Attic Rafter
Found 7 free book(s)raft-R-mate Attic Rafter Vent Brochure - Owens Corning
www.owenscorning.com® Attic Rafter Vent with optional air stop/insulation block • Ventilation channel and air stop/insulation block in one easy to install product. • Assists in the constant flow of fresh air from soffit vent to attic. • Aids in reducing energy loss, moisture build-up
Roofs and Walls CAD Details
www.autocaddetails.netend rafter stops @ frieze --_/ block nailer---~ verge ~-rafter ~--sheathing w-----,siding common "-----rafter abbreviated rake samples from www.autocaddetails.net. 3" larger than opening 2 x 10 insulation baffle attic access hatch 22 1/2" x 30" opening i i ~ ~ sht. rock panel i / metal corner bead samples from www.autocaddetails.net. stainless ...
Trussed Rafter - DJR Roof Trusses
www.djr-roof-trusses.co.ukRAFTER LOADS Long Term Loads:For standard concrete interlocking tiles the loads are as follows: Tile weight 575 N/m 2 Truss self weight 75 N/m 2 Battens & felt 35 N/m 2 685 N/m2 Where a rafter bay forms part of the room (in raised tie and attic trusses) an additional load of 250 N/m2 is added for the ceiling finishes. Medium Term Loads:For ...
Appendix: Ridge Vent/Soffit Vent Calculator for Standard ...
www.bestmaterials.comOnce attic square footage is known, divide by 150 (for the 1/150 ratio). That determines the total amount of net free area needed to properly ventilate the attic. Calculation: 3. Determine the amount of intake and exhaust ... enclosed rafter spaces formed where ceilings are …
Basic Roof Framing 17
wilswood.weebly.comcommon rafter, using at least one of the four ... A gambrel roof allows for more useable attic space than a typical gable or hip roof. This space can also be used as a second fl oor. Mansard Roof The mansard roof is a variation of the hip roof. It has steep slopes on all four sides.
Guidelines for asphalt shingle roofing
www.dli.mn.govlocated in the upper portion of the attic or rafter space. Upper ventilators can be located no more than 3 feet below the ridge or highest point of the space, measured vertically. The balance of the required ventilation must be located in the bottom one …
The Chronicles of Narnia 1 - The Magicians Nephew
mscerdasenglish.weebly.comthe slates. There was no floor in this tunnel: you had to step from rafter to rafter, and between them there was only plaster. If you stepped on this you would find yourself falling through the ceiling of the room below. Polly had used the bit of the tunnel just beside the cistern as a smugglers' cave. She had brought up bits of old