410a Refrigerant
Found 12 free book(s)Installer’s Guide Condensing Units - Trane
www.trane.comThese units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.
INSTALLATION INSTRUCTIONS - Lennox
resources.lennox.comManifold gauge set used with HFC−410A refrigerant systems must be capable of handling the higher system operating pressures. The gauges should be rated for use with pressures of 0 − 800 psig on the high side and a low side of 30" vacuum to 250 psig with dampened speed to 500 psi. Gauge hoses must be rated for use at up to 800
Phasing out HCFC refrigerants to protect the ozone layer
www.epa.govboth R-22 and alternative (R-410A) systems. cost, and the refrigerant used. The most common alternative to R-22 is R-410A, a non-ozone-depleting HFC refrigerant blend. R-410A is manufactured and sold under various trade . names, including GENTRON AZ-20®, SUVA® 410A, and PURON®. EPA reviews alternative refrigerants and maintains a
Heat Pumps - American Standard Air
www.americanstandardair.comRefrigerant R-410AR-410A R-410A R-410A R-410A R-410A R-410A 12 Year Limited Warranty on Compressor with registration* • • • ...
SERVICE MANUAL R 410A Ductless Split System Air ...
icpindexing.toddsit.comRefrigerant Name of Refrigerant R410A R410A Weight Oz. 45.5 45.5 Connection Pipe Length (m) Ft. 16 16 Gas Additional Charge Oz/ft 1.1613 1.1613 Liquid Pipe Diameter inch Gas Pipe Diameter inch 3/8 3/8 Max. Interunit height Difference Ft. 33 33 Max. Interunit Piping Length Ft. 66 66 * The above data is subject to change without notice.
UNDERSTANDING REFRIGERANT TABLES - RSES
www.rses.orgfuture. However, all other refrigerant tables work essentially the same way as the R-22 example. This chapter will review the older refrigerant (R-22) first, and then refer to one of the newer replacement refrigerants (R-410A). As you study their characteris-tics, known problems, limitations, etc., remember that this is a field of rapid change.
Product and Serial Number Nomenclature
www.virginiaair.com2 Refrigerant/Meter 4 = R-410A TXV 2 = R-22 TXV 3 = Flex Coil (No expansion device) A TXV Indicator A = Valve size 1 B = Valve size 2 3 = Valve size 3 X = No valve N Options H = Horizontal Pan (Factory Installed) N = No Options 1 Generation A Series MA Type MA = Modular Air Handler MV = Modular Varable Speed 08 = 800 CFM 16 = 1600 CFM
Refrigerant Piping Manual - Mechanical Concepts
www.mechanicalconceptsllc.comFor HFC−410A recommended adding oil to system based on the amount of refrigerant charge in the system. (No need to add oil in systems with 20 lbs of refrigerant or less. For systems over 20 lbs − add 1 ounce of every 5 lbs of refrigerant) HCFC−22 Total equivalent length = 240 feet (Piping & all fittings, etc) NOTE − Length is general guide.
Product Data - Carrier
www.shareddocs.comwith Puronr Refrigerant 1---1/2 to 5 Tons Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HPB6 has been designed utilizing Carrier’s non--ozone depleting Puron refrigerant. This product has been designed and manufactured to meet Energy
HS26-060-1P GCS16-090-350-2Y - Lennox
www.lennox.comCBX**M Coil blower multi position R-410A CBX**MV Coil blower multi position variable speed blower R-410A CH Evaporator coil (horizontal flow) COWB Oil fired hot water boiler CP Heat pump coil CR Evaporator coil (reverse or down flow) DX Direct expansion (cooling) E Electric furnace ED Electric duct heater (horizontal or up flow)
Cased and Uncased Heat Pump / Cooling Coils 1 1/2 - Trane
www.trane.comCased and Uncased Heat Pump / Cooling Coils 1 1/2 - 5 Ton 2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH 13 SEER Heat Pump /Cooling Coils for R-22 and R-410A PUB. NO. 22-1773-01
Refrigerant Piping Handbook - icemeister.net
www.icemeister.netRefrigerant Piping Design Goals The Liquid line must prevent: • formation of flash gas upstream of the metering device. • heat gain to the refrigerant. The refrigerant Condensate line must: • provide sewer-type flow; that is, free draining of liquid refrigerant in one direction, while refrigerant vapour flows adjacent to the liquid in