Technical Solution Sheet 0 - VBA
Technical Solution Sheet 0.04 Updated February 2016 www.vba.vic.gov.au . Page 3 of 6. FIGURE 2 – SOLUTION TO STORMWATER DRANAGE ON URBAN ALLOTMENT
Download Technical Solution Sheet 0 - VBA
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
VBA POOL AND SPA SAFETY BARRIER SELF-ASSESSMENT …
www.vba.vic.gov.auQUESTIONS YES NO DIAGRAM STEP 1 – BARRIER OBJECTIVE: SWIMMING POOLS AND SPAS MUST BE SURROUNDED BY A BARRIER RESTRICTING UNSUPERVISED ACCESS BY YOUNG CHILDREN. a) If your pool or spa barrier was approved between 8 April 1991 and 31 October 1994, complete Steps 2, 3 and 8. b) If your pool or spa barrier was approved between 1 November 1994 …
Owner-Builder - Information and Study Guide
www.vba.vic.gov.au3. An owner-builder is someone who takes responsibility for domestic building work carried out on their land and is legally responsible for the project from start to finish.
Drainage Below Ground Stormwater Sizing Drains and …
www.vba.vic.gov.aucalculations. (see Appendix A) SAA/SNZ HB114 for example calculations for typical roof styles. (see page 14 step 2) for the method using the slope factor for a pitched roof to an eaves gutter (hip & valley with no abutting vertical walls or flat roofs). The catchment area of a roof and any
Methods, Stormwater, Roof, Appendix, Sizing, Ground, Below, Drainage, For oa, Drainage below ground stormwater sizing
Bushfire Attack Level Assessment Report
www.vba.vic.gov.au• a non-habitable building being a private garage, carport, shed, or the like. Class 2 • a building containing 2 or more sole-occupancy units, each being a separate dwelling. Class 3 • a residential building, other than a building of Class 1 or 2, which is a …
3: Drainage (below ground sewer)
www.vba.vic.gov.au3: Drainage (below ground sewer) Updated June 2014 www.vba.vic.gov.au Page 1 of 6 Property Sewerage Drains AIM The aim of this technical solution is to inform practitioners about some of the requirements for below ground sanitary drains. This technical solution may be read in conjunction with the
Ground, Below, Sewer, Drainage, Below ground, Below ground sewer
Plumbing Fact Sheet: Overflow provision for box gutters
www.vba.vic.gov.auAs an alternative, the top of the rainhead may be installed so that it is no higher than 50 per cent of the flow depth of the box gutter, consistent with SAA HB39 Installation code for metal roof and wall cladding Section 5 Clause 5.7.3, and Figure 5.7.3 to prevent internal flooding or damage to the building or contents (see Figure 2).
Provisions, Alternatives, Gutter, Overflow, Overflow provision for box gutters
CERTIFICATE OF COMPLIANCE FOR PROPOSED BUILDING …
www.vba.vic.gov.auApproved by the Victorian Building Authority Page 1 of 3. ... or part of the design, set out in the documents listed above. (delete if peer review) I certify that the design set out in the documents listed above complies with the provisions set out above.
Guide to Standards and Tolerances (currently under review)
www.vba.vic.gov.au3.05 Blending and matching of masonry – repair work 30 3.06 Blending and matching of masonry – new work 30 3.07 Masonry facing 31 3.08 Mortar for masonry 31 3.09 Voids and holes in mortar 31 3.10 Cracked masonry unit 31 3.11 Cleaning, mortar smears and stains 31
Installation of Fixtures for Disabled Persons Building ...
www.vba.vic.gov.auof the WC pan has been taken as the datum plane The dimensions of 800 mm plus or minus 10mm from the front of the WC pan to the wall is a critical dimension. Technical Solution Sheet 1.04 Updated June 2014 ... FIGURE 4 – GRADES FOR BATHROOM AND SHOWER FLOORS (SOURCE: AS 1428.1)
Installation, Building, Persons, Disabled, Shower, Fixtures, Installation of fixtures for disabled persons building
Information sheet: Minimising foundation movement and ...
www.vba.vic.gov.auMinimising!foundation!movement! and!damage!to!your!house! Issued!August!2015! www.vba.vic.gov.au+ + Page+1+of+5+ Onceyouhavetakenownershipofyournewhome ...
Related documents
ENCROACHMENT ON PROPERTY BY-LAW - …
www.bvm.gov.za(7) Until the Council is notified of the horizontal dimension of the encroachment in terms of subsection (4)(b), every encroachment relating to a building is deemed to have an aggregate horizontal
Residential Concrete Driveways and Paths - Elvin …
www.elvingroup.com.auPage 2 of 12 > RESIDENTIAl Concrete Driveways and Paths 1 INTRODUCTION tasiche b function of residential pavements such as driveways, paths and patios = 6.25%is to provide safe, easy access onto or around a property.
Residential, Concrete, Driveway, Path, Residential concrete driveways and paths
Safety during tyre inflation in motor vehicle repair
www.hse.gov.ukHealth and Safety Executive Safety during tyre inflation in motor vehicle repair Health and Safety Executive Safety during tyre inflation in motor vehicle repair
Vehicle, Safety, During, Repair, Motor, Inflation, Tyres, Safety during tyre inflation in motor vehicle repair
Kerbs - Technicrete
www.technicrete.co.za1000 125 180 300 150 1000 62 180 300 75 62 180 300 75 1000 75 120 300 100 75 12 0 300 100 125 180 300 150 75 140 280 180 300 X 125 x 100 Mountable Kerb ( fig C900 ) 250 X 125 Barrier Kerb