Transcription of Fluke current clamps - Fluke Corporation
1 Fluke current clampsFor use with DMMs, ScopeMeters and Power Quality AnalyzersAccessoriesAC/DC current clamp specifications80i-110si410i1010i30i30sDc a to 100 a1 to 400 a1 to 1000 a30 ma to 30 a30 ma to 30 aac a to 70 a1 a to 400 a1 a to 600 a30 ma to 20 a rms30 ma to 20 a a to 10 a ; dc to 1 khz: 3 % + 50 ma; up to 100 a add 15 %; up to 20 khz add 12 % % + a for dc or ac (45 to 400 h z)2 % + a for dc or ac (45 to 400 h z) 1 % of reading, 2 ma 1 % of reading, 2 maBandwidth (-3 dB)100 khZ3 khz10 khzdc to 20 khz ( dB) dc to 100 khz ( dB)Zero error adjustmentYesYesYesYesYesMaximum conductor mm ( in)30 mm ( in)30 mm ( in)19 mm ( in)19 mm ( in)
2 Maximum conductor size1 aWG750 McM or 2-500 McM750 McM or 2-500 McM250 McM250 McMOutput levels10 mV/a, 100 mV/a1 mV/a1 mV/a100 mV/a100 mV/aOutput meter with BNc meter with shroud-ed banana meter with shroud-ed banana meter with shroud-ed dual banana plue2 meter with BNc terminationBattery life40 hours60 hours60 hours30 hours30 hoursWarrantyOne-yearOne-yearOne-yearOne -yearOne-yearsafetycat II 600 V; cat III 300 Vcat III 600 Vcat III 600 Vcat III 300 Vcat III 300 VAC/DC modelsi410i101080i-110si5sPQ3i30si30i30s and i30 Hall Effect AC/DC current clamps Especially useful for low current measure-ments down to 30 milliampsPower quality ac combo packs for 4-phase current measurements67i430flex 4-packAC/DC clamp -on current probe compatibilityMeter 80i-110si410i1010i30i30s10/11/12/12B/16 a to 100 a dc and a to 70 a ac*5 a to 400 a dc and 7 a to 400 a ac5 a to 1000 a dc and 7 a to 600 a ac40 ma
3 To 30 a dc and 60 ma to 20 a ac40 ma to 30 a dc and 60 ma to 20 a ac110/111 a to 100 a dc and 3 a to 70 a ac*5 a to 400 a dc and 300 a to 400 a ac5 a to 1000 a dc and 300 a to 600 a ac40 ma to 30 a dc and 3 a to 20 a ac40 ma to 30 a dc and 3 a to 20 a ac114/115/116 a to 100 a dc and a to 70 a ac* a to 400 a dc and 6 a to 400 a a to 1000 a dc and 6 a to 600 a ac30 ma to 30 a dc and 60 ma to 20 a ac30 ma to 30 a dc and 60 ma to 20 a ac21/23/70/73/75/77 series a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 5 a to 400 a ac1 a to 1000 a dc and 5 a to 600 a ac30 ma to 30 a dc and 40 ma to 20 a ac30 ma to 30 a dc and 40 ma to 20 a ac26/79 s eries a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 20 a to 400 a ac1 a to 1000 a dc and 20 a to 600 a ac30 ma to 30 a dc and 200 ma to 20 a ac30 ma to 30 a dc and 200 ma to 20 a a to 100
4 A dc and a to 70 a ac*1 a to 400 a dc and 1 a to 400 a ac1 a to 1000 a dc and 1 a to 600 a ac30 ma to 30 a dc and 30 ma to 20 a ac30 ma to 30 a dc and 30 ma to 20 a a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 5 a to 400 a ac1 a to 1000 a dc and 5 a to 600 a ac30 ma to 30 a dc and 40 ma to 20 a ac30 ma to 30 a dc and 40 ma to 20 a ac175/177 a to 100 a dc and a to 70 a ac* a to 400 a dc and 30 a to 400 a a to 1000 a dc and 30 a to 600 a ac30 ma to 30 a dc and 300 ma to 20 a ac30 ma to 30 a dc and 300 ma to 20 a ac1577/1587 Insulation a to 100 a dc and a to 70 a ac* a to 400 a dc and 30 a to 400 a a to 1000 a dc and 30 a to 600 a ac30 ma to 30 a dc and 300 ma to 20 a ac30 ma to 30 a dc and 300 ma to 20 a ac83-III/83- a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 1 a to 400 a ac1 a to 1000 a dc and 1 a to 600 a ac30 ma to 30
