Example: tourism industry

AXF Series Magnetic Flowmeter Installation Manual

User sManualContents1. Using the Magnetic Flowmeter Safely .. Warranty .. Combination for Flowtube and remote Converter ..42. Handling Checking Model and Specifications .. Storage Precautions ..53. Piping Design Precautions .. Handling Precautions .. Installation of Integral Flowmeter and remote Flowtube .. Installation of remote Converter ..274. Wiring the Integral Flowmeter .. Wiring the remote Flowtube .. Wiring the AXFA14 remote Converter .. Wiring the AXFA11 remote Converter ..465. Basic Operating Operating Procedures Using the Display Unit .. Operating Panel Configuration and Display Unit Setting Methods.

AXF Magnetic Flowmeter Integral Flowmeter/ Remote Flowtube [Hardware Edition] IM 01E20C01-01E AXFA11G Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] IM 01E20C02-01E AXFA14G/C Magnetic Flowmeter Remote Converter [Hardware Edition/Software Edition] AXF Magnetic Flowmeter Integral Flowmeter [Software Edition] GS …

Tags:

  Remote, Relating, Flowmeter, Magnetic, Magnetic flowmeter, Flowtubes, Magnetic flowmeter integral flowmeter, Magnetic flowmeter integral flowmeter remote flowtube, Magnetic flowmeter remote

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of AXF Series Magnetic Flowmeter Installation Manual

1 User sManualContents1. Using the Magnetic Flowmeter Safely .. Warranty .. Combination for Flowtube and remote Converter ..42. Handling Checking Model and Specifications .. Storage Precautions ..53. Piping Design Precautions .. Handling Precautions .. Installation of Integral Flowmeter and remote Flowtube .. Installation of remote Converter ..274. Wiring the Integral Flowmeter .. Wiring the remote Flowtube .. Wiring the AXFA14 remote Converter .. Wiring the AXFA11 remote Converter ..465. Basic Operating Operating Procedures Using the Display Unit .. Operating Panel Configuration and Display Unit Setting Methods.

2 Parameter Setting Procedure .. BRAIN / HART Connection ..576. Pre-operation Zero Adjustment .. Zero Adjustment Using Display Unit Switches .. Write Protect Switch ..607. Errors and Countermeasures for Display unit and BRAIN protocol8. Parameter Menu tree for DD (HART 5) .. Parameter List (BRAIN) ..679. Approvals10. Explosion Protected Type ATEX .. FM .. CSA .. IECEx .. TIIS ..82 Installation AND OPERATING PRECAUTIONS FOR TIIS FLAMEPROOF EQUIPMENTN otes for the Identification Tag12345679810 AXF SeriesMagnetic FlowmeterInstallation ManualIM 01E20A01-01 ENIM 01E20A01-01EN4th EditionIntegral Flowmeter (AXF G, AXF C, AXF H) remote Converter (AXFA14G, AXFA14C) remote Flowtube (AXF G, AXF C, AXF H, AXF W) remote Converter (AXFA11G)This Manual outlines the basic guidelines for Installation and wiring procedures of the ADMAG AXF Series .

3 For the items which are not covered in this Manual , see the user s manuals in the following : For FOUNDATION fieldbus and PROFIBUS PA type, refer to IM 01E20A01-02EN in addition to this Manual . For ATEX or IECEx explosion proof type, refer to IM 01E20A01-11EN in addition to this TitleIM 01E20D01-01 EAXF Magnetic Flowmeter Integral Flowmeter / remote Flowtube [Hardware Edition]IM 01E20C01-01 EAXFA11G Magnetic Flowmeter remote Converter [Hardware Edition/Software Edition]IM 01E20C02-01 EAXFA14G/C Magnetic Flowmeter remote Converter [Hardware Edition/Software Edition]AXF Magnetic Flowmeter Integral Flowmeter [Software Edition]GS 01E20S00-01 ENADMAG Series Magnetic Flowmeter List of RoHS (2011/65/EU) Directive Compliant Products <1.

