EASY RISER SWING TECHNICAL DATA CHECK VALVE …
Check Valve may replace an alarm check valve. 1-A Features 1. Ductile iron body for less weight and extra strength. 2. Rated to 300 psi (20.7 bar) water working pressure. 3. Rubber-faced clapper hinged to access cover for quick removal and easy servicing. All moving parts can be serviced without removing the valve from the installed position. 4.
Download EASY RISER SWING TECHNICAL DATA CHECK VALVE …
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
TECHNICAL DATA SPRINKLER OVERVIEW - Viking …
www.vikinggroupinc.comTECHNICAL DATA SPRINKLER OVERVIEW January 5, 2007 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Data, Technical, Overview, Sprinkler, Technical data sprinkler overview
REPLACEMENT PARTS BOOK - Viking Group Inc
www.vikinggroupinc.comVIKING REPLACEMENT PARTS BOOK The replacement parts book, offered by Viking as a convenience to its cus-WRPHUV SURYLGHV SRVLWLYH LGHQWL¿FDWLRQ IRU UHSODFHPHQW SDUWV D- QG VXE DV
Sprinkler CorroSion bulletin reSiStant FiniSheS
www.vikinggroupinc.comSprinkler CorroSion bulletin reSiStant FiniSheS July 31, 2013 the Viking Corporation, 210 n industrial park Drive, hastings Mi 49058 telephone: 269-945-9501 technical Services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
Corrosion, Finishes, Bulletin, Resistant, Sprinkler, Sprinkler corrosion bulletin resistant finishes
MICROMATIC STANDARD TECHNICAL DATA …
www.vikinggroupinc.comMICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Micromatic® Standard Response Upright Sprinklers
Standards, Data, Technical, Response, Technical data, Sprinkler, Upright, Standard response upright, Standard technical data, Standard response upright sprinkler vk200, Vk200
quick response technical data extra-large orifice …
www.vikinggroupinc.comquick response extra-large orifice upright sprinkler vk531 (storage-density/area) technical data June 28, 2013 the viking corporation, 210 …
Data, Technical, Response, Storage, Technical data, Density, Sprinkler, Upright, Response technical data, Orifice upright sprinkler vk531, Orifice, Vk531, Storage density
TECHNICAL DATA INTERMEDIATE LEVEL IN-RACK …
www.vikinggroupinc.comINTERMEDIATE LEVEL IN-RACK SPRINKLERS TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Sprinkler FM
Data, Technical, Levels, Rack, Intermediate, Sprinkler, Technical data intermediate level in rack, Intermediate level in rack sprinklers technical data
Viking Residential Sprinkler Installation Guide
www.vikinggroupinc.comViking Residential Sprinkler Installation Guide Trusted Above AllTM www.vikinggroupinc.com January 13, 2012
Guide, Installation, Viking, Residential, Sprinkler, Viking residential sprinkler installation guide
Technical Features - Viking Group Inc
www.vikinggroupinc.comWorldwide Fire Protection CPVC Pipe & Fittings wwwvikinggroupinccom BlazeMaster® CPVC Pipe BlazeMaster® CPVC Pipe Product Specifications
Installation and Maintenance Guide for NIBCO …
www.vikinggroupinc.comInstallation and Maintenance Guide for NIBCO Butterfly Valves with Rubber ... Procedure Section of this instruction booklet on page 5 if stop alignment adjustment is ...
Guide, Installation, Section, Maintenance, Valves, Butterfly, Butterfly valves, Installation and maintenance guide for
concealed sprinkler tecHnical data cover plate …
www.vikinggroupinc.comconcealed sprinkler cover plate assemblies tecHnical data May 21, 2013 the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
Data, Plate, Technical, Concealed, Cover, Sprinkler, Concealed sprinkler technical data cover plate
Related documents
Backflow Prevention - Watts
media.wattswater.comMain valve body: Ductile iron Grade 65-45-12, Fusion Epoxy coated, Internal and External, AWWA C550-90 Trim: Bronze Elastomers: Nitrile Spring: Stainless Steel Bypass: Copper alloy tube and fittings Bypass meter: Totalizing type GPM/CFM Size: 5⁄8" x 3⁄4" Approvals 4", 6", 8" and 10" Series 800 Detector Check for Automatic Fire Sprinkler Systems
Prevention, Iron, Valves, Ductile, Backflow, Ductile iron, Backflow prevention
V. DESIGN OF WATER MAINS - Charlotte, North Carolina
charlottenc.govMain line valves shall be located at all pipeline intersections and at changes in pipe diameter. Maximum valve spacing shall be 1500 feet in the distribution system and 3000 feet for transmission mains 16-inches in diameter and larger. Two valves shall be provided at tees and three valves at crosses, with valves located
XIV. STANDARD WATER SPECIFICATIONS AND DETAILS …
charlottenc.gov1. Ductile Iron Pipe: Ductile iron pipe shall conform to the requirements of AWWA Standard C-151 and shall have a cement-mortar lining of standard thickness in accordance with AWWA C-104. Unless otherwise shown on the construction plans, all ductile iron pipe shall be furnished with push on joints in accordance with AWWA C-111.
DeZURIK PEF 100% PORT ECCENTRIC PLUG VALVES …
www.dezurik.comECCENTRIC PLUG VALVES TECHNICAL SPECIFICATIONS JUNE 2021 12.60-1B www.dezurik.com. 2 www.dezurik.com ... AWWA C517-16 Resilient-Seated Cast-Iron Eccentric Plug Valve. ASME flange drilling conforms to ASME B16.1 Class 125, ASME B16.5 Class 150, and ASME B16.42 Class 150. ... Ductile Iron, ASTM A536 A2 Body Bearing 316L Stainless …
Specification, Technical, Iron, Valves, Ductile, Plugs, Eccentric, Ductile iron, Eccentric plug valves, Eccentric plug valves technical specifications
Fisher Sliding Stem Valve Selection Guide - Emerson
www.emerson.comFisher Three-Way Valves, Cryogenic, and Lined Valve Figure 4. Three-Way, Cryogenic, and Lined Valves YD and YS W0665-3 ... specifications) Ratings CL125, 150, 250, 300, 600 PN 10, 16, 25, 40 ... stainless steel Stainless steel Ductile iron with PFA liner Valve Plug and Seat Ring (Trim) Materials Stainless steel
Guide, Specification, Selection, Iron, Valves, Ductile, Sliding, Fisher, Stem, Ductile iron, Fisher sliding stem valve selection guide