pipe HangersPipe Hangers offered in this section are designed to support insulated or non-insulated pipe allowing for verticaladjustment and limited movement in the piping Steel, Malleable Iron and AISI Type 304 & 316 Stainless Steel are used in the manufacturing of pipehangers. Other materials are standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black,Electro-Galvanized Zinc (ASTM B633 SC3), Pre-Galvanized (ASTM A653 G90), Hot-Dip Galvanized After Fabrication(ASTM A123), Red Primer, Plastic Coating, DURA-GREEN , DURA-COPPER and other special coatings areavailable upon : Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may notbe uniformly coated with special finishes Hot-Dip Galvanized, DURA-GREEN, DURA-COPPER, PVC etc. In somecases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, DURA-COPPERP ainted or Stainless Steel.

Pipe Hangers Pipe Hangers & Supports 48. Pipe Hangers B3100 - Standard Clevis Hanger (TOLCO Fig.1) B D C E A (Rod Size) Hanger Rod Not Included B Bottom of pipe to top of hanger. C Center of pipe to top of hanger. D Rod Take-Out Center of pipe to bottom of …

Tags:

  Support, Pipe, Hanger, Pipe hangers, Pipe hangers pipe hangers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Pipe Hangers - Southern Pipe & Supply

1 pipe HangersPipe Hangers offered in this section are designed to support insulated or non-insulated pipe allowing for verticaladjustment and limited movement in the piping Steel, Malleable Iron and AISI Type 304 & 316 Stainless Steel are used in the manufacturing of pipehangers. Other materials are standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black,Electro-Galvanized Zinc (ASTM B633 SC3), Pre-Galvanized (ASTM A653 G90), Hot-Dip Galvanized After Fabrication(ASTM A123), Red Primer, Plastic Coating, DURA-GREEN , DURA-COPPER and other special coatings areavailable upon : Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may notbe uniformly coated with special finishes Hot-Dip Galvanized, DURA-GREEN, DURA-COPPER, PVC etc. In somecases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, DURA-COPPERP ainted or Stainless Steel.

2 Consult B-Line Systems for (as noted)Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with FederalSpecification WW-H-171E & A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69 & Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD)All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise HangersPipe Hangers & Supports47 pipe HangersSize Range:Size 1" (25mm)thru 20" (500mm)clevis hangerMaterial:SteelFunction:Used as a spacer at a seismic brace location tokeep clevis hanger from collapsing during seismic :Included in our Seismic Restraints Catalogapproved by the State of California Office of StatewideHealth Planning and Development (OSHPD). For additionalload, spacing and placement information relating to OSHPD projects, please refer to the Seismic Restraint Note:Fig.

3 1 CBS fits easily over the cross boltand attaches by pinching tabs :Pre-Galvanized. Contact B-Line for alternativefinishes and By:Partnumber and 1 CBS - Clevis pipe Spacer (Cooper B-Line B3100PS) pipe SizeApprox. (mm)lbs.(kg)1 CBS-11 (25) ( )1 CBS-11/411/4 (32) ( )1 CBS-11/211/2 (40) ( )1 CBS-22 (50) ( )1 CBS-21/221/2 (65) ( )1 CBS-33 (75) ( )1 CBS-31/231/2 (90) ( )1 CBS-44 (100) ( )1 CBS-55 (125) ( )1 CBS-66 (150) ( )1 CBS-88 (200) ( )1 CBS-1010 (250) ( )1 CBS-1212 (300) ( )1 CBS-1414 (350) ( )1 CBS-1616 (400) ( )1 CBS-1818 (450) ( )1 CBS-2020 (500) ( )Component of State ofCalifornia OSHPD ApprovedSeismic Restraints SystemAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise Hangers48 pipe Hangers & SupportsPipe HangersB3100 - Standard Clevis hanger (TOLCO )BDCEA(Rod Size) hanger Rod NotIncludedBBottom of pipe to top of of pipe to top of Take-OutCenter of pipe to bottom ofhanger thread length ofhanger rodFAdjustmentTop of cross bolt to bottom of hangerrod nut inside the pipe SizeRod Size ABCDPart (mm)StdNFPA**in.

