TECHNICAL DATA SHEET - Insulation Systems, Commercial ...
for mechanical insulation systems including pipe, vessels, and equipment. It protects the insulation and underlying pipe/vessel from physical damage, UV exposure, corrosive atmospheres, and water. JM Aluminum jacketing (also called cladding) is available in smooth, stucco embossed, and 3/16 corrugated (cross-crimped) finishes.
Download TECHNICAL DATA SHEET - Insulation Systems, Commercial ...
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Mineral Wool Insulation - Johns Manville
www.jm.comSAFETY DATA SHEET 200000002057 Mineral Wool Insulation Version 2.1 Revision Date 02/26/2018 Print Date 02/26/2018 3 / 6 US/EN Materials to avoid
EXPAND-O-FLASHEXPANSION JOINT COVER
www.jm.comEXPAND-O-FLASH ® EXPANSION JOINT COVER Flexible, Weatherproof Joint Opening Covers. RS-6016 2-17 (Replaces 10-14) Features and Components Expand-O-Flash expansion joint covers are flexible, weather-proof
Cover, Joint, Expansion, Expand, Expand o flashexpansion joint cover, Flashexpansion
SBS Modified Bitumen Specifications - Johns Manville
www.jm.com3-79 SBS Modified Bitumen Specifications 7.0 Roofing Bitumens 7.1 JM modified bitumen products are designed to be installed with hot asphalt or special cold …
Specification, Modified, Cold, Bitumen, Sbs modified bitumen specifications
IIG Product Selector Guide - jm.com
www.jm.comMinWool-1200® Field-Formed Pipe Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness Single Layer: 1½-4” thick Double Layer: Over 4” …
Asphalt-Applied and Cold Application Built-Up Roofing ...
www.jm.comAsphalt-Applied and Cold Application Built-Up Roofing Application Guide. Built-Up Roofing Application Guide TWO SECTION 2-2 RS-4927 2-14 (Replaces 11-13) Asphalt-Applied and Cold Application Built-Up Roofing Application Guide 3.2 These specifications are also for use over JM roof ... Do not mix different grades of asphalt or dilute asphalt with ...
Guide, Applications, Applied, Cold, Asphalt, Built, Asphalt applied and cold application built
SBS Modified Bitumen Specifications
www.jm.com3-77 SBS Modified Bitumen Specifications 1.0 General Information 1.1 This section provides application information, and outlines specifications currently available from JM Roofing Systems for SBS (Styrene-Butadiene-Styrene) Modified Bitumen Roofing Membranes.
Specification, Modified, Bitumen, Sbs modified bitumen specifications
Formaldehyde-free™ Fiberglass Insulation
www.jm.comSAFETY DATA SHEET 200000002059 Formaldehyde-free™ Fiberglass Insulation Version 1.6 Revision Date 09/25/2018 Print Date 10/03/2018 1 / 6 US/EN SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Trade name : Basement Wall Insulation® - Unfaced, Steel Frame Thermal and Acoustical Fiberglass Insulation, Spin-Glas® TC EQ, ...
AP Foil-Faced - jm.com
www.jm.comDESCRIPTION Johns Manville AP™ Foil-Faced Polyiso Continuous Insulation board consists of a uniform closed-cell polyisocyanurate foam core bonded on each side to a foil facer. One side has a reflective foil facer and the other side has a white non-reflective foil facer to suit your building needs.
EXPAND-O-FLASHEXPANSION JOINT COVER
www.jm.comEXPAND-O-FLASH ® EXPANSION JOINT COVER Flexible, Weatherproof Joint Opening Covers. RS-6016 8-18 (Replaces 2-17) Features and Components Expand-O-Flash expansion joint covers are flexible, weather-proof
FESCANT PLUS CANT STRIP TAPERED FESCOEDGE STRIP
www.jm.comFESCANT PLUS CANT STRIP TAPERED FESCO ® EDGE STRIP Perlite-Based Specialty Accessory Product Typical Physical Properties* Test ASTM FesCant Plus Cant Strip* Tapered FESCO Edge Strip*
Plus, Strips, Tapered, Reptiles, Ncat, Fescant plus cant strip tapered, Fescant
Related documents
INSULATION OF PIPING & EQUIPMENT (PROJECT …
www.klmtechgroup.comInsulation materials shall have the following properties: - Completely free from all forms of asbestos. - Water-soluble chloride and fluoride ion concentrations as low as possible, 20ppm by mass maximum. - Chemically neutral, with pH preferably between 7 and 8 in the wet condition.
How to Properly Insulate a Slab
www.phrc.psu.eduperimeter slab insulation Heat Loss through an Insulated Slab Windows 33% Roof/Ceiling 8% Slab 15% 6 Doors 5% Walls 39% Insulation and Fenestration Criteria Table 402.1.1 Insulation and Fenestration Requirements by Componenta CLIMATE ZONE FENESTRATION U-FACTORb SKYLIGHTb U-FACTOR GLAZED FENESTRATIONb,e SHGC CEILING R-VALUE WOOD …
THE THICKNESS OF ROCKWOOL INSULATION
www.rockwool.comMinimum insulation thickness for condensation control on ductwork carrying chilled air in ambient conditions: indoor still air temperature 15 13 +25°C, relative humidity 80%, dewpoint temperature 21.3°C 16 14 Indicative thickness of insulation for ductwork carrying warm …
Expanded Polystyrene (EPS) Insulation Board
www.stocorp.com4. Projections – Insulation board shall be free of surface projections or wire marks in excess of 1/16 inches (1.6 mm). Packaging All insulation board shall be packaged in polyethylene bags as required by the EIFS manufacturer. Alternative methods of packaging shall be submitted to the EIFS manufacturer and approved in writing prior to use.