404a Refrigerant
Found 11 free book(s)Instruction Manual - HOSHIZAKI
www.hoshizaki.comRefrigerant 404A 2 LB. 15 OZ. 404A 1 LB. 10.5 OZ. 404A Total Refrigerant Charge with Hoshizaki Remote Condenser Unit URC-9F: 9 LB. 4 OZ. Three Phase Model Number KM-901MRH3 AC Supply Voltage 208-230/60/3 Compressor 208-230V 5.9RLA 51LRA Pump 120V 0.5FLA 10W
Fundamentals of CO2 Refrigeration - RSES.org
www.rses.orgR-404A has a global warming potential (GWP) of 3,922; CO 2 has a GWP of 1. CO 2, also known as R-744, is con-sidered a natural refrigerant that is non-fl ammable and presents no threat to the ozone layer. In fact, it is the re-frigerant by which the GWP of other refrigerants are measured. So, in terms of GWP, one pound of R-404A emis-
MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM …
www.hoshizaki.comREFRIGERANT CHARGE R-404A, 4 lbs. 0 oz. ( 1800 g ) ( Icemaker 2 lbs. 1.5 oz. Cond. Unit 1 lb. 14 oz. ) DESIGN PRESSURE High 467 PSIG, Low 230 PSIG P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-out ( Internal ) COMPRESSOR PROTECTION Auto-reset Overload Protector ( Internal ) REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
Thermostatic Expansion Valves - - Parker
sporlanonline.com1. Determine the liquid temperature of the refrigerant entering the valve. The TEV capacity tables on pages 4 to 8 are based on a liquid temperature of 100°F for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, and R-507. For other liquid temperatures, apply the correction factor given in the tables for each refrigerant.
CO2 Transcritical Systems Training Manual 042718
www.hussmann.com2 as a refrigerant will be compared to HCFCs such as R-22, and HFCs such as R-404a and R407a, for the purposes of this manual. Other HFO blends such as R448a and R449a will also be compared. The content herein is presented with the assumption that users have knowledge of how these refrigerants operate in direct expansion refrigeration systems.
Line Sizing - Hussmann
www.hussmann.com- R-404A and R-507A Low Temp: Suction Line Sizing - R-404A and R-507A Low Temp: Liquid Line, ... refrigerant system charge as well as extra copper cost. h) It is worth repeating that the connection on a compressor service valve, the size of the connection
CONDENSING UNIT CATALOG For more free Copeland …
www.hvacrinfo.com404a 8770 11600 13000 14500 16100 fjam-a225-cfv, tfc, tfd. 001. 404a 2 1/4 10400 13400 14900 16400 17900 f3ad-b225-cfv, tfc, tfd. 015, 020. 22 11400 13100 15100 17100 19300 21500 23900 26400 f3ad-b301-cfv, tfc, tfd. 015, 020. 22 3 17000 19500 22000 24600 27400 30300 33300 36500 fjam-a300-cfv, tfc, tfd. 001. 404a 13100 17300 19500 21600 23800 ...
Bulletin 210-60 OCTOBER1994 THERMOSTATIC EXPANSION …
www.sporlanonline.comrefrigerant and the second letter (and third if used) the selective charge of the element. Numbers, if used, indicate a special MOP or maximum operating pressure. (For refrigerant identification refer to Section 2). Prior to 1992, the refrigerant code and selective charge designation were stamped on the side of the capillary button on top of the
Refrigerant Piping Handbook - icemeister.net
www.icemeister.netRefrigerant Piping Design Goals The Liquid line must prevent: • formation of flash gas upstream of the metering device. • heat gain to the refrigerant. The refrigerant Condensate line must: • provide sewer-type flow; that is, free draining of liquid refrigerant in one direction, while refrigerant vapour flows adjacent to the liquid in
Refrigerant Table: Explanation and Glossary of Terms
www.hrai.caRefrigerant types: CFC Refrigerant: CFC refers to the chemical composition of the refrigerant. Chlorofluorocarbon indicates that the refrigerant is comprised of Chlorine, Fluorine, and Carbon. Common CFC refrigerants are R-11, R-12, R-13, R-113, R-114, and R-115. A blend that contains a CFC and any other product is still considered a CFC ...
Equipment ID & Nomenclature - Kolpak
www.kolpak.com© Welbilt, Inc. 3 Condensing unit serial tag location. Kolpak/RDI branded tag. Equipment ID