410a Refrigerant

Found 12 free book(s)
Installer’s Guide Condensing Units - Trane

Installer’s Guide Condensing Units - Trane

www.trane.com

These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.

  Refrigerant, Trane, 410a, Refrigerant 410a

INSTALLATION INSTRUCTIONS - Lennox

INSTALLATION INSTRUCTIONS - Lennox

resources.lennox.com

Manifold gauge set used with HFC−410A refrigerant systems must be capable of handling the higher system operating pressures. The gauges should be rated for use with pressures of 0 − 800 psig on the high side and a low side of 30" vacuum to 250 psig with dampened speed to 500 psi. Gauge hoses must be rated for use at up to 800

  Refrigerant, 410a, Refrigerant 410a

Phasing out HCFC refrigerants to protect the ozone layer

Phasing out HCFC refrigerants to protect the ozone layer

www.epa.gov

both R-22 and alternative (R-410A) systems. cost, and the refrigerant used. The most common alternative to R-22 is R-410A, a non-ozone-depleting HFC refrigerant blend. R-410A is manufactured and sold under various trade . names, including GENTRON AZ-20®, SUVA® 410A, and PURON®. EPA reviews alternative refrigerants and maintains a

  Refrigerant, 410a

Heat Pumps - American Standard Air

Heat Pumps - American Standard Air

www.americanstandardair.com

Refrigerant R-410AR-410A R-410A R-410A R-410A R-410A R-410A 12 Year Limited Warranty on Compressor with registration* • • • ...

  Refrigerant, 410a

SERVICE MANUAL R 410A Ductless Split System Air ...

SERVICE MANUAL R 410A Ductless Split System Air ...

icpindexing.toddsit.com

Refrigerant Name of Refrigerant R410A R410A Weight Oz. 45.5 45.5 Connection Pipe Length (m) Ft. 16 16 Gas Additional Charge Oz/ft 1.1613 1.1613 Liquid Pipe Diameter inch Gas Pipe Diameter inch 3/8 3/8 Max. Interunit height Difference Ft. 33 33 Max. Interunit Piping Length Ft. 66 66 * The above data is subject to change without notice.

  Refrigerant, 410a

UNDERSTANDING REFRIGERANT TABLES - RSES

UNDERSTANDING REFRIGERANT TABLES - RSES

www.rses.org

future. However, all other refrigerant tables work essentially the same way as the R-22 example. This chapter will review the older refrigerant (R-22) first, and then refer to one of the newer replacement refrigerants (R-410A). As you study their characteris-tics, known problems, limitations, etc., remember that this is a field of rapid change.

  Refrigerant, 410a

Product and Serial Number Nomenclature

Product and Serial Number Nomenclature

www.virginiaair.com

2 Refrigerant/Meter 4 = R-410A TXV 2 = R-22 TXV 3 = Flex Coil (No expansion device) A TXV Indicator A = Valve size 1 B = Valve size 2 3 = Valve size 3 X = No valve N Options H = Horizontal Pan (Factory Installed) N = No Options 1 Generation A Series MA Type MA = Modular Air Handler MV = Modular Varable Speed 08 = 800 CFM 16 = 1600 CFM

  Refrigerant, 410a

Refrigerant Piping Manual - Mechanical Concepts

Refrigerant Piping Manual - Mechanical Concepts

www.mechanicalconceptsllc.com

For HFC−410A recommended adding oil to system based on the amount of refrigerant charge in the system. (No need to add oil in systems with 20 lbs of refrigerant or less. For systems over 20 lbs − add 1 ounce of every 5 lbs of refrigerant) HCFC−22 Total equivalent length = 240 feet (Piping & all fittings, etc) NOTE − Length is general guide.

  Refrigerant, 410a

Product Data - Carrier

Product Data - Carrier

www.shareddocs.com

with Puronr Refrigerant 1---1/2 to 5 Tons Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HPB6 has been designed utilizing Carrier’s non--ozone depleting Puron refrigerant. This product has been designed and manufactured to meet Energy

  Refrigerant

HS26-060-1P GCS16-090-350-2Y - Lennox

HS26-060-1P GCS16-090-350-2Y - Lennox

www.lennox.com

CBX**M Coil blower multi position R-410A CBX**MV Coil blower multi position variable speed blower R-410A CH Evaporator coil (horizontal flow) COWB Oil fired hot water boiler CP Heat pump coil CR Evaporator coil (reverse or down flow) DX Direct expansion (cooling) E Electric furnace ED Electric duct heater (horizontal or up flow)

  Gcs16, 410a, Lennox, Hs26, Hs26 060 1p gcs16 090 350 2y

Cased and Uncased Heat Pump / Cooling Coils 1 1/2 - Trane

Cased and Uncased Heat Pump / Cooling Coils 1 1/2 - Trane

www.trane.com

Cased and Uncased Heat Pump / Cooling Coils 1 1/2 - 5 Ton 2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH 13 SEER Heat Pump /Cooling Coils for R-22 and R-410A PUB. NO. 22-1773-01

  Trane, 410a

Refrigerant Piping Handbook - icemeister.net

Refrigerant Piping Handbook - icemeister.net

www.icemeister.net

Refrigerant Piping Design Goals The Liquid line must prevent: • formation of flash gas upstream of the metering device. • heat gain to the refrigerant. The refrigerant Condensate line must: • provide sewer-type flow; that is, free draining of liquid refrigerant in one direction, while refrigerant vapour flows adjacent to the liquid in

  Refrigerant