INSULATED ROOFING,
For Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Download INSULATED ROOFING,
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
INSULATED ROOFING, - stratco.com.au
www.stratco.com.auCOOLDEK® ROOFING INSULATED PATIO ROOFING TABLE 3.0 - SINGLE SPAN WIND CAPACITIES (kPa) SPAN (mm) P r o fi l ePanel Thickness Limit State 1800 …
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
OVERFLOW SOLUTIONS - Stratco
www.stratco.com.ausystem (who may be the architect, builder, hydraulic engineer, home owner, roofing or guttering contractor) to design a ... The following overflow solutions provide a measure for continuous overflow for the full length in which the solution is applied.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
SUPERDEK - Stratco
www.stratco.com.auRoofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing spans for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance. All pressures have been determined assuming wind
Related documents
Pella Architectural Design Manual
media.pella.comand Patio Doors Pella ® Reserve ™ ... • Roomside wood grilles are securely attached to the interior, but can be removed for glass cleaning • Typical grilles are 3/4" wide, other standard and custom widths and profiles are available 3/4" 3/4", 1-1/4", and 2" widths Grilles-Between-the-Glass 1
Frame Assembly and Installation Guide
www.andersenwindows.comPatio Door) Side Jamb Side Installation Flange ... · Fasteners must be attached to a structural framing member. Failure to do so will reduce the structural performance to less than published values and could affect product performance, and could result in product or property damage.
Limited Lifetime Warranty - Andersen Windows
www.andersenwindows.comPatio Doors with Shades/Blinds in Insulated Glass Subject to the terms and conditions stated herein, the shades/blinds in insulated glass (including insulated glass, shade/blind insulated glass seal and external control mechanisms attached to the glass) in Silver Line® patio doors
9100 POWER PATIO AWNING INSTALLATION INSTRUCTIONS
www.dometic.comchannel, awning fabric is attached to awning rail, and arm assembly is mounted to RV. Arm assemblies are under tension from gas strut. Removing these ties could allow arms to extend quickly and unexpectedly. Failure to obey this warning could result in death or serious injury. Insert each top casting into corresponding front channel. See (FIG.
Power, Patio, 9100, Awning, Attached, 9100 power patio awning
patio cover rafter & beam spans-2020 - Fort Collins, Colorado
www.fcgov.comDec 18, 2020 · 1.Patio cover supported by or attached directly to the top of a deck. 2.Ledger attached to a cantilever/ overhang on the house. 3.Ledger attached to rafter tails/ fascia board of existing house roof. 4.Metal or Plastic patio structures 22sf …
STRUCTURAL MEMBER ALLOWABLE DEFLECTION
www.iccsafe.orgadditions or patio covers, the total load deflection shall not exceed L/120. d. Deflection for exterior walls with interior gypsum board finish shall be limited to allowable deflection of H/180. e. d. Refer to Section R703.7.2 Reason: This is intended to be an editorial clean-up and not change any current requirements for deflection criteria.
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.