output.sub), and the main channel or reach output file (output.rch). The detail of the data printed out in each file is controlled by the print codes in the master watershed file (Chapter 3). Average daily values are always
NCP13992 - Current Mode Resonant Controller with ...
www.onsemi.comDRIVER OUTPUTS tr Output voltage rise−time @ CL = 1 nF, 10−90% of output signal 12, 14 20 45 80 ns tf Output voltage fall−time @ CL = 1 nF, 10−90% of output signal 12, 14 5 30 50 ns ROH Source resistance 12, 14 4 16 32 ROL Sink resistance 12, 14 1 5 11 IDRVSOURCE Output high short circuit pulsed current VDRV = 0 V, PW 10 s 12, 14 − 0 ...
SN74LVC1G08 Single 2-Input Positive-AND Gate datasheet ...
www.ti.comVI Input voltage range(2) –0.5 6.5 V VO Voltage range applied to any output in the high-impedance or power-off state(2) –0.5 6.5 V VO Voltage range applied to any output in the high or low state(2)(3) –0.5 VCC + 0.5 V IIK Input clamp current VI < 0 –50 mA IOK Output clamp current VO < 0 –50 mA IO Continuous output current ±50 mA
cDAQ-9189 Specifications - National Instruments
www.ni.comOutput -15 V 20 V Maximum operating conditions5 I OL output low current 8 mA maximum IOH output high current -8 mA maximum Table 2. DC Input Characteristics Voltage Minimum Maximum Positive going threshold 1.43 V 2.28 V Negative going threshold 0.86 V 1.53 V Hysteresis 0.48 V 0.87 V Table 3. DC Output Characteristics Voltage Conditions Minimum ...
A complete set of ISO 9001:2015 Quality System Procedures
c-bg.comQSP 8.7-01 Control of Nonconforming Outputs Control of Nonconforming Outputs QSP establish es a procedure for the control and disposition of nonconforming process outputs, to prevent unintentional u se or shipment. This procedure applies to all processes outputs, including nonconforming products and materials detected within Sample
CHAPTER 3: SENSORS - Analog Devices
www.analog.comOutput voltage range and gain can be easily set with external resistors. Typical gain range is usually set from 2 mV/Gauss to 6 mV/Gauss. Output voltage can be adjusted from fully bipolar (reversible) field operation to fully unipolar field sensing. The voltage output achieves near rail-to-rail dynamic range (+0.5 V to +4.5 V), capable of supplying
Chapter 5 Testing Converters F - Analog Devices
www.analog.comCHAPTER 5 TESTING DATA CONVERTERS SECTION 5.1: TESTING DACs Walt Kester, Dan Sheingold ... code to the DAC input and measuring the output. Ideally, the DAC should have an output of –FS with all "0"s at its input. The difference between the actual output and –FS is the
4.5 V to 20 V Input, 15 A, 25 A, 40 A microBuck DC/DC ...
www.vishay.comsupplying up to 40 A (SiC450) continuous output current. Its output voltage is digitally adjustable from 0.3 V to 12 V from a 4.5 V to 20 V input with switching frequencies up to 1.5 MHz. SiC45x architecture delivers ultrafast transient response with minimum output capacitance and tight regulation over a broad load range.
Typical Application - SparkFun Electronics
www.sparkfun.comOutput voltage proportional to AC or DC currents Factory-trimmed for accuracy Extremely stable output offset voltage Nearly zero magnetic hysteresis Ratiometric output from supply voltage Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor
MC7800 - Voltage Regulators – Positive
www.onsemi.cominput and the output voltages. The input voltage must remain typically 2.0 V above the output voltage even during the low point on the input ripple voltage. XX, Input MC78XX Cin* 0.33 F CO** Output These two digits of the type number indicate nominal voltage. Cin is required if regulator is located an appreciable distance from power supply filter.