4 (mm)in. (mm)in.(mm)B3100-1/21/2"(15)3/8"-163/8"- 1621/8"( )13/4"( )15/16"( )B3100-3/43/4"(20)3/8"-163/8"-1621/2"( )2"( )11/8"( )B3100-11"(25)3/8"-163/8"-1627/8"( )21/4"( )13/8"( )B3100-11/411/4"(32)3/8"-163/8"-1631/2"( )211/16"( )113/16"( )B3100-11/211/2"(40)3/8"-163/8"-164"( )`31/16"( )21/4"( )B3100-2 *2"(50)3/8"-163/8"-1641/2"( )35/16"( )21/2"( )B3100-21/2*21/2"(65)1/2"-133/8"-1653/8" ( )315/16"( )31/16"( )B3100-3 *3"(80)1/2"-133/8"-1661/2"( )43/4"( )315/16"( )B3100-31/231/2"(90)1/2"-133/8"-1671/4"( )51/4"( )41/16"( )B3100-4 *4"(100)5/8"-113/8"-1673/4"( )51/2"( )51/2"( )B3100-5 *5"(125)5/8"-111/2"-1383/4"( )61/8"( )6"( )B3100-6 *6"(150)3/4"-101/2"-13105/16"( )615/16"( )7"( )B3100-88"(200)3/4"-101/2"-13123/4"( )87/16"( )71/8"( )B3100-1010"(250)7/8"-95/8"-11151/8"( )93/4"( )83/8"( )B3100-1212"(300)7/8"-95/8"-11171/2"( )111/8"( )911/16"( )B3100-1414"(350)1"-8--193/8"( )123/8"( )105/8"( )B3100-1616"(400)1"-8--213/8"( )133/8"( )119/16"( )B3100-1818"(450)

5 1"-8--25"( )16"( )143/16"( )B3100-2020"(500)11/4"-7--283/4"( )173/4"( )165/8"( )B3100-2424"(600)11/4"-7--323/4"( )193/4"( )185/8"( )B3100-3030"(750)11/4"-7--3915/16"( )2415/16"( )223/4"( )B3100-3636"(900)11/4"-7--46"( )28"( )25"( )*SLIDE-RITE Clevis Hangerdesign, as shown below, forsizes 2, 21/2, 3, 4, 5 & No. 5,848,7705,924,655 SLIDE-RITE Clevis hanger FeaturesPipe will not pinch when swing in either direction allows pipe to easilyfeed design aligns bolt holes for quickeroverhead of State ofCalifornia OSHPD ApprovedSeismic Restraints SystemAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise HangersPipe Hangers & Supports49 pipe HangersEAdjustment FDesign LoadApprox. (mm)in.(mm)Lbs.(kN)Lbs.(kg)B3100-1/221/2 "( )7/16"( )730( )25( )B3100-3/421/2"( )1/2"( )730( )29( )B3100-121/2"( )5/8"( )730( )35( )B3100-11/421/2"( )7/8"( )730( )40( )B3100-11/221/2"( )13/16"( )730( )42( )B3100-2 *21/2"( )15/8"( )730( )52( )B3100-21/2*21/2"( )2"( )1350( )90( )B3100-3 *21/2"( )2"( )1350( )110( )B3100-31/221/2"( )2"( )1350( )142( )B3100-4 *21/2"( )2"( )1430( )132( )B3100-5 *21/2"( )2"( )1430( )215( )B3100-6 *3"( )2"( )1940( )320( )B3100-831/2"( )25/16"( )2000( )485( )B3100-1031/2"( )25/16"( )3600( )846( )B3100-1231/2"( )25/8"( )3800( )1083( )B3100-144"( )27/8"( )4200( )1432( )B3100-164"( )211/16"( )4600( )2200( )B3100-1841/2"( )315/16"( )4800( )2500( )B3100-205"( )53/8"( )4800( )4400( )B3100-245"( )53/8"( )4800( )5000( )B3100-305"( )61/4"( )6000( )6600( )B3100-365"( "( )6000( )8474( )Size Range:1/2 (15mm)to 36 (900mm)Material:SteelFunction:Recommende d for the suspension of non-insulated pipe or insulated pipe with a B3151.)

