Transcription of T I M E R S QUICK REFERENCE GUIDE - rhomberg.com.au
1 TIMERS. QUICK REFERENCE GUIDE . MULTI-FUNCTION TIMERS. PRODUCT 48T100 48T101 AT100 ST100/ST101 AT110. Multi-Function Delayed ON / Multi-Function Multi-Function Electronic Reset Timer Interval (One Shot) Timer Timer Timer Timer ORDERING TYPE. SUPPLY. VOLTAGE TYPE. SUPPLY. VOLTAGE TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS. CODE 48T100 - 11 _ 230 48T101 - 08 _ 230 AT100 / 250 A D ST100 / 415 AC S AT110 / 230 A S. back A1 15 back A1 15 25. FRONT PLATE front A-LINE AT100. front Y 1. A-LINE. Y2. AT110. Y3. Electronic Reset Timer Multi-Function Timer SLIMLINE ST-100.
2 CONTROLS 1. 2. 3 S1 Multi-Function Function 1. 2. 3 S1. Function 4 4. Timer L2 L2 L1 L1. P1 P1 sec. L1 L1 sec. min. S2 Range min. S2. A SEC A SEC Range hrs. L = LED S1. FUNCTION. SEC. RANGE. S2 S1. FUNCTION RANGE. S2. L2 10. hrs. 40 60. L2. 5. 10. 20. 5 20. P = Potentiometer 0. 0. TEST. 1 10. S3 0. TEST. 1 10. S3 Scale 2 50 S3. 20. + 80. P1 Scale 2. 100. 50 S3. MODE MODE. S = Selector Switch Mode 48T100. 48T100. SCALE. Mode 48T101. SCALE. 40%. 100. 0% 100% L3 40%. 70%. 70% 10%. P1. 10%. P1 18s Function Time Set 100%. Supplied with Supplied with Time Set 100% Relay 75s 1. LED 1 15s 30s 2. 3. panel-mount bezel panel-mount bezel ON 60s 4.
3 S2 front 26 28 Y4. front 120s back 16 18 A2. back 16 18 A2. S1. 11-pin plug-in (48x48) 8-pin plug-in (48x48) DIN rail mount 11-pin plug-in DIN rail mount FEATURES Six programmable timing Delayed ON or Interval (one Programmable: Programmable: Programmable: functions shot) operation - Delayed ON -Delayed ON - Delayed ON. Time settings from to Time settings from to - Interval (one shot) -Interval (one shot) hold or pulse reset 100 hrs, in 8 overlapping time 100 hrs, in 8 overlapping - Symmetrical Recycling -Symmetrical Recycling - Interval (one shot). ranges time ranges OFF-ON OFF-ON hold or pulse reset Separate Start, Reset& Gate Programmable: - Symmetrical Recycling - Symmetrical Recycling Inputs 18 overlapping time ON-OFF ON-OFF.
4 Polarity Protection on inputs ranges to 100 hrs Programmable: Programmable: Extra Short Housing Extra Short Housing High repetitive accuracy High repetitive & setting High repetitive & setting 18 overlapping time 6 overlapping time ranges Time setting on calibrated accuracy accuracy ranges to 100 hrs ST-100: up to 120 sec scale (10% to 100%). Automatic pulse or hold start Power-up start High repetitive accuracy ST-101: up to 240 min Direct interface with DC. Power ON and Relay ON Power ON and Relay ON Time setting on calibrated PNP/NPN sensors LED's LED's scale (10% to 100%) High speed electronic reset Front dial can be used as Front dial can be used as Power ON and Relay ON 415V Power supplies Power ON and Relay ON.
5 Screwdriver for adjusting screwdriver for adjusting LED's available in ST100 & ST101. LED's settings settings Microprocessor technology Flashing Power ON LED. Microprocessor technology Microprocessor technology incorporated High repetitive accuracy when unit is timing based based Flashing Power ON LED DPDT (5A per contact) Microprocessor technology Flashing Power ON LED Flashing Power ON LED when unit is timing incorporated when unit is timing when unit is timing DPDT (5A per contact) 5A SPDT or DPDT avail on DPDT(5A per contact) DPDT(5A per contact) special order. ~. TYPICAL ~. + +. 6. WIRING & 5 7. 6. CONNECTION Reset 4. 5 7. 8. 4 5 A1 15 25 4 8 A1 15 Y 1 Y2 Y3.