4 Introduction>1IM 01E20A01-01EN4th Edition: July 2021 (KP)All Rights Reserved, Copyright 2014, Yokogawa Electric Corporation1. IntroductionThank you for purchasing the ADMAG AXF Magnetic Manual provides the basic guidelines for Installation and wiring procedures of integral Flowmeter , remote flowtube, and remote converter of the AXF Magnetic flowmeters through front panel, BRAIN protocol, and HART does not provide the product specific functional specifications and explanations, maintenance, troubleshooting, FOUNDATION fieldbus and PROFIBUS PA communication operating procedures. For the items which are not covered in this Manual , see the applicable user s manuals as listed in Table These manuals can be downloaded from the website of Yokogawa.

5 To ensure correct use of the instrument, read these manuals thoroughly and fully understand how to operate the instrument before operating it. For method of checking the model and suffix code, refer to Section address: Manual ListModelDocument TitleDocument GAXF CAXF HAXF WAXF Magnetic Flowmeter Integral Flowmeter / remote Flowtube [Hardware Edition]IM 01E20D01-01 EAXFA14G/C Magnetic Flowmeter remote Converter [Hardware Edition/Software Edition]AXF Magnetic Flowmeter Integral Flowmeter [Software Edition]IM 01E20C02-01 EAXFA11 GAXFA11G Magnetic Flowmeter remote Converter [Hardware Edition/Software Edition]IM 01E20C01-01 EAXFA14 GAXFA14 CAXFA14G/C Magnetic Flowmeter remote Converter [Hardware Edition/Software Edition]AXF Magnetic Flowmeter Integral Flowmeter [Software Edition]

6 IM 01E20C02-01 EIn case of selecting the communication code (The first two characters of suffix code) -F , further refer to the following TitleDocument G AXF C AXF H AXF W AXFA14G AXFA14C-FADMAG AXF Series FOUNDATION Fieldbus Communication TypeMagnetic FlowmeterIM 01E20F02-01 EIn case of selecting the communication code (The first two characters of suffix code) -G , further refer to the following TitleDocument G AXF C AXF H AXF W AXFA14G AXFA14C-GAXF PROFIBUS PA Communication TypeMagnetic FlowmeterIM 01E20F12-01 ENote: means any of the following. 002, 005, 010, 015, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400 NOTEWhen describing the model name like AXF C in this Manual , means any of the , 005, 010, 015, 025, 032, 040, 050, 065, 080, 100, 125, 150, 200, 250, 300, 350, 400 Safety and Modification Precautions The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument.

7 Failure to comply with these precautions or with specific WARNINGS given elsewhere in this Manual violates safety standards of design, manufacture, and intended use of the instrument. Yokogawa assumes no liability for the customer s failure to comply with these requirements. If this instrument is used in a manner not specified in this Manual , the protection provided by this instrument may be impaired. Yokogawa will not be liable for malfunctions or damage resulting from any modification made to this instrument by the customer. The following safety symbol marks are used in this user s Manual and A WARNING sign denotes a hazard.

8 It calls attention to procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury or death of CAUTION sign denotes a hazard. It calls attention to procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the <1. Introduction>2IM 01E20A01-01 ENIMPORTANTAn IMPORTANT sign denotes that attention is required to avoid damage to the instrument or system NOTE sign denotes information necessary for essential understanding of operation and grounding terminalFunctional grounding terminal(This terminal should not be used as a protective grounding terminal.)

9 Alternating currentDirect currentCautionThis symbol indicates that the operator must refer to an explanation in the user s Manual in order to avoid the risk of injury or death of personnel or damage to the instrument. Regarding This User s Manual This Manual should be provided to the end user. Before use, read this Manual thoroughly to comprehend its contents. The contents of this Manual may be changed without prior notice. All rights are reserved. No part of this Manual may be reproduced in any form without Yokogawa s written permission. Yokogawa makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of merchantability and suitability for a particular purpose.

10 All reasonable effort has been made to ensure the accuracy of the contents of this Manual . However, if any errors or omissions are found, inform Yokogawa. Yokogawa assumes no responsibilities for this product except as stated in the warranty. Note that this user s Manual may not be revised for any specification changes, construction changes or operating part changes that are not considered to affect function or performance. If the customer or any third party is harmed by the use of this product, Yokogawa assumes no responsibility for any such harm owing to any defects in the product which were not predictable, or for any indirect damages.