The SURVEYMEANS Procedure - SAS
support.sas.comPROC SURVEYMEANS uses the Output Delivery System (ODS), a SAS subsystem that provides capabilities for displaying and controlling the output from SAS procedures. ODS enables you to convert any of the output from PROC SURVEYMEANS into a SAS data set. For more information, see the section “ODS Table Names” on page 9316.
LTM2881 - Completed Isolated RS485/RS422 µModule ...
www.analog.comn Industrial Networks n Breaking RS485 Ground Loops ... VOC Driver Common Mode Output Voltage R = 27Ω or R = 50Ω (Figure 1) l 3 V ∆ ... for Complementary Output States R = 27Ω or R = 50Ω (Figure 1) l 0.2 V IOZD Driver Three-State (High Impedance) Output Current on Y and Z DE = 0V, (Y or Z) = –7V, +12V DE = 0V, (Y or Z) = –7V, +12V, H ...
Compact 5000 Digital 16-point Sourcing Output Modules ...
literature.rockwellautomation.comYou can use time-scheduled output control on the 5069-OB16F output modules. Compact 5000™ I/O modules use the Producer/Consumer communication model. The Producer/Consumer communication model is an intelligent data exchange between module ... nel rispetto delle procedure previste.
Specified HW Configuration – SIMATIC
www.automation.siemens.com2x IO module 8x digital input DI 8x24VDC HF 2x IO module 8x digital output DQ 8x24VDC/0.5A HF 2x IO module 2x analog input AI 2xU/I 2.4-wire HS 1x IO module 2x analog output AQ 2xU/I HS 1x server module 4 Ethernet connection between the …
MAX31855 Colnction Compensate ... - Maxim Integrated
datasheets.maximintegrated.comOutput High Voltage VOH IOUT = -1.6mA VCC - 0.4 V Output Low Voltage VOL IOUT = 1.6mA 0.4 V MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter www.maximintegrated.com Maxim Integrated │2 Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board.
Using outreg2 to report regression output, descriptive ...
www.princeton.eduoutput, descriptive statistics, frequencies and basic crosstabulations (v1.6 draft) Oscar Torres-Reyna otorres@princeton.edu ... is not a Stata command, it is a user-written procedure, and you need to install it by typing (only the first time) ssc install outreg2
EEPROM Serial 2/4/8/16Kb IC - ON Semiconductor
www.onsemi.comCAT24C02, CAT24C04, CAT24C08, CAT24C16 www.onsemi.com 5 Table 7. A.C. TEST CONDITIONS Input Drive Levels 0.2 x VCC to 0.8 x VCC Input Rise and Fall Time 50 ns Input Reference Levels 0.3 x VCC, 0.7 x VCC Output Reference Level 0.5 x VCC Output Test Load Current Source IOL = 3 mA (VCC 2.5 V); IOL = 1 mA (VCC < 2.5 V); CL = 100 pF Power−On …
Dual-Channel Synchronous DC/DC Step-Down Controller with ...
www.richtek.comChannel 2. 9 BOOT2 Bootstrap Supply for Channel 2 High-Side Gate Driver. Connect to an external capacitor according to the typical application circuits. 10 UGATE2 High-Side Gate Driver Output for Channel 2. UGATE2 swings between PHASE2 and BOOT2. 11 LGATE2 Low-Side Gate Driver Output for Channel 2. LGATE2 swings between GND and LDO5.
