Deck Screws
Found 9 free book(s)Product Specification Manual - Screws
www.grabberman.comJan 05, 2005 · 286 AnyDeck Stainless Steel Composite Screws, Designed and engineered to work with all types of composite materials where surface mounted LOX® Drive fasteners are recommended. DM105 ®Deckmaster Deck Board Screws For fastening Deckmaster® brackets to deck boards DM110 ®Deckmaster Joist Screws For fastening Deckmaster® brackets to joists
SDI MANUAL OF CONSTRUCTION WITH STEEL DECK
www.sdi.orgDeck is typically attached to the building frame with arc puddle welds, self drilling screws or powder or pneumatically driven pins. Sheet to sheet fastening is done with screws, button punching (crimping), or welds. 2. Composite Floor Deck After installation and adequate fastening, floor deck serves
DOMESTIC DECK DESIGN GUIDE - TasmanKB
www.tasmankb.com.auScrews used normally for ti mber decks are not suitable for fi xing decking to steel joist due to the seasonal and diff erenti al expansion and contracti on of ti mber decking and steel substructure may cause the screws to fail in shear. It is recommended that a ti …
AMERICAN NATIONAL STANDARDS INSTITUTE/ STEEL DECK ...
www.sdi.orgshall be attached to supporting framing using #12 screws in a 36/7 pattern. (4) #10 sidelap screws shall be installed per deck span." 2. Products 2.1 Material: A. Sheet steel for deck shall conform to AISI S100, Section A3, as modified in Section 2.1.C. User Note: AISI S100, Section A3.1 notes an exception that "For steels used in
Modified Bitumen Roofing Membranes
www.jm.comNon-Nailable Deck Types: Steel Decks. Steel deck must be 22 gauge at a min-imum and have a shop coat of priming paint. Galvanized steel is recommended. Steel deck units should be welded or, preferably mechanically fastened to the structural frame with a minimum of weld holes. Side laps should be fas-tened with sheet metal screws on not over 3 ...
DECK CONSTRUCTION GUIDELINES FOOTINGS
www.soduspoint.infoDeck screws may not be used on any metal connectors. All nails and connectors used with pressure treated lumber must be designed for pressure treated lumber in order to prevent decay of the fastener. - Post to Concrete Footing Simpson ABEFF or Equal
Prescriptive Residential Wood Deck Construction Guide
www.awc.orglag screws are specified for various connections. Edge distance and spacing requirements are based on ½" diameter fasteners. If larger (or smaller) fasteners are specified, edge distance and spacing shall be adjusted. 7. To resist corrosion, the following is required [R317.3]: All screws, bolts, washers, nuts, and nails for use
SECTION R507 DECKS - iccsafe.org
iccsafe.orgDeck construction shall be capable of accommodating all vertical and horizontal loads in accordance with ... (13 mm) diameter lag screws or through bolts with washers at a spacing specified in Section R507.9.1.4 and as shown in Figure R507.9.1.1. The exterior finish material shall be removed prior to installation of the ledger board.
Appendix B provides an acceptable method of designing a ...
dsps.wi.govAppendix B provides an acceptable method of designing a deck, at the owner’s option. It is mainly ... 1/2 inch−diameter bolts and lag screws are specified for various connections. Edge distance and spacing requirements are based on 1/2 inch−diameter fasteners. If larger (or smaller)