WESTERN SPECIFIER GUIDE - Boise Cascade
Mar 14, 2013 · Boise Cascade EWP • Western Specifier Guide • 03/14/2013 Residential Floor Span Tables OneHour Fire Resistive Assembly FIRE ASSEMBLY COMPONENTS 1. 23Min. /32" thick tongue and groove sheathing (exterior glue), installed with long edge perpendicular to joist length, staggered one joist spacing with adjacent
Download WESTERN SPECIFIER GUIDE - Boise Cascade
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
WESTERN SPECIFIER GUIDE - Boise Cascade
www.bc.comArchitects, engineers, and designers trust Boise Cascade's engineered wood products
EASTERN SPECIFIER GUIDE - Boise Cascade
www.bc.comversa-lam® 2.0e eastern specifier guide vlesg may 2014. ... 5½ 1.09 8.4 10 049 13 574 146 2.0 6 270 580 5 300 1 525 7¼ 1.06 11.1 13 246 22 873 333 9¼ 1.03 14.2 16 900 36 239 692 9½ 1.03 14.5 17 357 38 112 750 11¼ 1.01 17.2 20 554 52 451 1 246 11⅞ 1.00 18.2 21 696 58 091 1 465
BOISE GLULAM 24F-V4 IJC GUIDE - Boise Cascade
www.bc.com556 1032 1615 2247 2936 874 1621 2537 3530 4614 493 794 1242 1729 2260 775 1247 1952 2717 3552 1.5 / 3 2.1 / 4 3.2 / 6.2 4.5 / 8.6 5.8 / 11.2 1.5 / 3 2.1 / 4 3.2 / 6.2 4.5 / 8.6 5.8 / 11.2 404 825 1306 1817 2376 635 1297 2052 2856 3733 398 …
IJ-12 Design Live Loads Residential Floors 2014 06
www.bc.comTech Note IJ-12 Page 1 of 1 r06/2014 (valid 2 years past publish date) Design Live Loads for Residential Floors U.S. building codes specify a uniform live load of 40 pounds per square foot (psf) for most residential floor designs. This load is intended to account for the large number of loads that can occur in a residence.
Design, Live, Residential, Floor, Load, 12 design live loads residential floors
Connecting Multiple-Ply 1 ¾” Versa-Lam Beams with ...
www.bc.com- Fastener values based upon FastenMaster ICC ESR report 1078 and Technical Bulletin 1. - Spacing Requirements For further information, please consult FastenMaster TrussLok Technical Bulletin 1. Technical Note Tech Note LVL-9 Page 2 of 2 r1/09 Connection Design Example
Related documents
Conduct Disorder 312.8x (F91.x) - images.pearsonclinical.com
images.pearsonclinical.comThus, to assess the criteria for the specifier, multiple information sources are necessary. In addition to the individual’s self-report, it is necessary to consider reports by others who have known the individual for extended periods of time (e.g., parents, teachers, co-workers, extended family members, peers).
A specifier's guide to LPG - Calor Gas
www.calor.co.ukA specifier's guide to LPG. Calor operates the only truly nationwide distribution network in the UK LPG industry. There are 16 strategically positioned bulk distribution depots, together with 11,000 cylinder stockists available for the smaller consumer.
TJI 110, 210, 230, 360, and 560 Joist Specifier's Guide
parr.com4 iLevel Trus Joist® TJI® Joist Specifier’s Guide TJ-4000 February 2008 How to Use These Tables 1 . Determine the appropriate live load deflection criteria . 2 . Identify the live and dead load condition . 3 . Select on-center spacing . 4 . Scan down the column until you meet or exceed the span of your application . 5 . Select TJI® joist ...
Stair Stringers and Treads Specifier's Guide
owenlumber.comTimberStrand ® LSL Stair Stringers and SturdiStep Stair Treads Specifier’s Guide 9010 |ember 2015Sept 2 1¼" 1.3E TimBERSTRand® LSL SAIRT STRINGERS Suggested Residential Stringer Attachment Details 40 psf Live Load and 12 psf Dead Load High End (1) Minimum throat depths may be reduced by an additional ¼" for 117⁄8" and 14" material depths if 2x4 reinforcement is
The DSM-5 MDD Anxious Distress Specifier: A Useful ...
isctm.orgspecifier (on-going) Need prospective evaluation with complete scale and genetic/biomarker data and treatment response The DSM-5 MDD Anxious Distress Specifier may be useful as a risk indicator in the evaluation of patients with MDD and subthreshold or premorbid anxiety
Understanding Raised Floor Systems for the Specifier
www.accessflooring.comSpecifier (2016) Unit 4 Enterprise Way Edenbridge Kent TN8 6EW United Kingdom. The Access Flooring Company – www.accessflooring.com Current Specifications European Raised Flooring Systems now fall into two main Specification Categories. Those being PSA MOB PF2 PS and the New European and UK British Standard
System, Understanding, Floor, Specifier, Raised, Understanding raised floor systems for
Specifier's Guide for Parallam Plus PSL
www.northeastco.comTrus Joist ® Parallam Plus PSL Specifier's Guide TJ-7102 |14June 20 3 pRoduCT FeaTuReS and SizeS in order for parallam® plus pSl to perform as described, the product must maintain its original cross section. parallam plus® beams, headers and columns may be cut to length, but must not be resawn in depth or thickness.
Using the Specifier - psychiatry.org
www.psychiatry.orgThe specifier goes beyond the presence of negative behavior and reflects an individual’s typical patterns in emotional and interpersonal functioning. People with conduct disorder who show this specifier display limited empathy and little concern for …
Using the Specifiers - psychiatry.org
www.psychiatry.orgspecifier will require the presence of at least three symptoms of depression in concert with the episode of mania/hypomania. Using the Specifiers. If an individual is predominantly manic or hypomanic but also presents with depressive symptoms, the mixed features specifier may be considered. Depressive symptoms may include depressed mood,