TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND …
given in Technical Data Sheet 16, Species Properties and Uses. Allowance should therefore be made for shrinkage in unseasoned bearers, joists and decking, and for the gaps that will develop between the decking boards. A minimum gap of 6 mm is recommended between decking boards to allow for good drainage and ventilation around boards.
Download TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND …
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 19 PERGOLAS AND CARPORTS Revised March 2014 Page 3 PERGOLA OR CARPORT BEAMS Tables 2L and 2H list the sizes and spans for pergola or carport beams in low wind speed and higher wind speed areas.
Issued, Timber, Issued by timber, Pergolas and carports, Pergolas, Carports
06 - Treated and Engineered Timber Products | …
www.hyne.com.au06 Technical Design Guide issued by Forest and Wood Products Australia Timber-framed Construction Sacrificial Timber Construction Joint
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 15 SPECIFYING TIMBER Revised March 2014 Page 2 TERMITES Termite management of all building shall be in accordance with the
The characteristic properties of our glue …
www.hyne.com.aucharacteristic design properties suitable for limit state design in accordance with as1720.1 date of issue: july 2017 this document supersedes all previous versions
Design, Properties, Characteristics, Glue, The characteristic properties of our glue
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 23 TIMBER HANDRAILS & BALUSTRADES Revised March 2014 Page 2 MATERIALS (Timber - general) Durability In weather exposed above ground applications or, where subjected to other sources of moisture, handrails, posts, newels, balusters, and
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 28 MOISTURE IN TIMBER Revised March 2014 Page 1 An understanding of the way in which moisture in timber affects in-service performance is important as it
The requirements for handling and storing Glulam …
www.hyne.com.auTECHNICAL DATA SHEET #5 DATE OF ISSUE: JULY 2016 THIS DOCUMENT SUPERSEDES ALL PREVIOUS VERSIONS The requirements for handling and storing Glulam products.
Product, Requirements, Handling, Storing, Glulam, Requirements for handling and storing glulam, Requirements for handling and storing glulam products
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 9 TIMBER RETAINING WALLS Revised March 2014 Page 3 BATTER Gravitational forces cause the backfill to slide towards the wall.
TECHNICAL DATA SHEET ISSUED BY TIMBER …
www.hyne.com.au©TIMBER QUEENSLAND LIMITED TECHNICAL DATA SHEET 20 RESIDENTIAL TIMBER FENCES Revised March 2014 Page 3 PLINTH Where a plinth is provided at the base of sound fences, (to enclose
Sheet, Data, Residential, Data sheet, Timber, Fence, Residential timber fences
41 - hyne.com.au
www.hyne.com.auWoodSolutions is an industry initiative designed to provide independent, non-proprietary information about timber and wood products to professionals and companies involved in …
Related documents
Bridge Design Guide - Field Office Technical Guide
efotg.sc.egov.usda.govThis design guide is a technical resource prepared by the MarylandNRCS Engineering staff, adopted for use in Alabama, and is intended for use by the NRCS in Alabama and its partners. The bridge designs contained in this design guide are offered as an alternative to other types of stream crossing such as fords and culverts.
Technical document
cdn.pefc.orgTechnical document 15.10.2021 PEFC Product Categories Context ... 080103 Decking and garden sleepers 080200 Lanscaping Timbers 080201 Garden sheds 080202 Trellis and plant support 080203 Fencing material 080204 Pergolas …
USER MANUAL - Westinghouse Outdoor Power
cdn.westinghouseoutdoorpower.com• Never operate the generator in highly conductive areas such as around metal decking or steel works. • Always use grounded extension cords. Always use three-wire or double-insulated power tools. • Never touch live terminals or bare wires while the generator is operating. • Be sure the generator is properly grounded before operating.
Expansion Joints: Where, When and How
www.aisc.orgstruction Council Technical Report No. 65: Expansion Joints in Buildings (no longer in print). When other conditions prevail, the following rules are applicable: 1. If the building will be heated only and will have hinged-column bases, use the allowable length as specified. 2. If the building will be air conditioned as well as heated, increase ...
Stramit Patio Roofing Spans Table
www.stramit.com.auConcealed Fixed Decking Important Notice Foot traffic loads The tables show maximum spans (mm) for patio applications, with limited foot traffic load. During installation and maintenance, boards or ladders should be placed appropriately to distribute load. Stramit strongly recommends that measures be taken to
Decking Installation & Maintenance Guide
www.timbertech.comcare and cleaning, technical information and more. Color and Grain Patterns TimberTech decking is designed to mimic the look of real wood, and like real wood, there will be a slight difference in color and grain pattern from board to board. This is intentional and part of the manufacturing process, giving TimberTech decking the most