Technical Information Waterpilot FMX21 - Endress+Hauser
Options Drinking water approval • Large selection of approvals, including ATEX, FM, CSA • Broad range of accessories • Integrated Pt100 temperature sensor and TMT182 temperature head transmitter (4 to 20 mA HART) • Marine certificate Specialties • High-precision, robust ceramic measuring cell with long-term stability
Download Technical Information Waterpilot FMX21 - Endress+Hauser
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Technical Information iTEMP HART TMT182 - …
portal.endress.comTechnical Information iTEMP ... Operating elements At the temperature transmitter no ope rating elements are available direct ly. The temperature transmitter will
Information, Technical, Temperatures, Transmitter, Elements, Technical information, Temperature transmitter
IECEx Certificate of Conformity - Endress+Hauser
portal.endress.comIECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex…
Certificate, Conformity, Iecex, Iecex certificate of conformity
Technical Information Proline t-mass 65F, 65I
portal.endress.comProline t-mass 65F, 65I 4 Endress+Hauser Input Measured variable •Ma fssolw • Gas temperature • Gas heat flow Measuring range (air at ambient conditions) The measuring range is dependant on the gas selection, line size and use of flow conditioner.
Cerabar M PMC51, PMP51, PMP55 (Technische Information)
portal.endress.comCerabar M PMC51, PMP51, PMP55 6 Endress+Hauser Terms and abbreviations Term/abbreviation Explanation MWP The MWP (maximum working pressure) for the individual sensors depends on the lowest-rated element, with regard to
Technical Information Proline Promag 50W, 53W
portal.endress.comProline Promag 50W, 53W Endress+Hauser 3 Function and system design Measuring principle Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the flowing medium is the moving conductor.
Information, Technical, Promag, Proline, Proline promag 50w, Technical information proline promag 50w
Technical Information Proline t-mass 65F, 65I
portal.endress.comProline t-mass 65F, 65I 4 Endress+Hauser Function and system design Measuring principle The thermal principle operates by monitoring the cooling effect of a gas stream as it passes over a
Technical Information Liquiphant M FTL50, FTL51, FTL50H ...
portal.endress.comElectronic versions FEL51: Two-wire AC version; Switches the load directly into the power supply circuit via an electronic switch. FEL52: Three-wire DC version; Switches the load via the transistor (PNP) and separate connection e.g. in conjunction with programmable logic controllers (PLCs), DI modules as per EN 61131-2. FEL54:
Soliphant M FTM50, FTM51, FTM52
portal.endress.com• Switch the loads via 2 floating change-over con-tacts (DPDT) ... FEM52 electronic insert (DC PNP) Power supply • DC voltage: 10 to 55 V • Ripple: max. 1.7 V, 0 to 400 Hz ... Preferably used with programmable logic controllers (PLC), DI modules as per EN 61131-2.
Electronic, Load, Programmable, Soliphant, Soliphant m ftm50, Ftm50, Ftm51, Ftm52
Operating Instructions Flowphant T DTT31, DTT35
portal.endress.comDL Clamp 2" (ISO 2852) or DN 50 (DIN 32676) LB Varivent F DN25-32, PN 40 LL Varivent N DN40-162, PN 40 HL APV-Inline, DN50, PN40, 316L, B = bores 6 x Ø8.6 (0.34 in) + 2 x thread M8 PL DIN 11851, DN50, PN40 (including coupling nut) PG …
Operating, Instructions, Operating instructions, 32676, Din 32676
Liquisys M CPM223/253 - Endress+Hauser
portal.endress.comTemperature: adjustable, 10 to 100 % of upper range value Output voltage: 15 V ± 0.6 Output current: max. 10 mA Switching current with ohmic load (cos = 1): max. 2 A Switching current with inductive load (cos = 0.4):max. 2 A Switching voltage: max. 250 V AC, 30 V DC Switching power with ohmic load (cos = 1): max. 500 VA AC, 60 W DC
Related documents
Colt Series C300 (Colt 300), C300N (Colt 300N)
media.wattswater.comwater for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.! WARNING NOTICE The information contained herein is not intended to replace the The Colt C300, C300N Double Check Detector Assemblies
Series, Water, Colt, Drinking, N300, 300c, Series c300, Colt 300, C300n, Colt 300n
Series 009 - Plumbing, Heating and Water Quality Solutions
media.wattswater.com†Does not indicate approval status. Refer to Page 2 for approved sizes & models. 009QT-S 009M2QT Test Cock No. 3 Test Cock No. 4 R.P. Zone Water Outlet Test Cock No. 2 First Check Module Module Assembly Second Check Relief Valve Assembly Ball Type Test Cocks Now Available WattsBox Insulated Enclosures. For more information, send for ...
