40 Psf
Found 8 free book(s)Fairfax County Typical Deck Details
www.fairfaxcounty.gova 40 PSF live load, 10 PSF dead load, normal loading duration, wet service conditions and deflections of / 360. for main spans and . ℓ / 180 . for overhangs with a 220-pound point load. 3. The use of these details to design and construct multi-level decks is prohibited. MATERIAL SPECIFICATIONS . 1. Lumber shall be preservative-treated, southern
Average Weight (psf) of Completed Walls Using Concrete ...
academic.csuohio.eduat 40" oc 32 43 50 65 38 46 55 71 43 52 61 80 48" oc 31 42 49 63 37 45 54 69 42 51 60 78 26 33 36 47 32 36 41 53 37 42 47 62 Solid Grouted Wall No Grout in Wall 103 pcf 115 pcf 135 pcf Wall Thickness Average Weight (psf) of Completed Walls Using Concrete Masonry Units - Grout Weight = 105 pcf Lightweight Medium Weight Normal Weight No Grout in Wall
430–450 W Commercial A-Series Panels - SunPower
us.sunpower.comTemperature −40° F to +185° F (−40° C to +85° C) Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Appearance Class A Solar Cells 72 Monocrystalline IBC cells Tempered Glass High-transmission tempered anti-reflective Junction Box IP-68, TE (PV4S) Weight 47.7 lbs (21.6 kg) Max. Load
D1E4 Example Solutions - New Jersey Institute of Technology
web.njit.eduthickness ft σ - psf u - psf σ' psf A 0 0 0 0 B 10 103.35×10 = 856.7 0 1033.5 C 5 1033.5+131.97×5=1693.4 62.4×5=312 1381.4 D 15 1693.4+119.65×15=3488 62.4×20=1248 2240 Example 5 For a NC soil in the following data were obtained from a consolidation test: Stress, tsf void ratio 1.30 0.95 3.50 0.70
Technical Services: 888-437-3244 Sales ... - ClarkDietrich
www.itools.clarkdietrich.comProduct Submittal Sheet Technical Services: 888-437-3244 Engineering Services: 877-832-3206 Sales: 800-543-7140 clarkdietrich.com 09.22.16 (Non-Structural Metal Framing)
Lifestyle Series Casement - Pella
media.pella.comWater Resistance 6.06 - 14.62 psf: 7.5 psf Design Pressure: 30 - 50 psf 20 - 50 psf Other Performance Criteria: Forced Entry Resistance Level (Minimum Security Grade) 2. 40. 40: Operating Force (lb) Initiate Motion / Maintain Motion (of Hallmark tested size and glazing) 3 …
Wind Load Vs PSF - Wind Load Vs PSF - Pool Enclosures Inc
poolenclosuresinc.comWind Load Vs. PSF Wind Pressure of Basic Speed is: q= (V^2)/1.6 {V to the power of 2 divided by 1.6} Where q is the pressure in Pa and V is the wind velocity in m/sec. Transferring this to American unit’s yields: q= (V^2)/383.6 where q is the pressure in PSF and V is the velocity in mph. For Example, Speed of 100 mph gives 26.07 PSF.
SPHERICAL DOME FORMULAS - Monolithic Dome Institute
static.monolithic.comExample: 40 foot diameter by 15 foot tall dome. r = 40 2 = 20 feet R c = r2+h2 2h = 202+152 2 15 = 20 20+15 15 30 = 400+225 30 = 625 30 = 20.83 feet w l — is the distance from the base of the dome to a second level (like a second floor). w r l — is the radius of the dome at a second level (l high). This radius is helpful to create a second ...