Variable Air Volume (VAV) Controller Technical Bulletin
Table 1: VAV Controller Model Features Feature VAV100/101 (Discontinued) VAV110/111 VAV140/141 Ambient Temperature Rating 32 to 122°F (0 to 50°C) 32 to 122°F (0 to 50°C) 32 to 122°F (0 to 50°C) Analog Inputs 6 RTD temperature elements (1000 ohm nickel, platinum, or silicon) 2k ohm setpoint potentiometers 0 to 10 VDC or 0 to 2 VDC
Download Variable Air Volume (VAV) Controller Technical Bulletin
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
MODEL YK CENTRIFUGAL LIQUID CHILLER STYLE G
cgproducts.johnsoncontrols.comFORM 160.75-EG1 (517) MODEL YK CENTRIFUGAL LIQUID CHILLER STYLE G 250 THROUGH 3000 TONS (879 through 10,500 kW) Utilizing HFC-134a Refrigerant
Model, Liquid, Styles, Centrifugal, Model yk centrifugal liquid chiller style, Chiller
AIR-COOLED SCREW LIQUID CHILLERS - Johnson …
cgproducts.johnsoncontrols.comr134a ycav style a models ycav0157-0267, 60 hz (150-260 tons) e/v high efficiency and s/p standard efficiency ld10477 air-cooled screw liquid chillers
Liquid, Screw, Chiller, Cooled, Air cooled screw liquid chillers
MODEL YK (STYLE E) R-134a COOLING ONLY WITH …
cgproducts.johnsoncontrols.comoperating & maintenance maxetm centrifugal liquid chillers supersedes: nothing form 160.54-o2 (1102) model yk (style e) r-134a cooling only with optiviewtm control center for electro-mechanical starter,
With, Model, Liquid, Styles, Centrifugal, Model yk, Style e, R 134a cooling only with, 134a, Cooling, Only, Centrifugal liquid
Section Vb1: Valves - Johnson Controls
cgproducts.johnsoncontrols.comVb1 Engineering Data Book 3 Valves The valve is a controlled device that regulates the flow of a liquid or gas in a system. This regulation is accomplished by …
G670 Intermittent Pilot Ignition Controls Technical …
cgproducts.johnsoncontrols.comG G670 Intermittent Pilot Ignition Controls Technical Bulletin 3 Figure 2 illustrates the sequence of operation for the G670 ignition control. On a call for heat from the system thermostat, the G670 simultaneously
Control, Technical, Pilots, G670 intermittent pilot ignition controls technical, G670, Intermittent, Ignition
AIR-COOLED SCREW LIQUID CHILLERS - Johnson …
cgproducts.johnsoncontrols.com2 JOHNSON CONTROLS FORM 201.21-RP1 (616) In complying with YORK's policy for continuous improvement, the information contained in this document is subjected to change without notice.
Control, Liquid, Screw, Chiller, Cooled, Air cooled screw liquid chillers
MODELS SSS 7L-B, 14L-B, 26L-B, 33L-B ... - Johnson …
cgproducts.johnsoncontrols.com2 JOHNSON CONTROLS FORM 160.00-O2 ISSUE DATE: 6/10/2011 This equipment is a relatively complicated apparatus. During installation, operation maintenance or service,
A99B Series Temperature Sensors …
cgproducts.johnsoncontrols.com2 A99B Series Temperature Sensors Product/Technical Bulletin Application Overview IMPORTANT: All A99B Series Sensors are designed for use only with operating controls. Where an operating control failure would result in personal injury and/or
Product, Series, Technical, Temperatures, Sensor, A99b series temperature sensors, A99b, A99b series temperature sensors product
System 350TM A350P Electronic Proportional Plus …
cgproducts.johnsoncontrols.comReduces inventory by encompassing temperature ranges required to support the majority of Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC/R) applications
System, Electronic, Plus, Proportional, System 350tm a350p electronic proportional plus, 350tm, A350p
Ranco® Refrigeration Cross-Reference Catalog Page
cgproducts.johnsoncontrols.comThe performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Catalog, Cross, Reference, Pages, Refrigeration, Refrigeration cross reference catalog page
Related documents
Lecture 2 Linear Regression: A Model for the Mean
www.columbia.eduU9611 Spring 2005 10 Least Squares Procedure The Least-squares procedure obtains estimates of the linear equation coefficients β 0 and β 1, in the model by minimizing the sum of the squared residuals or errors (e i) This results in a procedure stated as Choose β 0 and β 1 so that the quantity is minimized. yˆ i =β0 +β1xi 2 ( ˆ)2
MELSEC-F Series FX3G/FX3GE Main Units and Configuration
us.mitsubishielectric.comModel Number FX3G-24MR/DS FX3G-24MR/ES FX3G-24MT/DSS FX3G-24MT/DS FX3G-24MT/ESS FX3G-24MT/ES Stocked Item S S S S S S Certification UL • cUL • CE (EMC) Integrated Inputs/Outputs 24 24 24 24 24 24 Power Supply (V) 24VDC 100-240VAC 24VDC 24VDC 100-240VAC 100-240VAC Integrated Inputs 14 14 14 14 14 14 Integrated Outputs 10 10 …
Model Criminal Jury Instructions
www.courts.michigan.govModel Criminal Jury Instructions Michigan Supreme Court We are pleased to provide an electronic copy of the criminal jury instructions presently in use for criminal trials. On January 1, 2014, by Administrative Order 2013-13, the Michigan Supreme Court created the Committee on Model Criminal Jury Instructions. The
Mechanical System Elements
engineering.nyu.edu– A damper element is used to model a device designed into a system (e.g., automotive shock absorbers) or for unavoidable parasitic effects (e.g., air drag). – To be an energy-dissipating effect, a device must exert a force opposite to the velocity; power is always negative when the force and velocity have opposite directions.