BALUN BASICS PRIMER - Marki Microwave
www.markimicrowave.com- In time domain this means the voltage of one balanced output is the negative of the other balanced output. • The unbalanced input is matched to the input transmission line impedance (usually 50 Ω). • Unlike an isolator or circulator, a balun is …
ISO Quality Manual - LND, Inc
www.lndinc.com8.7 Control of Nonconforming Outputs SECTION 9 – PERFORMANCE EVALUATION Rev. B 9.1 Monitoring, Measurement, Analysis and Evaluation 9.1.1 General 9.1.2 Customer Satisfaction 9.1.3 Analysis and Evaluation 9.2 Internal Audit 9.3 Management Review 9.3.1 General 9.3.2 Management Review Inputs 9.3.3 Management Review Outputs
High Accuracy, Ultralow I , 1.5 A, anyCAP ... - Analog Devices
www.analog.coma load current up to 1.5 A. The ADP3339 stands out from the conventional LDOs with a novel architecture and an enhanced process that enables it to offer performance advantages and higher output current than its competition. Its patented design requires only a 1.0 μF output capacitor for stability. This device
500mA Peak Output LDO Regulator - Microchip Technology
ww1.microchip.comOct 25, 2017 · Applications • Laptop, Notebook, and Palmtop Computers • Cellular Telephones and Battery-Powered Equipment • Consumer and Personal Electronics • PC Card VCC and VPP Regulation and Switching • SMPS Post-Regulator/DC-to-DC Modules • High-Efficiency Linear Power Supplies General Description The MIC5219 is an efficient linear voltage ...
Hall Effect Measurement: Hall Bar and Van der Pauw Geometry
xiaoshanxu.unl.eduMay 20, 2016 · output to input voltage V 43, V 12 is on the order of 1/10. Van der Pauw sample geometries are thus much less efficient at using the available excitation voltage than Hall bars. Squares and circles are the most common van der Pauw geometries, but contact size and placement can significantly effect measurement accuracy. Others have shown that for
Wind Turbine Generators for Wind Power Plants
www.site.uottawa.ca• The voltage control capabilities of a WTG depend on the wind turbine type. • Type 1 and Type 2 WTGs can typically not control voltage. Instead, these WTGs typically use power factor correction capacitors (PFCCs) to maintain the power factor or reactive power output on the low-voltage terminals of the machine to a setpoint.
Air Compressors - University of Alabama
www.me.ua.eduDisturbing noise is minimized, providing a wider choice for the unit's location on the vehicle. ... • Total is 1.6% to 2% power decrease for every 2 psi drop : Lower Pressure ... output : Reduce Air Leaks • Calculations – Savings realized depend on the type of
PROCEDURE FOR CONTROL OF MEASURING AND TEST …
www.nrc.govTWS-QAS-QP-13.I, Procedure for Handling, Storage, and Shipping. TWS-QAS-QP-15.1, Procedure for Nonconformances. TWS-QAS-QP-17.1, Procedure for the LANL Group Resident File. 4.0 DEFINITIONS 4.1 Calibrate To calibrate means to check, adjust, or systematically standardize the output of a measuring or test instrument. 4.2 Calibration Certificate
030-31: The SORT Procedure: Beyond the Basics
support.sas.comThe SORT procedure is a very useful procedure with many options that often get overlooked. There are many options ... Here is how the output data set DEMO1 looks: PATIENT SEX AGE PS 1 F 45 0 2 F 39 0 3 M 57 1 3 M 57 1 SUGI 31 Coders’ Corne r. 2 4 M 63 2 4 M 63 0 5 F 72 3
PROCEDURE 1. QUALITY ASSURANCE REQUIREMENTS FOR …
www3.epa.govThis procedure specifies the minimum QA requirements necessary for the control and ... 2.5 Calibration Drift (CD). The difference in the CEMS output reading from a reference value after a period of operation during which no unscheduled maintenance, repair or adjustment took place. The reference value may be supplied by a cylinder gas, gas cell ...
Low noise JFET dual operational amplifiers
www.st.comLow noise JFET dual operational amplifiers Datasheet - production data . Features • Wide common-mode (up to V CC +) and differential voltage range • Low input bias and offset current • Low noise e. n = 15 nV/√Hz (typ) • Output short-circuit protection • …
PROGRAM, INDIKATOR KINERJA PROGRAM (OUTCOME), …
dmsppid.bantenprov.go.idrenstra yang menyelenggarakan biro organisasi program, indikator kinerja program (outcome), kegiatan dan tolok ukur (output) pada biro sekretariat daerah no indikator kinerja utama (iku) program pembangunan daerah indikator kinerja progam …
16-Bit I/O Expander with Open-Drain Outputs
ww1.microchip.comcorresponding input port register state. This is used to indicate to the system master that an input state has changed. 2. When an input state differs from a pre-configured register value (DEFVAL register). The Interrupt Capture register captures port values at the time of the interrupt, thereby saving the condition that caused the interrupt.
