PanelMate ControlNet Communication Driver Manual

Eaton CorporationCutler-Hammer Group811 Greencrest DriveColumbus, OH 43081 PanelMate ControlNetCommunication DriverManualThe information contained in this Manual is the property of Eaton Corporation. Information in thismanual is subject to change without notice and does not represent a commitment on the part of EatonCorporation. Permission is granted to duplicate this material without modification only for your use orthe internal use of other members of your company or your agents to assist you in the use andservicing of products purchased from Eaton s Cutler-Hammer Group. No permission is granted tomodify this material or include this material in a Cutler-Hammer software described in this Manual is furnished under a license agreement. Thesoftware may be used or copied only in accordance with the terms of the agreement. It is against the lawto copy the software on any medium except as specifically allowed in the RIGHTS LEGENDUse, duplication, or disclosure by the Government is subject to restrictions set forth in paragraph(b)(3)(B) of the Rights in Technical Data and Computer Software clause of DAR (a).

2-2 PanelMate ControlNet Communication Driver Manual Hardware Layout Below is a graphic representation of the end view of the ControlNet interface card. J3 J2 SW1 4 2 3 1 The top set of stacked LED's are used to monitor UCS and network specific status.

Tags:

  Manual, Nameplates, Communication, Drivers, Interface, Controlnet, Controlnet interface, Panelmate controlnet communication driver manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of PanelMate ControlNet Communication Driver Manual

1 Eaton CorporationCutler-Hammer Group811 Greencrest DriveColumbus, OH 43081 PanelMate ControlNetCommunication DriverManualThe information contained in this Manual is the property of Eaton Corporation. Information in thismanual is subject to change without notice and does not represent a commitment on the part of EatonCorporation. Permission is granted to duplicate this material without modification only for your use orthe internal use of other members of your company or your agents to assist you in the use andservicing of products purchased from Eaton s Cutler-Hammer Group. No permission is granted tomodify this material or include this material in a Cutler-Hammer software described in this Manual is furnished under a license agreement. Thesoftware may be used or copied only in accordance with the terms of the agreement. It is against the lawto copy the software on any medium except as specifically allowed in the RIGHTS LEGENDUse, duplication, or disclosure by the Government is subject to restrictions set forth in paragraph(b)(3)(B) of the Rights in Technical Data and Computer Software clause of DAR (a).

2 Contractor/Manufacturer is Eaton Corporation s Cutler-Hammer Group, 811 Greencrest Drive,Columbus, OH is a registered trademark of Eaton s Cutler-Hammer , Microsoft, and Windows are registered trademarks of Microsoft names of products from other manufacturers or developers that appear in this Manual areregistered or unregistered trademarks of those respective manufacturers or developers, which haveexpressed neither approval nor disapproval of Eaton s Cutler-Hammer Group Eaton Corporation, 2001. All rights in the United States of 01-00484-00 Table of ContentsiTable of this s 1: 2: ControlNet interface interface 3: Operator Station to One Stations to Multiple Station Connection to ControlNet using the ControlNet interface 4: Memory Addressing and Communications to Allen-Bradley PLC-5 Using DF1 (PCCC) Memory Addressing 5: Memory Addressing and Communications to the Allen-Bradley ControlLogix UsingControl Information Protocol (CIP) Addressing Using PLC-5 or SLC Address Tags versus Program Memory A: Error ControlNet Communication Driver ManualControlNet interface Peer Error to Cutler-Hammer s PanelMate ControlNet Communication Driver Manual .

