System Level ESD Expanded - JEDEC
Model IEC system level ESD Human Body Model (HBM) Environment End customer’s normal operation Factory assembly Standard example Test IEC 61000-4-2 (Powered) ISO 10605 (Unpowered / Powered) JS-001-2013 (Unpowered only) R-C network Peak current 3.75 A / kV 0.7 A / kV Typical requirement 8 KV 1 KV (Formerly 2kV)
Download System Level ESD Expanded - JEDEC
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
ESD Control – Revised Document May 2013 - …
www.jedec.orgBasic ESD Control Program •If the precautions described in the bullets below are followed, the charge on personnel and work surfaces will be less than 100V.
Programs, Document, Control, Dse control, Esd control program
System Level ESD - jedec.org
www.jedec.orgSystem Level ESD • What is an ESD Event? - Object becomes charged -> discharges to another - Charging levels range from 1 V to 35,000 V Discharge currents range from 1 A to 60 A or more • What is a System Level ESD Event? - An electrical system experiences an ESD Event
JEDEC SSD Specifications Explained
www.jedec.orgUBER equality question Example: 70GB, TBW rating = 70TB 0 0.01 0.02 0.03 0.04 0.05 0.06 0 200 400 600 800 1000 Drive Rewrites SSDHDD Instantaneous UBER for the spec ...
Charged Device Model (CDM) Qualification Issues
www.jedec.org• CDM is a unique and important test method for IC ... •1681-LGA Product has 320 High Speed pins ... necessary for specific handling processes in the EPA •Additional measures for CDM should include a process specific assessment to control charging of insulators in the
JEDEC SSD Specifications Explained
www.jedec.orgdetermine the relationship between host writes and NAND cycles, the latter being the number of p/e cycles applied to any NAND block, and use this relationship to estimate the SSD endurance rating. If the SSD employs more than one type of NAND component with different cycling capabilities, then a separate relationship should be obtained for each
User Guide of ANSI/ESDA/JEDEC JS-001 Human Body Model ...
www.jedec.orgThe joint ESDA/JEDEC HBM Standard JS-001-2010 merged the JEDEC HBM Standard, JESD22-A114F, and the ESDA HBM Standard, ANSI/ESD STM5.1-2007, into a single document. This accomplishment was a significant advance for the industry, since it reduced the confusion
LPDDR3 and LPDDR4 - JEDEC
www.jedec.orgChannel 0 Rank 0 Modem, OS Kernel, Running apps Basic “keep alive” AOAC Low frequency Ch0 R1 active Channel 1 Rank 0 High Resolution Video Processing, Image Processing, etc Channel 0 Rank 1 Stalled/Sleeping Apps Channel 0 Channel 1 Application Processor Channel 1 Rank 1 High Resolution Video Processing, Image Processing, etc
Flash Technology - JEDEC
www.jedec.org3. PKG Cap: 2.03pF. 4. VccQ: 1.8V . 5. Transmission Line : 50ohm (X-talk included) 6. Termination : 100 Ω. 7. Freq: 400Mbps(200MHz) Driver/Receiver\爀刀漀渀 㨀 㠀⼀㈀㔀⼀㌀㔀⼀㔀〃꤀ 屲NAND Cin : 3.5 pF/Chip\爀䠀漀猀琀 䌀椀渀 㨀 㠀瀀䘀 尨including Host PKG\⤀屲PKG Model\爀䰀甀洀瀀攀搀 刀䰀䌀屲 \⠀刀 ⸀㑜ഀ㠀㔃꤀ Ⰰ 䰀㴀㜀 ...
Related documents
3.3 V powered, 15 kV ESD protected, up to 20 Mbps RS-485 ...
www.farnell.com3.3 V powered, 15 kV ESD protected, up to 20 Mbps RS-485/ RS-422 transceiver Datasheet -production data Features ESD protection – ± 15 kV human body model – ± 8 kV IEC 1000-4-2 contact discharge Operate from a single 3.3 V supply - no charge pump required Interoperable with 5 V logic 1 µA low current shutdown mode max.
AN048 The Basic Principles of Electrical Overstress (EOS)
dammedia.osram.infoMany OSRAM Opto Semicond uctors LEDs have ESD pr otection devices that are meant to protect the LED from ESD even ts. OSRAM Opto Semiconductors latest products are protected up to 8 kV HBM (human body mode l) or up to 15 kV acc. to IEC 61000-4-2 (air discharge). Features SYNIOS® P 2720: • Package: SMD epoxy package • Technology: UX:3
MAX3222E/MAX3232E/MAX3237E/MAX3241E/MAX3246E …
datasheets.maximintegrated.comHuman Body Model ±15 IEC 1000-4-2 Air-Gap Discharge ±15 kV IEC 1000-4-2 Contact Discharge ±8 www.maximintegrated.com Maxim Integrated │ 3 MAX3222E/MAX3232E/ MAX3237E/MAX3241E/ MAX3246E ±15kV ESD-Protected, Down to 10nA, 3.0V to 5.5V, Up to 1Mbps, True RS-232 Transceivers Electrical Characteristics (continued)
MAX3483E/MAX3485E/MAX3486E/MAX3488E/MAX3490E/MAX3491E …
datasheets.maximintegrated.com3.3V-Powered, ±15kV ESD-Protected, 12Mbps and Slew-Rate-Limited True RS-485/RS-422 Transceivers Absolute Maximum Ratings Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
1794-TD014A-EN-P 1794 FLEX I/O Communication Adapters ...
literature.rockwellautomation.comESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80… 2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity IEC 61000-4-4:
SurfLink Remote Control Operations Manual
starkeypro.com• Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air discharge. Hereby, Starkey Hearing Technologies declares that the products listed above are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the Declaration of Conformity
TJA1040 High speed CAN transceiver
www.nxp.compowered networks. QUICK REFERENCE DATA ORDERING INFORMATION SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT VCC supply voltage operating range 4.75 5.25 V ICC supply current standby mode 5 15 µA VCANH DC voltage on pin CANH 0 < VCC < 5.25 V; no time limit −27 +40 V VCANL DC voltage on pin CANL 0 < VCC < 5.25 V; no time limit −27 …
1. General description - NXP
www.nxp.comTransceiver disengages from the bus when not powered up (zero load) 2.3 Protection High ESD handling capability on the bus pins Bus pins protected against transients in automotive environments Transmit Data (TXD) dominant time-out function Bus-dominant time-out function in Standby mode Undervoltage detection on pins VCC and VIO
General, Descriptions, Powered, Protected, General description
Remote Operations Manual - Starkey
www.starkey.com• Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air discharge. The Remote has a rating of IP 5X per IEC 60529. This means that the Remote is protected from dust. The Remote does not contain any user-serviceable parts. Do not open or modify this device. Do not connect the Remote to any external device.