Example: bankruptcy

2-Wire Current Transmitter, 4-20 mA Output - CR …

851015203050751001502003004000-50-100-15 0-200-300-500-750-1000-1500-2000-3000-40 01111111111222- wire Current Transmitter, 4-20 mA OutputFeaturesSpecificationsPermanently calibratedLoop-poweredFully isolated12 different ranges2 case styles, .93 ( mm) and ( mm)window openingOutput overload protectedAccuracy: Full-Scale (FS)Repeatability:Less than & Noise:1% Max., peak to peak Calibrated Signal Out: 4-20 mA DCResponse Time:200 ms max., 10-90% FSMax. Signal Out:30 mA DCTemperature Coefficient: CSupply Voltage:24 Vdc 10% Frequency:50/60 HzContinuous Thermal Current Rating @ 30 C Short Time Thermal Current Rating Factor (For 30 Seconds) x Full Scale for AC ranges up to 200 x Full Scale for ranges 300 and 400 Amp. Output Load:0 to 600 ohmsInsulation Class:600 V, BIL 10 kV Full WaveReverse Polarity Protection:YesOperating Temperature Range:-30 C to +60 CStorage Temperature Range:-55 C to +85 CApproximate pounds (.)

8 5 10 15 20 30 50 75 100 150 200 300 400 0-5 0-10 0-15 0-20 0-30 0-50 0-75 0-100 0-150 0-200 0-300 0-400 1 1 1 1 1 1 1 1 1 1 2 2 2-Wire Current Transmitter, 4 …

Tags:

  Current, Wire, Wire current

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 2-Wire Current Transmitter, 4-20 mA Output - CR …

1 851015203050751001502003004000-50-100-15 0-200-300-500-750-1000-1500-2000-3000-40 01111111111222- wire Current Transmitter, 4-20 mA OutputFeaturesSpecificationsPermanently calibratedLoop-poweredFully isolated12 different ranges2 case styles, .93 ( mm) and ( mm)window openingOutput overload protectedAccuracy: Full-Scale (FS)Repeatability:Less than & Noise:1% Max., peak to peak Calibrated Signal Out: 4-20 mA DCResponse Time:200 ms max., 10-90% FSMax. Signal Out:30 mA DCTemperature Coefficient: CSupply Voltage:24 Vdc 10% Frequency:50/60 HzContinuous Thermal Current Rating @ 30 C Short Time Thermal Current Rating Factor (For 30 Seconds) x Full Scale for AC ranges up to 200 x Full Scale for ranges 300 and 400 Amp. Output Load:0 to 600 ohmsInsulation Class:600 V, BIL 10 kV Full WaveReverse Polarity Protection:YesOperating Temperature Range:-30 C to +60 CStorage Temperature Range:-55 C to +85 CApproximate pounds (.)

2 68 kg)The CR4320series, loop-powered, 2-Wire CurrentTransmitter produces a calibrated 4-20 mA. DC Output Current directly proportional to the averageRMS value of the input alternating Current . The controlled Current Output is unaffected by variations in supply voltage, interconnect and load impedance(within specification limits) to provide a highly accu-rate means for monitoring alternating Current overlong NumbersCR4320 - qqq4-20 MA Current TRANSMITTERFull-Scale (FS)Range in AC AmpsCaseStyle Case Style 1 Case Style 2 E154235 Internet Resources Selection Guide: Sheet: : Loads: Magnetics, Inc. 544 Axminister Dr. Fenton MO USA 63026 V: F: : : Notes2- wire Current Transmitter4-20 mA ( ) ( ) ( ) ( ).50 ( ) (60) ( ).25 ( )# 10-32(Use M4 terminals).93 ( ) ( ).

3 15 ( ).50 ( ) ( ) ( ).44 ( ) TYP.#8-32(Use M4 terminal) ( ) (38) ( )DIA. LOOP Current OUTVSFULL-SCALE INPUT CURRENTCase Style 1 Case Style 2 Typical ApplicationsAn external Current transformer may be used with the transmitter by routing the secondary leads through the window opening. Use the CR4320-5 Current transmitter when using a 5 Amp secondary instrument grade Current transformer. For additional details on Current transformers, see page scaling factor may be changed by threading the primary Current -carrying wire several times through the window opening. The "actual" measurement range will be the name plate range divided by the number of wire passes. For example, the CR4320-30 has the name plate range of 0-30 Aac. Two passes of the wire through the window opening will then provide an effective range of 0-15 Aac (30 2).

4 In (mm) +-0 to 600 ohmsI INPUT I PRIMARYI CONTROLI LOOPX 1624 Vdc+ 4FS INTERCONNECTRESISTANCEINSTRUMENTATIONRES ISTANCEFS = FULL-SCALE Current IN AMPS RMSI PRIMARY = MONITORED Current IN AMPS RMSI LOOP= LOOP Current IN mA dcI LOOPCr4320-30 Percentage Full Scale (FS)Loop Current DC MA0-15 Aac