Modular Make-Up Air Unit
• Distribution terminal strip • UL Listed, Recognized, or Classified electrical components • Factory prewired for single-point power connection 7 9 7 8 Optional Electrical Accessories Auxiliary Contacts – Normally open and normally closed contacts are available for supply fan status and supply fan interlocks.
Make, Unit, Modular, Accessories, Terminal, Modular make up air unit
Download Modular Make-Up Air Unit
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Minimum 180 in-lb Torque Applications
content.greenheck.comFor damper areas up to 45 sq-ft*(For lower torque, see AF, NFB, LF, ... Time to fit your Specific Application with Belimo’s Flexible Line of ... done in accordance with the damper manufacturer’s specifications. Control is On/Off from an auxiliary contact, or a manual switch. ...
Heating and Ventilating Units - content.greenheck.com
content.greenheck.com2 Heating Options Hot water, steam and electric heat options are available. The heating section consists of a factory-installed heating coil in a pre-engineered housing.
Energy Recovery and Make-Up Air Start-Up Report
content.greenheck.com5 Condenser Airflow S 6 6 4 8 5 3 4 12 4 1 2 14 13 11 10 9 Supply Airflow P1 P2 T1 T2 Packaged DX Cooling with Digital Scroll Compressor Water-Source Heat Pump with Standard Scroll Compressor
Indirect Gas-Fired Make-Up Air - content.greenheck.com
content.greenheck.com5 Controls Discharge Temperature Control In make-up air units, the unit-controlled heat output is based on discharge temperature. A factory-mounted
High Performance Vane Axial Fans - content.greenheck.com
content.greenheck.comfi 2 Model RA High Performance Vane Axial Fans RA high performance, direct-driven vane axial fans are ideal for inline air ventilation in commercial, institutional or industrial buildings.
Centrifugal Ceiling Exhaust and Inline Cabinet Fans
content.greenheck.com3 Model Comparison Model Location Mounting Airflow Application Drive Type Impeller Type Performance Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted Exhaust Supply Reversible Recirculate General/Clean Air Contaminated Air Spark Resistant Grease (UL 762) Smoke Control (UL) High Wind (150 mph) High Temp (above 200°F ) Belt Direct Centrifugal Propeller/Axial …
Installation, Operation and Maintenance Manual
content.greenheck.com2 Ceiling Exhaust and Inline Fans ® Typical Installation The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of
FumeJet Exhaust Systems - content.greenheck.com
content.greenheck.com2 Greenheck’s FumeJet® line of exhaust fans with integral stacks are designed to safely remove and disperse fumes and odors. FumeJet systems replace utility set fans with field supplied intake
Installation, Operation and Maintenance Manual
content.greenheck.comUpblast Centrifugal Roof Exhaust 3 ® When lifting a Belt Drive unit onto the roof, use either the four lifting points on the drive frame or the two lifting
BSQ Centrifugal Inline Fan - content.greenheck.com
content.greenheck.comBSQ Centrifugal Inline Fan New Dimensions Supplement Belt Drive July 2015 BSQ Redesign In early 2015, the BSQ was redesigned. The redesign changes some mounting dimensions
Related documents
FXZQ-M 4-Way Ceiling Mounted Cassette Unit (2' × 2')
www.daikinac.coma4p x1a receiver/display unit h2p x2a a1p x1a x23a note) 3 t1r power supply 208-230v ~ 60hz notes) 1. : terminal , : connector : field wiring 2. in case using central remote controller, connect it to the unit in accordance with the attached installation manual. 3.
Unit, Mounted, Ceiling, Terminal, Cassette, 4 way ceiling mounted cassette unit
PTAC Packaged Terminal Air Conditioners & Heat Pumps ...
friedrich.com2. Make sure the unit is the right capacity for the area being cooled. An undersized unit makes the unit work too hard, using more electricity than needed and increases wear. An oversized unit will cycle on and off too rapidly, and therefore cannot control humidity as well. 3. Clean the filter frequently (See Routine Maintenance, Page 27). 4.
Product Selector - 1SXP210003C0201 ABB Molded Case …
library.e.abb.comXT4 Accessories 3/52 Tmax T ranges 4/1 General Information Introduction 4/2 Circuit breakers for power distribution 4/4 Catalog number explanation 4/6 Ordering details T5, 300/400/600A, 600VAC 4/13 T6, 600/800A, 600VAC 4/15 Accessories 4/17 T7, 1000/1200A, 600VAC 4/24 T7M, 1000/1200A, 600VAC 4/27 Accessories 4/30
PanelView Plus Terminals User Manual - Rockwell …
literature.rockwellautomation.comThe base-configured unit of the 400 and 600 terminals is available in two versions. Base unit with RS-232 port and one USB port Base unit with RS-232 port, 10/100BaseT Ethernet port, one USB port, and a network interface for a communication module Base Unit with RS-232 Only
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT
www.hitachi.com.auEarth terminal (Lower section of the side) About the outdoor unit: • When “Stop” is selected during operation of the . indoor unit, the fan of the outdoor unit continues turning for 10 to 60 seconds to cool the electric parts down. • In heating operation, condensate or water due to . defrosting will flow. Do not cover the drain port of the
Terminal Units Engineering Guide - Price Industries
www.priceindustries.comThe basic single duct terminal unit with reheat is similar to the single duct, but has a reheat option built into the unit. The reheat option is either a water coil, or an electric heater. Accessories for the single duct with a water coil include access doors in the coil section upstream and downstream of the water coil.
D4120 Duct Smoke Detector - System Sensor
www.systemsensor.comremote accessories The InnovairFlex D4120 4-wire photoelectric duct smoke ... Similarly, connect the INT/AUX– terminal on unit 1 to the INT/AUX- terminal on unit 2 and so on. • Up to 50 D4120 units, 50 D4P120 units, or 50 units of combination may be interconnected.
Unit, Accessories, Smoke, Terminal, Detectors, Duct, D4120, D4120 duct smoke detector