Backpropagation - University at Buffalo
cedar.buffalo.edu3 (1)=W 31 W 32 W 33 ... Derivative of a composite function with four inputs 8 e u v t a b d c E (a,b,c,d) = e =a.b+ c log d Derivatives by inspection: ... •The outputs of the various units depend on particular input n •We shall omit the subscript nfrom network variables •Note that E
MX-M5071 MX-M6071 ADVANCED SERIES MONOCHROME …
business.sharpusa.comOutput Size Min. 5½" x 8½", Max. 12" x 18" Copy Speed 50/60 ppm (8½" x 11") Multiple Copy Max. 9,999 copies ... XLXS, DOCX, TXT, RTF Internet Fax: TIFF-FX, TIFF-F, TIFF-S1 One-touch Up to 2,000 (combined scan destinations) Destinations Group Destinations Up to 500 Programs 48 (combined) Max. Jobs Up to 100
An Introduction to the ODS Destination for Word - SAS
www.sas.comAn Introduction to the ODS Destination for Word David W. Kelley, SAS Institute Inc. ABSTRACT The SAS® Output Delivery System (ODS) destination for Word enables customers to deliver SAS® reports as native Microsoft Word documents. The ODS WORD statement generates reports in the Office Open XML Document (.docx) format, which has been standard in
SHARC+ Dual-Core DSP with Arm Cortex-A5 - Analog Devices
www.analog.comsors (DSPs) that feature Analog Devices, Inc., Super Harvard Architecture®. These 32-bit/40-bit/64-bit floating-point proces-sors are optimized for high performance audio/floating-point applications with large, on-chip, static random-access memory (SRAM), multiple internal buses that eliminate input/output
Application on Control Technology - Siemens
cache.industry.siemens.com(a floating-point value in IEEE notation) between a specified range. ... For this example, FC41 turns on an output if the scaled value of the analog input is either above the upper range (300) or below a lower limit (100). Note Because achieving an …
JFET Input Instrumentation Amplifier with Rail-to-Rail ...
www.analog.comExcellent ac specifications and low power 1.5 MHz bandwidth (G = 1) 14 nV/√Hz input noise (1 kHz) Slew rate: 2 V/μs 750 μA quiescent supply current (maximum) Versatile MSOP package Rail-to-rail output Input voltage range to below negative supply rail 4 kV ESD protection 4.5 V to 36 V single supply ±2.25 V to ±18 V dual supply
rmarkdown : : CHEAT SHEET
raw.githubusercontent.comRENDERED OUTPUT style options 2 3 4 6 Plain text. End a line with two spaces to ... rtf_document Rich Text Format md_document Markdown github_document Markdown for Github ... Install the package to access template by going to File > New R Markdown > From Template. This is a div with some text in it..my-css-tag ...
CHAPTER 8 LABOR AND MANAGEMENT: FARM LABOR …
www.nrcs.usda.govChapter 8. Labor and Management: Farm Labor and Related Services 8-4 using input-output coefficients tied to specific tasks are most useful for projected CAR estimates where actual data on labor use are not available. A better alternative for estimating farm labor quantities is to survey farmers concerning actual use.