3 This chaptergives a brief overview of this Manual , and provides information on Support ControlNet Communication Driver ManualAbout this ManualPurposeThis Manual describes how to use your Operator Station with s InsideThis Manual is organized in the following way:PrefaceChapter 1:Introduction, describes the ControlNet Driver 2: ControlNet interface Module, describes the hardware layout of the ControlNetModule, as well as a description of the LED indicators and their 3:Connectivity, describes supported messaging, how the ControlNet moduleconnects to the network, the connectivity options, how to configure the PLC Nameand Port Table in PanelMate software, and wiring 4:Memory Addressing and Communications to the Allen-Bradley PLC-5 Using DF1(PCCC) Messaging, describes PCCC references, memory addressing for the PLC-5,and monitored 5 Memory Addressing and Communications to the Allen-Bradley ControlLogixUsing Control Information Protocol (CIP) Messaging, describes CIP referencesand memory addressing for ControlLogix A:Error Codes, describes ControlNet Peer Error listing of important names, subjects, and titles found within thismanual, with their page ServicesIt is Cutler-Hammer s goal to ensure your greatest possible satisfaction with the operation of ourproducts.

4 We are dedicated to providing fast, friendly, and accurate assistance. That is why we offeryou so many ways to get the support you need. Whether it s by phone, fax, modem, or mail, you canaccess Cutler-Hammer support information 24 hours a day, seven days a week. Our wide range ofservices include:Technical SupportVOICE 1-800-809-2772 FAX 614-882-0417 EMAIL you are in the or Canada, you can take advantage of our toll-free line for technical assistancewith hardware and software product selection, system design and installation, and system debuggingand diagnostics. Technical support engineers are available for calls during regular business hours(8 am - 5:30 pm EST) by calling 1-800-809-2772. International calls can be made to either the Tech Line at1-800-809-2772 (toll call) or the Cutler-Hammer main business line at 614-882-3282. You can contact ourtechnical support engineers by faxing your support requests directly to the Advanced Product SupportCenter (APSC) located in Columbus, Ohio at 614-882-0417.

5 You can also contact our technical supportengineers by emailing your support requests to Technical SupportVOICE 1-800-809-2772 Because machines do not run on a nine-to-five schedule, we offer emergency after-hours technicalsupport. A technical support engineer can be paged for emergencies involving plant down situations orsafety issues. Emergency support calls are automatically routed directly to our answering serviceafter-hours (5:30 pm - 8 am EST) and weekends. For emergency technical support, call that the Emergency Technical Support phone number does not currently support product repairsor shipping outside normal business Fax-Back ServiceFAX 614-899-5323 The latest Cutler-Hammer product information, specifications, technical notes and company news isavailable to you via fax through our direct document request service at 614-899-5323. Using a touch-tone phone, you can select any of the info faxes from our automated product literature and technicaldocument library, punch in a fax number and receive the information you have Internet capabilities, you also have access to technical support via our website The website includes technical notes, frequentlyasked questions, release notes, and other technical documentation.

6 This direct technical supportconnection also offers you the ability to request assistance and exchange software files Board ServiceMODEM 614-899-5209 Parameters: 8 data bits, 1 stop bit, parity none, baudIf you have modem access, you can dial in directly to our electronic bulletin board service for the latestproduct and company information. File sharing, product software downloads and our user messageservice are just a few of the things you will find online at ControlNet Communication Driver ManualSoftware RegistrationFAX 614-899-4141 EMAIL your software and receive free information updates regarding Cutler-Hammer will include details of software modificatioins, product enhancements, and reduced-pricesoftware upgrades. Registering your software also gives you access to Technical Support. You canregister your software by using the registration form included with the software you have Internet capabilities, you can register your software via our website Select Tech Support then Automation UpdateService.

7 Go to the Software Registration Form, fill it in and then submit the and Upgrade ServiceVOICE 614-882-3282 ext. 7601 FAX 614-882-3414 Our well-equipped Customer Service department is ready to assist you with repairs, upgrades, andspare parts services. If a situation arises where one of these services is needed, just call 614-882-3282x7601 or fax Support CenterVOICE 1-800-356-1243 FAX 1-800-752-8602 Authorized Cutler-Hammer distributors and Cutler-Hammer sales offices can get assistance forCutler-Hammer standard and component product lines through the Customer Support Center. Callthe Customer Support Center for the following assistance:1. To place an Stock availability, proof of Expedite an existing Product assistance and product price Product returns other than warranty Information on local distributors or sales CorporationCutler-Hammer Group811 Greencrest DriveColumbus, OH 43081 Chapter 1: Introduction1-1 IntroductionThis chapter discusses: Driver installation11-2 PanelMate ControlNet Communication Driver ManualDriver InstallationThe Driver Software Kit contains a : Before installing the drivers , make sure that the PanelMate Configuration software is notalready install the drivers from the CD-ROM, select the Install Software option and then Install the dialog box, select the ControlNet Driver you wish to install and then press the OK 2: ControlNet interface Module2-1 ControlNet interface ModuleThis chapter discusses.

