Search results with tag "Deluge"
Fire Equipment Supply, System Integrators, Design ... - Deluge
www.deluge.com.sgABOUT US DELUGE FIRE PROTECTION Deluge Fire Protection (S.E.A.) Pte Ltd started in Singapore in 1983. The company has adopted and practices the prefabricated construction method of fire installations since 1996.
ESD Deluge Functional Description - Electrical …
escventura.comEmergency Systems Location revised 02-02-05 A.Overview The Instrument Air System is a pneumatic system that supplies air for field instruments, the Shutdown Panel, the ESD System, and the Deluge/Fusible Plug System. The Shutdown Panel is a pneumatic panel located in the Deep Pit that allows for the automatic operation of control valves …
TECHNICAL DATA DELUGE SYSTEM - vikingcorp.com
www.vikingcorp.comTECHNICAL DATA April 17, 2009 DELUGE SYSTEM The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com
Solenoid Operated Deluge Valve - Cla-Val
www.cla-val.comSolenoid Operated Deluge Valve Schematic Diagram Item Description 1 100G/2100G UL/ULC Listed Hytrol Main Valve 2 CS3 Solenoid Control
MATERIAL SAFETY DATA SHEET - DKT
www.dkt.net.auV:\Sales & Marketing\Product Information\Adjuvants\Deluge\MSDS - LABELS\MSDSDeluge.doc REV: 2 REVISED: 5 May 2005 Page 1 of 3 VICTORIAN CHEMICAL CO. PTY. LTD.
SCALAR TAPE LIBRARIES DATASHEET
cdn.allbound.comData Archiving and Cyber Protection Disk Storage Nearline Cloud Copy O site/DR Archive File system or archive software moves files to tape archive Scalar Tape Library (Up to 540 PB*) On-prem tape for o•ine copy to manage data deluge and protect against cyber threats *Assuming 2.5:1 Compression Clients Applications Production Storage
Physical Access Control - HHS.gov
www.hhs.gov− Deluge: Allows greater volume of water to be released upon dispersal. Proper atmospheric conditions must be maintained for the proper maintenance of data assets. − High humidity levels (<60%) risk causing corrosion to equipment. − Low humidity levels (>20%) risk building static electricity, potential harming equipment.
Climate Change in South Asia: Strong Responses for ... - ADB
www.adb.orgDanger of Deluge Significant portions of Bangladesh, India, Nepal, and Sri Lanka are prone to recurrent flooding due to such factors as heavy monsoon rains, blocked natural drainage, and low elevation. Melting glaciers and rising seas with greater probability of flooding and storm surges caused by climate
Commercial Flexible SPK Tech Data - Viking Group Inc
www.vikinggroupinc.comFlexHead products are intended for use in hydraulically designed wet, pre-action, deluge or dry pipe sprinkler connections per NFPA 13, 13R, and 13D guidelines. The hydraulic loss of the FlexHead connector needs to be included in the hydraulic design calculations the …
HIGH VELOCITY WATER SPRAY NOZZLE - HD Fire
www.hdfire.comTECHNICAL DATA HIGH VELOCITY WATER SPRAY NOZZLE MODELS HV-AS & HV-BS MODEL HV-AS & HV-BS ... water spray or deluge system for the fire protection application. ... damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire s product liability exceed an amount equal to the sale price.
Automatic Sprinkler System Basics - International Fog
www.internationalfog.comNon-interlocked preaction system: Use: Non-interlocked preaction systems are used to protect unheated warehouses or small airplane hangars. Deluge system:Uses open sprinklers to deliver a large
READ SAFETY DIRECTIONS BEFORE OPENING OR …
www.vicchem.comWETTING AGENT DELUGE 1000 † ACTIVE CONSTITUENT: 950 g / L NON-IONIC FATTY ACID ETHOXYLATES A Bio-degradable, Nonionic wetting and spreading agent
GENERAL SPECIFICATION - 建築署
www.archsd.gov.hkA5.7 Operation And Maintenance Manuals ... B3.23 Recycling System B3.24 Deluge Installation B3.25 Drencher Installation ... SECTION B6 : MANUAL AND AUTOMATIC FIRE ALARM SYSTEM B6.1 Manual Call Points B6.2 Heat Detectors B6.3 Ionisation Smoke Detectors .
TECHNICAL DATA soLENoID vALvEs rATED To 250 psI (17.2 …
www.vikingcorp.comTECHNICAL DATA Deluge 273b JUne 5, 2013 soLENoID vALvEs rATED To 250 psI (17.2 bAr) The viking Corporation, 210 N Industrial park Drive, Hastings MI 49058
DOUBLE INTERLOCK, PREACTION SYSTEM
www.hdfire.comDouble Interlock Pre-Action System to automatical-ly actuate, two independent events must occur. The Deluge Valve Releasing Panel must operate and open the Solenoid Valve upon automatic operation of the electric fire detection initiating circuit and the sprin-kler system piping must lose air pressure due to op-eration of one or more sprinklers.
DELUGE VALVE MODEL-H3 - HD Fire
www.hdfire.comDeluge Valve is known as a system control valve in a deluge system, used for fast application of water in a spray system. Deluge valve protects areas such as power transformer installation, storage tank, conveyor protection and other industrial application etc. With the addition of foaming agent, deluge valve
Deluge Sprinkler Systems - Viking Corp
www.vikingcorp.comDeluge Sprinkler Systems Deluge sprinkler systems have open sprinklers or open spray nozzles and are used where it is desirable to discharge water through
Deluge System Technical Manual for Operation, …
www.vikinggroupinc.comJun 30, 2009 · Deluge System Technical Manual for Operation, Maintenance, and Troubleshooting. June, 2009. Form No. F_010708
Deluge System Technical Manual for Operation, …
www.vikinggroupinc.complex than wet pipe and dry systems because they contain more components and equipment. The deluge valve is activated by operation of a fire detection system installed in the same area as the sprinklers (Figure
Deluge System Technical Manual for Operation, …
www.vikingcorp.complex than wet pipe and dry systems because they contain more components and equipment. The deluge valve is activated by operation of a fire detection system …
DELUGE VALVE JOB NO. : DATA SHEET - Siemens
www.siemens.co.krJANUARY, 2006 PAGE OF 153 HD101 (iv) PERIODIC CHECK Conduct the water flow test by actuating few of the release devices provided in the system.
Similar queries
Fire Equipment Supply, System Integrators, Design, Deluge, ESD Deluge Functional Description, Automatic, TECHNICAL DATA DELUGE SYSTEM, TECHNICAL DATA, Deluge system, Solenoid Operated Deluge Valve, Valve, Data, System, Data deluge, Maintenance, Automatic Sprinkler System Basics, Systems, WETTING AGENT DELUGE 1000, GENERAL SPECIFICATION, Operation, Manual, TECHNICAL DATA soLENoID vALvEs rATED, DOUBLE INTERLOCK, PREACTION SYSTEM, Double Interlock Pre-Action System, Op-eration, Deluge Sprinkler Systems, Viking, Deluge Sprinkler Systems Deluge sprinkler systems, Deluge System Technical Manual for Operation,, Deluge System Technical Manual for Operation, Maintenance, Deluge valve, DELUGE VALVE JOB NO. : DATA SHEET, Test