Example: dental hygienist

Fire Pump Test Report - FPE Software

FPE Software , Box 1748 Prince Frederick, MD 20678410-586-2128410-586-2085 faxFire Pump TestReportConducted Paint Company40 Washington Street7/31/2001 Maplewood, MD 20678 ABC Paint CompanyFIRE PUMP TEST REPORTC ompanyABC Paint CompanyName: 40 Washington StreetAddress: City/St/Zip: Maplewood, MD 20678 Contact Name: Kenney McRicklesTitle: Facilities ManagerDept: Facilites ManagementPhone: Ext: 410-555-1234 Pump ControllerManufacturer: FiretrolUL/FMLabel: Model Number: FTA 750-AA30 HSerial Number: 117400On Pressure: psiOff Pressure: psiRun Timer: mins9010010 AutoTest Freq: Auto Test On: Auto Test Off: Weekly7:00 am7:30 amJockey PumpManufacturer: BurkesFMLabel: Model Number: 37CT7 MSerial Number: 368313 Horsepower: RPM: Flow: : psiSuction Diam: Discharge Diam: in inDiesel DriverAjax TEFCM anufacturer: ULLabel: Model Number: RB-30-2-8577123465789 Serial Number: Horsepower: RPM: # cylinders: 3017508 Outside north wall of pump house300 Fuel Tank Location: Gallons: PumpManufacturer: Reddy BuffaloeLa

FPE Software, Inc. P.O. Box 1748 Prince Frederick, MD 20678 410-586-2128 410-586-2085 fax Fire Pump Test Report Conducted by: mail@fpesoftware.com www.fpesoftware.com

Tags:

  Report, Tests, Pumps, Fire, Fire pump test report

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Fire Pump Test Report - FPE Software

1 FPE Software , Box 1748 Prince Frederick, MD 20678410-586-2128410-586-2085 faxFire Pump TestReportConducted Paint Company40 Washington Street7/31/2001 Maplewood, MD 20678 ABC Paint CompanyFIRE PUMP TEST REPORTC ompanyABC Paint CompanyName: 40 Washington StreetAddress: City/St/Zip: Maplewood, MD 20678 Contact Name: Kenney McRicklesTitle: Facilities ManagerDept: Facilites ManagementPhone: Ext: 410-555-1234 Pump ControllerManufacturer: FiretrolUL/FMLabel: Model Number: FTA 750-AA30 HSerial Number: 117400On Pressure: psiOff Pressure: psiRun Timer: mins9010010 AutoTest Freq: Auto Test On: Auto Test Off: Weekly7:00 am7:30 amJockey PumpManufacturer: BurkesFMLabel: Model Number: 37CT7 MSerial Number: 368313 Horsepower: RPM: Flow: : psiSuction Diam: Discharge Diam: in inDiesel DriverAjax TEFCM anufacturer: ULLabel: Model Number: RB-30-2-8577123465789 Serial Number: Horsepower: RPM: # cylinders: 3017508 Outside north wall of pump house300 Fuel Tank Location: Gallons: PumpManufacturer: Reddy BuffaloeLabel: ULModel Number: 6x6 DFSerial Number: 845-136-DF6 Pump Type: HorizontalRPM: 1750 Rating - Churn: 0 gpm @ 60 psi7501, : gpm @ gpm @ psi psi100%: Elevations - Pump: ftDischarge Gauge: ft1 Suction Gauge: ft1 Diameters - Impeller: Pipe: in6 Suction Pipe: in6 Inner Bearing: Outer Bearing.

2 32513450 Rotation: Max. Discharge Pressure: psiClockwise230 Driver Type: DieselFire Pump Evaluation Program 2002 Page 2 FPE Software , Paint CompanyFIRE PUMP TEST REPORTF actory CurvePressure: Flow: , , gpm psiTestDate: Start: End: 7/31/200112:00:00 PM12:30:00 PMMethod: Discharge Device: Devices with hosePlaypipesSuction Pressure Location: Pump suction flangeDischarge Pressure Location: Pump discharge flangePump NotesJockey sensing line takeoff in wrong from packing glands not draining properly. Drain pipe may Angle GearManufacturer: Amarillo GearAMR-1234 Model Number: Serial Number: 12345-678 Ratio: 1x117501750 Input RPM: Output RPM: Transfer SwitchSerial Number: 123456798 Model Number: 789456-456 Manufacturer: Boone ElectricEmergency power Source: Diesel generatorTransfer Time: 1 secsRelief Valve(s) in psiPump Pressure - in Casing - Jockey Casing - in HorsepowerBrake Horsepower: BHP: at Positive Suction Pressure: 180 psiJockey Pump ControllerManufacturer: FiretrolLabel: ULModel Number: FTA 500-AA34H-XSerial Number: 117404On Pressure: psiOff Pressure.

3 Psi110135 fire Pump Evaluation Program 2002 Page 3 FPE Software , Paint CompanyFIRE PUMP TEST REPORTT ester(s)NameLicenseStateMark Lentocha, PE12345 MDJim Brown23456 MDTracy DuffeyBrent WallaceTemperaturesPump Bearing - Inner: 120 FOuter: F125 Driver Bearing - Inner: FOuter: F170180 Diesel FluidsFuel Tank - Start: End: Oil Level: Full7/8 FullWitness(es)Name: Tom DurossCompany: Two Guys InsurancePhone: Fax: 816-555-1456816-555-1232E-mail: Gary HeubeckCompany: Two Guys InsurancePhone: Fax: 816-555-1457816-555-1232E-mail: Having JurisdictionName: Howard PackerTitle: fire MarshallCompany: Torington fire DepartmentPhone: Ext: 410-555-1212 Fax: 410-555-7456 Cell: E-mail: Pump Evaluation Program 2002 Page 4 FPE Software , Paint CompanyFIRE PUMP TEST REPORTTest NotesTest went well - no problems & MetersTypeCalibration DatePressure Gauges: Nemco ACS-102 Digital1/15/2002 Volt Meter: Enrico Model 15612/15/2001 Amp Probe: Enrico Model 15812/15/2001 Tachometer: Accurate Model 238/6/2001 fire Pump Evaluation Program 2002 Page 5 FPE Software , Inc.