8 The Hardware Layout Address Settings LED Indicators22-2 PanelMate ControlNet Communication Driver ManualHardware LayoutBelow is a graphic representation of the end view of the ControlNet interface card. J3 J2 SW1 4 2 3 1 The top set of stacked LED's are used to monitor UCS and network specific status. The bottom set ofstacked LED's are used to monitor redundant ControlNet channel status. See the table below for a moredetailed description of each interface Status2 Network Specific Status3 Channel B Status4 Channel A StatusJ2 ControlNet Channel A BNC ConnectorJ3 ControlNet Channel B BNC ConnectorSW1 ControlNet Addressing SwitchesSee following table for address 2: ControlNet interface Module2-3 Address SettingsAddressAddress123456781234567800 0000000500011001010000000151001100112000 0001052001101003000000115300110101400000 1005400110110500000101550011011160000011 0560011100070000011157001110018000010005 8001110109000010015900111011100000101060 0011110011000010116100111101120000110062 0011111013000011016300111111140000111064 0100000015000011116501000001160001000066 0100001017000100016701000011180001001068 0100010019000100116901000101200001010070 0100011021000101017101000111220001011072 0100100023000101117301001001240001100074 0100101025000110017501001011260001101076 0100110027000110117701001101280001110078 0100111029000111017901001111300001111080 0101000031000111118101010001320010000082 0101001033001000018301010011340010001084 0101010035001000118501010101360010010086 0101011037001001018701010111380010011088 0101100039001001118901011001400010100090 0101101041001010019101011011420010101092 0101110043001010119301011101440010110094 0101111045001011019501011111460010111096 0110000047001011119701100001480011000098 0110001049001100019901100011 Switch PositionSwitch Position2-4 PanelMate ControlNet Communication Driver ManualLED IndicatorsNet Status (Item 2)The Network Specific LED is the upper-right LED on the ControlNet interface card.

9 See page 2 for a sideview of the card. The following table describes the behavior of the Network Specific LED:LED StateNetwork StatusOffNetwork interface offline/No network powerFlashing RedI/O Connection(s) in timed-out state or other Recoverable GreenDevice is online, but has no running connectionsSolid RedUnrecoverable FaultSolid GreenOnline with established connectionsFlashing Green/RedSelf-test for A-B devicesControlNet interface Status (Item 1)The ControlNet interface status LED is the lower-right LED on the ControlNet interface card. See page 2for a side view of the card. The following table describes the behavior of the UCS status StateStatusOffNo powerSolid RedHardware errorFlashing RedRecoverable configuration fault(Invalid firmware, OEM data, or Personality Block)Flashing GreenNo errorsSolid GreenNo errorsAmberConfiguration modeChannel StatusThe Channel Status LEDs are the left-most stacked set of LEDs on the on the ControlNet interface page 2 for a side view of the card.

10 They are read together when their states change synchronouslyto one StatusOffNetwork interface RedNetwork faulted state or other recoverable faultAlternating Red/GreenNetwork ASIC self testAlternating Red/OffIncorrect node ControlNet parameters or node Channel Status LEDs are read independently when their states change asynchronous to oneanother:StatesNetwork StatusOffNetwork channel disabled. Redundant Cable operation GreenOnline normal Red/OffMedia fault or no other nodes for broken cables, bad connectors, Green/OffDevice is online, but is encountering temporary errors. Checktermination and Green/RedIncorrect network 2: ControlNet interface Module2-5 ConnectorsThe Channel A and Channel B connectors (J2 and J3 respectively,) on the ControlNet interface card,provide redundant coax media connections to ControlNet using standard BNC female connectors.