Transcription of OPERATION MAINTENANCE MANUAL - Tuttnauer USA
1 OPERATION &MAINTENANCEMANUALE lectronic TabletopAutoclavesModels1730, 2340, 2540, 3140, 3850, 3870E, EK, EA & EKA Tuttnauer USA , 25 Power Drive Hauppauge, NY 11788 USA, : (800) 624 5836, (631) 737 4850, Fax: (631) 737 0720e-mail: No. MAN205-0112000EN 1T A B L E O F C O N T E N T SPARAGRAPHPAGE Heating Emission and (Keys and Display).. Light and Functions of the Control Panel of the Display of Displayed Messages and Safety 1. Unwrapped 2. Wrapped Instruments and Porous 3. 4. Accessory (Dry Only).
2 255 PRINTER (Optional).. Water and and Unloading the the Water A B L E O F C O N T E N T S( C o n t i n u e d )PARAGRAPHPAGE and Scheduled the Air Filter (Models EA, EKA).. the the Air the Door the Safety the Water Outlet Tabletop Autoclaves with Chamber Brite .. Sensor FOR THE A B L E O F C O N T E N T S( C o n t i n u e d )DRAWINGSPAGE Panel Keyboard Old Type (Gray)..15 Front Panel Keyboard New Type (Blue).. the Operating Instructions carefully, before beginning any OPERATION onthe autoclave!
3 InspectionUpon receiving your Tuttnauer Autoclave,carefully inspect the outsideofthe shipping carton for signs of damage. If any damage to the carton isfound,note the location with respect to the autoclave and check that areaof the autoclave carefully once it is fully unpacked. Observe packingmethod and retain packing materialsuntil the unit has been inspection involves checking for signs of physical damagesuch as: scratched panel surfaces, broken knobs, any damage is found,contact your dealer as soon as possible so Tuttnauer products are carefully inspected prior to shipment,and allreasonable precautions are taken in preparing them for shipment,to assuresafe arrival at their.
4 Lifting and carrying should always be done by two certify that this instrument is guaranteed to be free from defects inmaterial and workmanship for two years against faulty components warranty does not include routine cleaning and preventivemaintenance to be performed according to instructions insection (Preventive and Scheduled MAINTENANCE ). Tuttnauer warrantees all new autoclaves for a period of two full years,covering both parts and labor. This two year warranty covers defects inmaterials and workmanship oneverypart in theautoclave except doorgaskets and HEPA filters (they are wear items).
5 Tuttnauer warrantees all chambers for a period of ten (10) years againstdefects in materials and workmanship. Thischamber warranty went intoeffect January warranty does not apply to any instrument that has been subjected tomisuse, neglect, accident or improper installation or application, nor shallit extend to autoclaves that have been repaired or altered outside thefactory without prior authorization from s obligation is limited to the repair or replacement of parts forthe the unit is not purchased froman authorized Tuttnauer dealer.
6 Noother warranties or obligations areexpressed or Autoclave should only be used in a manner described in thismanual! StatementTo activate the warranty, the registration card must be completed andreturned to Tuttnauer within fourteen (14) days of purchase or you may callour customer service department at the number listed product will be received or accepted for repair without prior returnauthorization from Tuttnauer . All transportation charges to and fromTuttnauermust be paid by the owner of the autoclave.
7 During the first 90days after purchase of an autoclave, Tuttnauer will pay shipping costs onan individually evaluated basis andONLY with :If you have any questions or there are any difficulties with this instrumentand the solution is not covered in this MANUAL , please contact your dealer orTuttnauer not attempt to service this instrument yourself. TuttnauerUSACo.,Ltd.,25 PowerDriveHauppauge,NY11788,USA : (800)624 5836, (631) 737 4850, Fax: (631) 737 tabletop autoclave is designedas a gravity displacement systemforthe sterilization of wrapped and unwrapped instruments and related itemsfound in dental, medical and veterinary clinics, first aid rooms, hospitals,laboratories, autoclave is an electricallyheated sterilizer using steam as thesterilizing agent.
8 A computerized control unit ensuring a fully automaticsterilization cycle, control and monitoringof physical parameters and aclear documentation of the sterilization cycle controls the autoclave has three automatic programs, according to the material tobe sterilized, and one auxiliary drying program. Models EA and EKA areequippedwith an air compressor that,during the drying stage, draws airthrough a HEPA filter ( m).It pushes that air throughthe heatedchamber to remove moisture and facilitate the drying OPERATION . Drying isperformed with the door all models (except 1730), a water pump is installed between the waterreservoir and the chamber.
9 This pump guarantees fast and accurate fillingof the chamber every time. Entry of water may be accompanied by anoise for approximately 30 seconds. This is normal noise generated byregular OPERATION of the control system provides adequate protection to ensure the safety ofpersonnel and reliable OPERATION with a minimum of shutdown all models (except 1730), a printer is an optional addition to theautoclave. The printer prints the preset and actual parameters of the cycle(temperature, time and pressure).This MANUAL is intended for the user and gives the user a generalunderstanding of the instrument and the best ways to operate and takecare of it in order to obtain optimum effective MANUAL , operating the autoclave will be easy.
10 However,since this instrument is built with high technology sensitive components,no attempt should bemade by the user or any other unauthorized personto repair or recalibrate technical personnel,having proper qualifications and holdingtechnical documentation (including a technician MANUAL ) andadequate information are authorized to servicethe ModeThe autoclave provides an optionof heating the chamber in standbymode between cycles with a very low power in order to reduce total cycletime ( of the total power only). The autoclave turns off automaticallyif the interval between the sterilization cycles is more than 2 hours.