INTERIOR SHEAR WALLS - awc.org
interior shear walls to be designed to resist wind loads. WFCM Section 2.4.4.2 states: “Walls parallel to the applicable wind load or seismic motion shall provide the required shear resistance at each level. The sum of the individual shearwall segment shear
Download INTERIOR SHEAR WALLS - awc.org
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
2012 ASD/LRFD Manual for Engineered Wood Construction
www.awc.orgASD/LRFD MANUAL FOR ENGINEERED WOOD CONSTRUCTION iii AMERICAN WOOD COUNCIL FOREWORD This Allowable Stress Design/Load and Resistance Factor Design Manual for Engineered Wood Construction (ASD/LRFD Manual) provides guidance for design of most wood-based structural products used in the construction
Construction, Woods, Engineered, Engineered wood construction
Prescriptive Residential Wood Deck Construction Guide
www.awc.org4 PRESCRIPTIVE RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE American Wood Council Table 2. Maximum Joist Spans and Overhangs.1 Species Size Joist Spacing (o.c.)
2015 National Design Specification Supplement - awc.org
www.awc.orgAMERICAN WD CUNCIL. DESIGN VALUES FOR WOOD CONSTRUCTION – NDS SUPPLEMENT iii. Introduction. This Supplement is a compendium of reference de …
2005 Span Tables For Joists And Rafters - awc.org
www.awc.org2 EXPLANATION OF TABLES AMERICAN WOOD COUNCIL 7. LUMBER IDENTIFICATION The tabulated spans in these tables apply to lum-ber identified by the grade stamp of, or certificate of
Design Aid 6 Beam Design Formulas with Shear and Moment ...
www.awc.orgAMERICAN WOOD COUNCIL w R V V 2 2 Shear M max Moment x 7-36 A ab c x R 1 R 2 V 1 V 2 Shear a + — R 1 w M max Moment wb 7-36 B Figure 1 Simple Beam–Uniformly Distributed Load
WIND & SEISMIC - AWC
www.awc.org2.1.2.1 Allowable Stress Design: Allowable stress design (ASD) shall be in accordance with the Na-tional Design Specification ® (NDS ®) for Wood Con-struction (ANSI/AF&PA NDS-05) and provisions of this document. 2.1.2.2 Strength Design: Load and resistance factor design (LRFD) of wood structures shall be in accor-
WCD1 - Details for Conventional Wood Frame Construction
www.awc.orgmay provide equal, or possibly, improved performance. These, however, must provide performance assurance ac-ceptable to the owner and the building inspector. Dimensioning. In general, dimensions for framing lumber, wood sid-ing and trim referenced in this document are nominal dimensions; i.e., 2x4, 2x6, etc., for simplicity. Actual sur-
Prescriptive Residential Wood Deck Construction Guide
www.awc.org3. Maximum allowable overhang cannot exceed L/4 or ¼ of actual main span. Assumes cantilever length/180 deflection with 220 lb point load (See Figure 1A and Figure 2). 4. Incising assumed for Douglas Fir-Larch, Hem-Fir, and Spruce-Pine-Fir. 5. Design values based on northern species with no incising assumed. 6. Ledger shall be a minimum of 2x8 ...
Guide, Construction, Deck, Maximum, Minimum, Deck construction guide
2015 National Design Specification - AWC
www.awc.orgNDS-1991 with an approval date of October 16, 1992. In 2010, AWC was separately incorporated, re-chartered, and accredited by ANSI as a standards developing organization. The current edition of the Standard is designated ANSI/AWC NDS-2015 with an approval date of September 30, 2014. In developing the provisions of this Specification,
Design, Specification, 2015, National, October, 2015 national design specification
MAT100: The Basics of Wood Frame Construction
www.awc.orgone comprehensive program for building officials on wood frame construction basics. In each module, learning outcomes will be further refined respectively. MAT 100 learning outcomes (see slide). 5 MAT100: Learning Outcomes 3. Floor, roof/ceiling, wall framing 4. Wall bracing, introduction to Wood Frame Construction Manual 5. Fireblocking ...
Related documents
INTERIOR LATEX PAINT FOR WALLS AND CEILINGS - PPG
buyat.ppg.comTECHNICAL DATA SHEET SICO EXPERT 871-6XX INTERIOR LATEX PAINT FOR WALLS AND CEILINGS Water-based product, flat finish Before use, be sure to read and follow the instructions and warnings on the label and Safety Data Sheet.