6 3 6. DIAGRAM Start 3 9 3 9. 2 7. 2 10 2 10. Gate 1 11 1 8 1 11. ~ ~ 16 18 A2 26 28 16 18 A2 Y4. _ ~. _ ~. + +. Power Supply Power Supply ~ AC or DC ~- + Power Supply Power Supply: Power Supply: Power Supply: Power supply: Power Supply: TECHNICAL 230(100 to 250) VAC 230(100 to 250) VAC AC: AC: 250(90-250), 400, 415, AC transformer: wide housing: wide housing: SPECS 24 VAC/DC 24 VAC/DC. 24, 115, 250(90-250)V. 525V 15%. 24, 115, 230(220-240)V. 12 VDC 12 VDC DC: 48, 60, 110V 15%. 45mm wide housing: 45mm wide housing: Consumption: Consumption: Consumption: 30mA. 400(380-415), 525V 400(380-415), 525V. 3VA (100 to 230 VAC), 3VA (100 to 230 VAC), DC: AC/DC: 10 - 30V DC (no isolation): 2VA (24 VAC) 2VA (24 VAC) wide housing: Consumption: 100mA wide housing: 1W (24 VDC) 1W (24 VDC) 48, 60,110V 48, 60,110V.
7 (12 VDC) (12 VDC) AC/DC: Time Ranges AC/DC: wide housing: wide housing: Time Ranges: Time Ranges: 24 (12-24)V ST-100 ST-101 24 (12-24)V. 0-1,8 sec 0-220 sec SCALE SETTING SCALE SETTING Time Specification: 0-7,5 sec 0-7,5 min Time Specification: 1 10 1 10 Setting Accuracy: 5% Setting Accuracy: 5%. 0-15 sec 0-15 min Sec to 1s 1s to 10s Repeatability: Repeatability: Sec to 1s 1s to 10s 0-30 sec 0-60 min Min to 1m 1m to 10m Min to 1m 1m to 10m 0-60 sec 0-120min Time Ranges: Time Ranges: Hrs to 1hr 1hr to 10hrs Hrs to 1hr 1hr to 10hrs 0-120sec 0-240min Time Time Setting: Time Range Time Time Setting: Time Range 10 Hrs 1Hr to 10hrs 10hrs to 100hrs 10 Hrs 1Hr to 10hrs 10hrs to 100hrs Scale 10 to 100% Selection: Scale 10 to 100% Selection: Selection sec, min, hrs Reset Selection sec, min, hrs Timing Functions: Timing Functions.
8 2 to 2 Sec, min, hrs Power supply to be 2 to 2 Sec, min, hrs - Delayed ON, pulse start - Delayed ON, power-up start 5 to 5 Sec, min, hrs interrupted for at least 0,5 5 to 5 Sec, min, hrs - Symmetrical Recycling - Interval (one-shot) 10 1 to 10 Sec, min, hrs seconds 10 1 to 10 Sec, min, hrs (ON or OFF cycle first) operation, power-up start 20 2 to 20 Sec, min, hrs 20 2 to 20 Sec, min, hrs - Signal ON/OFF Delay 50 5 to 50 Sec, min, hrs Timing Functions: 50 5 to 50 Sec, min, hrs - Interval operation 100 10 to 100 Sec, min, hrs - Delayed ON, power-up 100 10 to 100 Sec, min, hrs (hold or pulse start) start Timing Functions: - Interval (one-shot) Timing Functions: Inputs: - Delayed ON, power-up start operation, power-up start - Delayed ON.
9 - Start - Interval (one-shot) - Symmetrical Recycling (hold or pulse start). - Gate operation, power-up start (ON or OFF cycle first) - Interval (one-shot) operation - Reset - Symmetrical Recycling (hold or pulse start). (ON or OFF cycle first). ELECTRONIC TIMERS. QUICK . MULTI-FN STAR-DELTA TIMERS ASYMMETRICAL RECYCLING. PRODUCT ST110/ST111 AT130 ST130 AT200 ST200/ST201. ST112/ST113 Asymmetrical ST202/ST203. Star-Delta Star-Delta Electronic Reset Recycling Timer Asymmetrical Timer Timer Timer (Twin Timer) Recycling Timers ORDERING TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC.
10 RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS TYPE. SUPPLY. VOLTAGE AC/DC. RELAY. CONTACTS. CODE ST110 / 240 AC S AT130 / 250 A S ST130 / 415 AC S AT200 / 250 A D ST200 / 250 AC S. back A1 15 back A1 15 25. FRONT PLATE front A-LINE AT 1 3 0. front A-LINE. Y1 Y2. AT200. Y3. SLIMLINE ST-200. SLIMLINE ST-110 Star-Delta Timer SLIMLINE ST-130. Asymmetrical Recycling Unequal Cycling CONTROLS Electronic Reset Star - Delta Timer Range 2. 6. 20. 120. 60 T1. S1. Timer 40 60. Timer L1 Timer 240 T1. L1 Sec (min). 20 80 P1. 40% +. 70%. L2 Y. T1 10% P1 0% 100%. L = LED 40 60 15 30. L2. Time Set 20. 100%. T2 40 60. 20 80 6 T2. P = Potentiometer + P1.