5 A dc and 30 ma to 20 a ac30 ma to 30 a dc and 30 ma to 20 a ac85-III/87- a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 20 a to 400 a ac1 a to 1000 a dc and 20 a to 600 a ac30 ma to 30 a dc and 200 ma to 20 a ac30 ma to 30 a dc and 200 ma to 20 a ac87-IV/89-IV/187 a to 100 a dc and a to 70 a ac*1 a to 400 a dc and a to 400 a ac1 a to 1000 a dc and a to 600 a ac30 ma to 30 a dc and 30 ma to 20 a ac30 ma to 30 a dc and 30 ma to 20 a ac8060a/8062a a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 20 a to 400 a ac1 a to 1000 a dc and 20 a to 600 a ac30 ma to 30 a dc and 200 ma to 20 a ac30 ma to 30 a dc and 200 ma to 20 a ac860 s eries Graphical a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 30 a to 400 a ac1 a to 1000 a dc and 30 a to 600 a ac30 ma to 30 a dc and 300 ma to 20 a ac30 ma to 30 a dc and 300 ma to
6 20 a ac39/41B p ower MeterUsable but will read 10 or 100 times higher1 a to 400 a ac** Not spec d for dc1 a to 600 a ac** Not spec d for dcUsable but will read 100 times higher**Usable but will read 100 times higher9X s copeMeter s a to 100 a dc and a to 70 a ac1 a to 400 a dc and 5 a to 400 a ac**1 a to 1000 a dc and 5 a to 600 a ac**30 ma to 30 a dc and 50 ma to 20 a ac**30 ma to 30 a dc and 50 ma to 20 a ac123/124 s a to 100 a dc and a to 70 a ac1 a to 400 a dc and 25 a to 400 a ac**1 a to 1000 a dc and 25 a to 600 a ac**30 ma to 30 a dc and 250 ma to 20 a ac**30 ma to 30 a dc and 250 ma to 20 a ac190 s eries s a to 100 a dc and a to 70 a ac1 a to 400 a dc and 5 a to 400 a ac**1 a to 1000 a dc and 5 a to 600 a ac**30 ma to 30 a dc and 50 ma to 20 a ac**30 ma to 30 a dc and 50 ma to 20 a ac45 a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 15 a to 400 a ac1
7 A to 1000 a dc and 15 a to 600 a ac30 ma to 30 a dc 150 ma to 20 a ac30 ma to 30 a dc 150 ma to 20 a ac8845 a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 1 a to 400 a ac1 a to 1000 a dc and 1 a to 600 a ac30 ma to 30 a dc and 30 ma to 20 a ac30 ma to 30 a dc and 30 ma to 20 a ac705 a to 100 a dc, No ac*4 a to 400 a dc, No ac4 a to 1000 a dc, No ac40 ma to 30 a dc, No ac40 ma to 30 a dc, no ac715/724/725 a to 100 a dc, No ac*4 a to 400 a dc, No ac4 a to 1000 a dc, No ac40 ma to 30 a dc, No ac40 ma to 30 a dc.
8 No ac74X s eries p rocess a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 110 a to 400 a ac1 a to 1000 a dc and 110 a to 600 a ac30 ma to 30 a dc and a to 20 a ac30 ma to 30 a dc and a to 20 a ac787/789 p rocess a to 100 a dc and a to 70 a ac*1 a to 400 a dc and 20 a to 400 a ac1 a to 1000 a dc and 20 a to 600 a ac30 ma to 30 a dc and 200 ma to 20 a ac3 ma to 30 a dc and 200 ma to 20 a ac* r equires p M9080/001 a dapter** r equires p M9082/001 a dapterFor more information and detailed specifications, go to