Example: barber

MSDS P3 Oil Safety Data Sheet - Ideal Vac

Safety data SheetRevision date: 09-09-10 Print date: 09-10-30according to regulation 1907/2006 Identification of the Substance/Preparation and Company/UndertakingProduct name:P3 Uses:Lubricant/ Operating Fluid for Vacuum PumpsManufacturer/ Supplier:Pfeiffer Vacuum GmbH Berliner Strasse 43 D-35614 Asslar Telefon 06441/802-0 Telefax 06441/802-202 Tele-phone Hazards IdentificationEC Classification:Not classified as dangerous under EC Hazards:Not expected to be a health hazard when used under normalconditions. Prolonged or repeated skin contact without propercleaning can clog the pores of the skin resulting in disorderssuch as oil acne/folliculitis.

Safety Data Sheet Revision date: 09-09-10 according to regulation 1907/2006/EC Print date: 09-10-30 PK0001ME_E.fm P3 1 Identification of the …

Tags:

  Sheet, Data, Safety, Safety data sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MSDS P3 Oil Safety Data Sheet - Ideal Vac

1 Safety data SheetRevision date: 09-09-10 Print date: 09-10-30according to regulation 1907/2006 Identification of the Substance/Preparation and Company/UndertakingProduct name:P3 Uses:Lubricant/ Operating Fluid for Vacuum PumpsManufacturer/ Supplier:Pfeiffer Vacuum GmbH Berliner Strasse 43 D-35614 Asslar Telefon 06441/802-0 Telefax 06441/802-202 Tele-phone Hazards IdentificationEC Classification:Not classified as dangerous under EC Hazards:Not expected to be a health hazard when used under normalconditions. Prolonged or repeated skin contact without propercleaning can clog the pores of the skin resulting in disorderssuch as oil acne/folliculitis.

2 Used oil may contain and Sym-ptoms:Oil acne/folliculitis signs and symptoms may include formationof black pustules and spots on the skin of exposed may result in nausea, vomiting and/or Hazards:Not classified as flammable but will Hazards:Not classified as dangerous for the Composition/Information on IngredientsPreparation Descrip-tion:Highly refined mineral oils and Informa-tion:The highly refined mineral oil contains <3% (w/w) DMSO extract,according to data Sheet : P32 date: 09-10-30 4 First Aid MeasuresGeneral Information:Not expected to be a health hazard when used under :No treatment necessary under normal conditions of use.

3 Ifsymptoms persist, obtain medical Contact:Remove contaminated clothing. Flush exposed area with waterand follow by washing with soap if available. If persistentirritation occurs, obtain medical Contact:Flush eye with copious quantities of water. If persistent irritation occurs, obtain medical :In general no treatment is necessary unless large quantitiesare swallowed, however, get medical to Physician:Treat symptomatically. 5 Fire Fighting MeasuresClear fire area of all non-emergency Hazards:Hazardous combustion products may include: A complexmixture of airborne solid and liquid particulates and gases(smoke).

4 Carbon monoxide. Unidentified organic and ExtinguishingMedia:Foam, water spray or fog. Dry chemical powder, carbondioxide, sand or earth may be used for small fires Extinguis-hing Media:Do not use water in a Equipment for Firefighters:Proper protective equipment including breathing apparatusmust be worn when approaching a fire in a confined Accidental Release MeasuresAvoid contact with spilled or released material. For guidance on selection of personal protective equipment see Chapter 8 of this Material Safety data Sheet . See Chapter 13 for information on dis-posal.

5 Observe all relevant local and international Measures:Avoid contact with skin and eyes. Use appropriate containmentto avoid environmental contamination. Prevent from spreadingor entering drains, ditches or rivers by using sand, earth, orother appropriate Up Methods:Slippery when spilt. Avoid accidents, clean up from spreading by making a barrier with sand, earth orother containment material. Reclaim liquid directly or in anabsorbent. Soak up residue with an absorbent such as clay,sand or other suitable material and dispose of Advice:Local authorities should be advised if significant spillagescannot be data Sheet : date: 09-10-303/77 Handling and StorageGeneral Precautions:Use local exhaust ventilation if there is risk of inhalation ofvapours, mists or aerosols.

6 Properly dispose of anycontaminated rags or cleaning materials in order to preventfires. Use the information in this data Sheet as input to a riskassessment of local circumstances to help determineappropriate controls for safe handling, storage and disposal ofthis :Avoid prolonged or repeated contact with skin. Avoid inhalingvapour and/or mists. When handling product in drums, safetyfootwear should be worn and proper handling equipmentshould be :Keep container tightly closed and in a cool, well-ventilatedplace. Use properly labelled and closeable containers.

7 StorageTemperature: 0 - 50 C / 32 - 122 Materials:For containers or container linings, use mild steel or highdensity Information:Polyethylene containers should not be exposed to hightemperatures because of possible risk of class: 10 Fire hazard classification: Exposure Controls/Personal ProtectionOccupational Exposure LimitsExposure Controls:The level of protection and types of controls necessary will varydepending upon potential exposure conditions. Select controlsbased on a risk assessment of local measures include: Adequate ventilation to controlairborne concentrations.

8 Where material is heated, sprayed ormist formed, there is greater potential for airborneconcentrations to be Protective Equipment:Personal protective equipment (PPE) should meetrecommended national standards. Check with PPE Protection:No respiratory protection is ordinarily required under normalconditions of use. In accordance with good industrial hygienepractices, precautions should be taken to avoid breathing ofmaterial. If engineering controls do not maintain airborneconcentrations to a level which is adequate to protect workerhealth, select respiratory protection equipment suitable for thespecific conditions of use and meeting relevant with respiratory protective equipment suppliers.

9 Whereair-filtering respirators are suitable, select an appropriatecombination of mask and filter. Select a filter suitable forcombined particulate/organic gases and vapours [boiling point>65 C (149 F)] meeting Protection:Where hand contact with the product may occur the use ofgloves approved to relevant standards ( Europe: EN374,US: F739) made from the following materials may providesuitable chemical protection: PVC, neoprene or nitrile rubberSafety data Sheet : P34 date: 09-10-30 gloves. Suitability and durability of a glove is dependent onusage, frequency and duration of contact, chemicalresistance of glove material, glove thickness, dexterity.

10 Alwaysseek advice from glove suppliers. Contaminated gloves shouldbe replaced. Personal hygiene is a key element of effectivehand care. Gloves must only be worn on clean hands. Afterusing gloves, hands should be washed and dried of a non-perfumed moisturizer is Protection:Wear Safety glasses or full face shield if splashes are likely tooccur. Approved to EU Standard Clothing:Skin protection not ordinarily required beyond standard issuework Methods:Monitoring of the concentration of substances in the breathingzone of workers or in the general workplace may be required to confirm compliance with an OEL and adequacy of exposurecontrols.