Series 9D - Plumbing, Heating and Water Quality Solutions
media.wattswater.comthrough the vent port thereby safeguarding the potable water system. Construction is brass body with stainless steel work-ing parts, integral strainer and durable rubber discs. Female union inlet and outlet connections. Sizes 1⁄2" and 3⁄4". Drain is 1⁄2" thread connection. Features • True line-sized construction allows the check modules ...
R9-8 Food Recreational and Institutional Sanitation ...
www.azdhs.gov8-203 Construction Inspection and Approval 165 8-3 LICENSE TO OPERATE 167 8-301 Requirement 167. viii ... Milk and milk products, which shall comply with A.R.S. Title 3, 2 Chapter 4 and A.A.C. Title 3, Chapter 2, Article 8; ... "Beverage" means a liquid for drinking, including water. (7) "Bottled drinking water" means water that is SEALED in ...
Product, Food, Construction, Sanitation, Water, Recreational, Institutional, Approval, Drinking, Drinking water, Food recreational and institutional sanitation
Cerabar M PMC51, PMP51, PMP55 (Technische Information)
portal.endress.comTI00436P/00/EN/19.14 Products Solutions Services No. 71260300 Technical Information Cerabar M PMC51, PMP51, PMP55 Process pressure measurement Pressure transmitter with ceramic and metallic sensors Application The device is used for the following measuring tasks: • Absolute pressure and gauge pressure measur ement in gases, steams or liquids ...
Spill Prevention, Control, and Countermeasure (SPCC ...
www.epa.govOil spills endanger public health, impact drinking water, devastate natural resources, and disrupt the economy. In the United States we use vast quantities of oils to heat our homes, provide fuel for automobiles, and operate various pieces of equipment. During storage, transport, or as the result of energy exploration and production activities, oil
Driven Point (Sand-point) Wells - Wisconsin Department of ...
dnr.wi.govallow water to flow through it into a well. Depth to the water table is another very important consideration when installing a driven point well. Although 1-1/4” diameter well pipe can be used when the water table is less than about 20’ below the ground surface, 2” diameter pipe must be used when the water Figure 1. Major areas of sand and
Water, Points, Well, Sand, Driven, Driven point, Sand point
American National Standards
share.ansi.orgIt is the purpose of this Standard to establish minimum requirements for materials, design and construction, and performance of point-of-use and point-of-entry drinking water treatment systems that are designed to reduce specific health-related contaminants in public or private water supplies.
Ultramid (PA) - Brochure - BASF
www.basf.comused in areas in which approval issues play a crucial role. For example, there are special products for applications with food contact. ULtRamId®NFoR I dUStRIaL PRodUctS aNd coNSUmER goodS The varied and in some cases tailor-made properties result in extensive application areas: construction and installation engineering
Label-Taurus SC 53883-279 MASTER 11-4-11 3 - …
www.epestsupply.comTaurus SC is formulated as a water-based suspension concentrate liquid containing 9.1% active ingredient. Mixing Instructions To mix Taurus SC termiticide / insecticide: 1. Fill the tank 1/4 to 1/3 full with water. The filling hose must be equipped with an anti-backflow device or water flow must include an air gap to protect against back ...