MCP23017/MCP23S17 Data Sheet - Microchip Technology
ww1.microchip.comInput High Voltage D040 A0, A1, A2 (TTL buffer) VIH 0.25 VDD + 0.8 — VDD V D041 CS, GPIO, SCL/SCK, SDA, RESET (Schmitt Trigger) VIH 0.8 VDD —VDD V For entire VDD range Input Leakage Current D060 I/O port pins IIL ——±1µAVSS VPIN VDD Output Leakage Current D065 I/O port pins ILO ——±1µAVSS VPIN VDD D070 GPIO weak pull-up current
Chapter 8 Frequency Modulation (FM) Contents
user.eng.umd.eduChapter 8 Frequency Modulation(FM) FM was invented and commercialized after AM. Its main advantage is that it is more ... • In quasi-static operation the filter output has the same instantaneous frequency as the input but with an envelope that varies ... The PLL input shown in the figure is the noisless
Chapter 8 – Software Testing - Pace
csis.pace.edu•Input data and output results often fall into different classes where all members of a class are related. •Each of these classes is an equivalence partition or domain where the program behaves in an equivalent way for each class member. •Test cases should be chosen from each partition. Chapter 8 Software testing 26
General purpose JFET single operational amplifiers
www.st.comJun 27, 2008 · Low input bias and offset current Output short-circuit protection High input impedance JFET input stage Internal frequency compensation Latch-up free operation High slew rate: 16 V/µs (typ) Description The TL081, TL081A and TL081B are high-speed JFET input single operational amplifiers incorporating well matched, high-voltage JFET
14-Bit, 80 MSPS/155 MSPS, 1.8 V Dual Serial Output Analog …
www.analog.comThe AD9644 is a dual, 14-bit, analog-to-digital converter (ADC) ... the industrial temperature range of −40°C to +85°C. This product is protected by a U.S. patent. ... 2 Input capacitance refers to the effective capacitance between one differential input pin and AGND.
LM324 - Single Supply Quad Operational Amplifiers
www.onsemi.comThe LM324 series are low−cost, quad operational amplifiers with ... mode input range includes the negative supply, thereby eliminating the necessity for external biasing components in many applications. The output voltage range also includes the negative power supply voltage.
LM741 Operational Amplifier - MIT
www.mit.eduOperational Amplifier General Description The LM741 series are general purpose operational amplifi- ... The amplifiers offer many features which make their applica-tion nearly foolproof: overload protection on the input and output, no latch-up when the common mode range is ex-ceeded, as well as freedom from oscillations.
Ultraprecision Operational Amplifier - Analog Devices
www.analog.com±10 V output range. CMRR of 130 dB minimum, PSRR of 120 dB minimum, and maximum supply current of 2 mA are just a few examples of the excellent performance of this operational amplifier. The combination of outstanding specifications of the OP177 ensures accurate performance in high closed-loop gain applications.
PROJECT PLANNING IN UNHCR A PRACTICAL GUIDE ON THE …
www.unhcr.org• integrate policy priorities into objectives, outputs, and indicators. For whom is this Guide 2. The guide is designed to be of use to a wide range of UNHCR and implementing partner staff working in UNHCR-funded operations. The audience for the Guide includes: • Field operations designers (e.g. Programme, Protection, Repatriation
Similar queries
SWAT Output, Output, Channel, Current, Driver, Output Voltage, Input, Voltage, Negative, Control of Nonconforming Outputs Control of Nonconforming Outputs, Control, Of nonconforming, Outputs, Nonconforming, CHAPTER 3: SENSORS, Analog Devices, CHAPTER, Output current, Application, SparkFun Electronics, SURVEYMEANS Procedure, SURVEYMEANS, Industrial, 5069, Procedure, Module, Digital, 8x24VDC, Digital output DQ 8x24VDC, Integrated, Control of Nonconforming Outputs, Peak Output LDO Regulator, Applications, Switching, Regulator, Using, Noise, Total, Calculations, Operational, Renstra, Open-Drain Outputs, Port, Inputs, Introduction to the ODS Destination, Output Delivery System, Floating, Point, Siemens, Analog, OUTPUT style, Rich Text Format, Template, CHAPTER 8 LABOR AND MANAGEMENT: FARM LABOR, Chapter 8, Labor and Management: Farm Labor and Related Services 8, MCP23017, Modulation, Chapter 8 – Software Testing, Chapter 8 Software testing, Serial Output Analog, Analog-to-digital converter ADC, Temperature, Capacitance, OP177, Guide, Objectives, outputs, and indicators