6 When an oversized clevis is used, a pipe spacer should be placed over the cross bolt to assure that thelower U-strap will not move in on the bolt. When attaching seismic bracing to the clevis Hangers , a B3100PS(cross bolt spacer) must be installed. See Seismic Restraints Approval pipe sleeves Fig. 1 CBS-( pipe size) :Included in our Seismic Restraints Catalog approved by the State of California Office of StatewideHealth Planning and Development (OSHPD). For additional load, spacing and placement information relating toOSHPD projects, please refer to the B-Line/TOLCO Seismic Restraint Systems Guidelines. Underwriter'sLaboratories Listed in the USA (UL)and Canada (cUL)for sizes 3/4 (20mm)thru 12" (300mm). Factory MutualEngineering Approved (FM)for 3/4 (20mm)thru 12 (300mm) pipe . Conforms to Federal Specification WW-H-171E &A-A-1192A, Type 1 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type available toaccommodate rod schedule per per National Fire Protection Association (NFPA) Pamphlet Temperature:650 F (343 C).

7 Standard Finish: Plain, Electro-Galvanized, DURA-GREEN , or Hot-Dip Galvanizedalso available in Stainless SteelOrder By:Partnumber and AWWA - Ductile Iron Clevis Hangers , see B3102, page 51.** Note:Do not use the dimensions shown in the B3100 chart for NFPA hanger B-Line for NFPA rod sizing on 1/2 (15mm)thru 12 (300mm) numbers will be 1 NFPA- pipe - Standard Clevis hanger (TOLCO )*SLIDE-RITE Clevis hanger design, as shown above, for sizes 2, 21/2, 3, 4, 5 & of State ofCalifornia OSHPD ApprovedSeismic Restraints SystemAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise Hangers50 pipe Hangers & SupportsSize Range:4 (100mm)to 24 (600mm)Material:SteelFunction:Recommende d for the suspension offlanged or bell and spigot cast iron orductile iron pipe . The of the ironpipe is shown in the data :Conforms to Federal SpecificationWW-H-171E & A-A-1192A, Type 1 andManufacturers Standardization Society ANSI/MSSSP-69 & SP-58, Type Finish: Plain & B-Line for alternative finishes By:Part number and - Clevis hanger (TOLCO ) pipe Rod SizeBCDEFD esign LoadApprox.

8 (mm)Ain.(mm) in.(mm) in.(mm) in. (mm) in.(mm) Lbs. (kN) Lbs.(kg) ( )5/8"-11 85/16"( )513/16"( ) 45/8"( )21/2"( )2"( )1430( )203( ) ( )3/4"-10 105/8"( )71/16"( ) 513/16"( )3"( )2"( )1940( )352( ) ( )3/4"-10 131/4"( )85/8"( ) 73/16"( )31/2"( )21/8"( )2000( )532( ) ( )7/8"-9 157/8"( )101/4"( ) 811/16"( )31/2"( )21/4"( )3600( )800( ) ( )7/8"-918"( )115/16"( ) 93/4"( )31/2"( )21/4"( )3800( )1152( ) ( )1"-8 203/8"( )125/8"( ) 113/16"( )4"( )27/8"( )4200( )1449( ) ( )1"-8 231/2"( )1411/16"( ) 127/8"( )4"( )33/8"( )4600( )2100( ) ( )1"-8 255/8"( )153/4"( ) 1315/16"( )41/2"( )33/8"( )4800( )2294( ) ( )11/4"-7 291/2"( )189/16"( ) 177/16"( )5"( )413/16"( )4800( )3887( ) ( )11/4"-7 33"( )191/8"( ) 20"( )5"( )51/4"( )4800( )4844( )BDCEA(Rod Size) hanger Rod NotIncludedBBottom of pipe t0 top of of pipe to top of Take-OutCenter of pipe to bottom ofhanger thread length ofhanger rodFAdjustmentTop of cross bolt to bottom of hangerrod nut inside the HangersAll dimensions in charts and on drawings are in inches.