Walls, Interior, Paint, Latex, Interior latex paint for walls
CHAPTER 6 WALL CONSTRUCTION - eCodes
ecodes.bizCHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL R601.1 Application. The provisions of this chapter shall con- ... R602.4 Interior load-bearing walls. Interior load-bearing walls shall be constructed, framed and fireblocked as specified for exterior walls. R602.5 Interior nonbearing walls.
Chapter, Construction, Walls, Interior, Chapter 6 wall construction
CONTROL JOINTS FOR CONCRETE MASONRY WALLS— TEK …
masonpro.comCONTROL JOINTS FOR CONCRETE MASONRY WALLS— ... both exterior and interior walls. While these attributes are the primary basis for concrete masonry’s popularity, performance should not be taken for granted. Like all con-struction systems, design decisions significantly influence
Control, Walls, Joint, Concrete, Masonry, Interior, Control joints for concrete masonry walls, Interior walls
INTERIOR METAL STUD FRAMING 1.1 SECTION INCLUDES
sliptrack.comA. Interior Walls: Metal stud framing system with [batt] [_____] type acoustic insulation specified in Section [________], interior gypsum board specified in Section The deflection limits in the following paragraph relate directly to the nature, type, and
Walls, Metal, Farming, Interior, Dust, Interior metal stud framing, Interior walls
THE CONSTRUCTION OF TILT-UP
tilt-up.org4 The CONSTrUCTION OF TIlT-UP Interior Fooding Pads Foundations Supporting Wall Panels Specifying Concrete For Foundations ... What began more than 65 years ago as a novel way to build concrete walls for warehouses and manufacturing plants grew to a multi-billion dollar market, with an estimated 15% of all ...
Construction, Walls, Interior, Tilt, The construction of tilt up, The construction of tilt up interior
Light Gauge Metal Roof and Wall Panels
www.ascbp.comLight Gauge Metal Roof and Wall Panels Installation Guide for Delta Rib ™, Delta Rib III, Nor-Clad®, Strata Rib® & 2½ Corrugated 2 August 2018 • ASC Building Products www.ascbp.com In addition to weather tightness, long life, good looks and economy, ASC Building Product’s Light Gauge Roof
Walls, Metal, Roof, Light, Panels, Gauge, Light gauge metal roof and wall panels
The heart walls and coronary circulation - Wiley-Blackwell
www.blackwellpublishing.comThe heart walls and coronary circulation The heart is located in the central-left part of the thorax (lying on the di-aphragm) and is oriented anteriorly, with the apex directed forward, down-ward, and leftward. The myocardium and specific conduction system are per-
Earth, Walls, Circulation, Coronary, Heart walls and coronary circulation
Interior Finishes - CRA | California Redwood Association
www.calredwood.orgInterior Finishing Rules The following rules will facilitate ... Interior Finishes Description Uses Effect Application Maintenance Light traffic areas, ceilings, walls, panels and trim not cleaned often. Do not use in kitchens, bathrooms or other areas exposed to moisture and grease.
Exterior and Interior WALL MANUAL - Cedar Shake and ...
www.cedarbureau.orgExterior and Interior WALL MANUAL R. Credits, front cover: Left column 1. Architect: Shope Reno Wharton, Photo: Robert Benson ... shakes are applied on walls in a different manner than on roofs. The major point of ... for Exterior and Interior Walls” This manual is intended for use with Western
Manual, Walls, Exterior, Interior, Exterior and interior wall manual, Interior walls
INTERIOR FINISH OF WALLS AND CEILINGS
www.constructionknowledge.netINTERIOR FINISH OF WALLS AND CEILINGS Builders are responsible for finishing the interior of the buildings of a construction project. Interior finish consists mainly of the coverings of the rough walls, ceilings, and floors, and installing doors and windows with …
Walls, Finish, Ceiling, Interior, Interior finish of walls and ceilings
Related search queries
INTERIOR LATEX PAINT FOR WALLS, CHAPTER 6 WALL CONSTRUCTION, Interior, Walls, CONTROL JOINTS FOR CONCRETE MASONRY WALLS, Interior Walls, INTERIOR METAL STUD FRAMING, THE CONSTRUCTION OF TILT-UP, The CONSTrUCTION OF TIlT-UP Interior, Light Gauge Metal Roof and Wall Panels, Heart walls and coronary circulation, Interior Finishes, Exterior and Interior WALL MANUAL, INTERIOR FINISH OF WALLS AND CEILINGS