Submittal Data and Specifications - Plastec Vent

Back Draft Dampers, Vertical GravityMaterial of Construction and Temperature Limitation: Body, damper plate and shaft shall be made of PVC. Back Draft Damper recommended up to 140 F. Application: Designed to operate in ducting where highly corrosive air is present. Designed to fit round schedule 40 PVC ducting or other construction materials as specified by the dimensions listed for each model damper. Manufacturer: Shall be manufactured under the authority of Plastec Ventilation, have the following Features and Benefits: All internal parts are plastic Can be installed vertically only Shall have bell end sockets and shall have minimum socket depth of 2 inches or more except on the 4 inch model which will be inches Allows for less than 5% airflow restriction Offers an approximate 95% sealWarranty:This equipment is warranted tobe free from defects in materialand workmanship

Back Draft Dampers, Vertical Gravity Material of Construction and Temperature Limitation: Body, damper plate and shaft shall be made of PVC. Back Draft Damper recommended up to 140° F.

Tags:

  Submittal

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Submittal Data and Specifications - Plastec Vent

1 Back Draft Dampers, Vertical GravityMaterial of Construction and Temperature Limitation: Body, damper plate and shaft shall be made of PVC. Back Draft Damper recommended up to 140 F. Application: Designed to operate in ducting where highly corrosive air is present. Designed to fit round schedule 40 PVC ducting or other construction materials as specified by the dimensions listed for each model damper. Manufacturer: Shall be manufactured under the authority of Plastec Ventilation, have the following Features and Benefits: All internal parts are plastic Can be installed vertically only Shall have bell end sockets and shall have minimum socket depth of 2 inches or more except on the 4 inch model which will be inches Allows for less than 5% airflow restriction Offers an approximate 95% sealWarranty.

2 This equipment is warranted tobe free from defects in materialand workmanship for two yearsfrom date of original the complete warrantyagreement, see I, O & M on Submittal Data and Specifications PROJECT ARCHITECT CONTRACTOR DATE SUBMITTED BY ENGINEERSPECIFICATION RELATED FAN POSITION MODEL # QTY NOTESPLASTEC VENTILATION, Phone: 941-751-7596 Fax: 941-751-7598 BCA30 . Dia. PVC Shaft - 10 & " Dia. PVC Shaft - 4" to 8".188" Blades - 10" & " Blades - 4" to 8".75" Thick Bearing BlockPVC DuctBD10BD12BD14BD08BD04BD06 DIMENSIONAL DATA (inches)4" " " " " " : Dampers are designed to be self-closing when installed in a vertical of 1