9 Dimensions shown in parentheses are in millimeters unless otherwise HangersPipe Hangers & Supports51 Nominal pipe Size Rod SizeBCDPart (mm)Ain. (mm)in. (mm)in.(mm)B3108-3/43/4"(20)3/8"-1643/8" ( )313/16"( )31/16"( )B3108-11"(25)3/8"-1643/4"( )41/16"( )31/4"( )B3108-11/411/4"(32)3/8"-1653/8"( )41/2"( )35/16"( )B3108-11/211/2"(40)3/8"-1667/8"( )515/16"( )51/8"( )B3108-22"(50)3/8"-16813/16"( )75/8"( )67/8"( )B3108-21/221/2"(65)1/2"-1310"( )81/2"( )79/16"( )B3108-33"(80)1/2"-13105/8"( )813/16"( )77/8"( )B3108-44"(100)5/8"-11 1113/16"( )91/2"( )83/8"( )B3108-55"(125)5/8"-11131/8"( )105/16"( )91/8"( )B3108-66"(150)3/4"-10143/8"( )11"( )911/16"( )B3108-88"(200)3/4"-10163/4"( )123/8"( )111/8"( )B3108-1010"(250)7/8"-9191/4"( )1313/16"( )125/16"( )B3108-1212"(300)7/8"-9215/8"( )153/16"( )135/8"( )EFHD esign LoadApprox. (mm)in.(mm) in.(mm) lbs.(kN)lbs.(kg)B3108-3/421/2"( )1/2"( )2"( )730( )45( )B3108-121/2"( )5/8"( )2"( )730( )49( )B3108-11/421/2"( )7/8"( )2"( )730( )55( )B3108-11/221/2"( )13/16"( )2"( )730( )67( )B3108-221/2"( )15/8"( )4"( )730( )83( )B3108-21/221/2"( )2"( )4"( )1350( )177( )B3108-321/2"( )2"( )4"( )1350( )191( )B3108-421/2"( )2"( )4"( )1430( )237( )B3108-521/2"( )2"( )4"( )1430( )302( )B3108-63"( )2"( )4"( )1940( )397( )B3108-831/2"( )25/16"( )4"( )2000( )582( )B3108-1031/2"( )25/16"( )4"( )3600( )968( )B3108-1231/2"( )25/8"( )4"( )3800( )1221( )B3108 - Extended Clevis hanger (TOLCO )Size Range:3/4 (20mm)thru 12 (300mm) pipeMaterial:SteelFunction:Recommended for the suspension of insulatedpipe where the temperature does not require the use ofslides, guides, or rollers for :Conforms to Federal Specification WW-H-171E& A-A-1192A, Type 1 and Manufacturers StandardizationSociety ANSI/MSS SP-69 & SP-58, Type Temperature: 650 F (343 C).

10 Order By:Part number and finish. For service For Stainless Steel add SS to part Finish: Plain, Electro-Galvanized or Hot DipGalvanizedFor service temperatures of 750 F (399 C) thru1050 F (565 C) specify Type 304 Stainless SteelBDCEA(Rod Size) hanger Rod NotIncludedBBottom of pipe to top of of pipe to top of Take-OutCenter of pipe to bottom ofhanger thread length ofhanger of cross bolt to bottom ofhanger rod nut inside the insulation HangersAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise Hangers52 pipe Hangers & SupportsEAdjustment FDesign LoadApprox. (mm)in.(mm)Lbs.(kN)Lbs.(kg)B3100-1/221/2 "( )7/16"( )730( )25( )B3100-3/421/2"( )1/2"( )730( )29( )B3100-121/2"( )5/8"( )730( )35( )B3100-11/421/2"( )7/8"( )730( )40( )B3100-11/221/2"( )13/16"( )730( )42( )B3100-221/2"( )15/8"( )730( )52( )B3100-21/221/2"( )2"( )1350( )90( )B3100-321/2"( )2"( )1350( )110( )B3100-31/221/2"( )2"( )1350( )142( )B3100-421/2"( )2"( )1430( )132( )B3100-521/2"( )2"( )1430( )215( )B3100-63"( )2"( )1940( )320( )B3100-831/2"( )25/16"( )2000( )485( )Size Range:1/2 (15mm)to 8 (200mm)pipeMaterial:SteelInsulation Material:3/16 ( )FeltService:The B3100F is designed for the suspension ofcopper tube so as to prevent electrolysis between tubingand hanger .