Interpreting DMA curves, Part 1 - Mettler Toledo

Interpreting DMA curves, Part 1 - Mettler Toledo

www.mt.com

- Shear for samples with a shear modu-lus in a very large range from about 1 kPa to 2 GPa. This allows viscous liquids and even solid samples, e.g. polymers in the glassy state, to be measured. - Three-point bending for stiff samples with a modulus of elasticity of up to 1000 GPa. - Single and dual cantilever bending

  Samples, Part, Part 1, Interpreting, Curves, Interpreting dma curves

DSC Measurement of Polypropylene - Hitachi High-Tech

DSC Measurement of Polypropylene - Hitachi High-Tech

www.hitachi-hightech.com

Figure 1 shows the DSC curves for measurement condition 1. All samples showed an endothermic peak due to PP melting around 160℃. Furthermore, on the low temperature side of the endothermic peak, the untreated sample showed a smooth DSC curve between 110 and 125℃ while the treated samples showed a minute peak.

  Measurement, Samples, Polypropylene, Dsc measurement of polypropylene

DYNAMIC-MECHANICAL PROPERTIES OF POLYMERS

DYNAMIC-MECHANICAL PROPERTIES OF POLYMERS

www.eng.uc.edu

LeBrun samples tan (x 10-1) Modulus (Pa x 10 9) AMP good part 20% glass filled Nylon 6/6 Temperature (C) KPM Curve 1: DMA Temp/Time Scanin 3 Point Bending File info: AMP66gp.1Tue Oct 26 16:05:29 1993 Frequency: 1.00 Hz Dynamic Stress: 190.0mN LeBrun samples Static Stress: 200.0mN PERKIN-ELMER 7 Series ThermalAnalysis System

  Samples

Interpreting Unexpected Events and Transitions in DSC …

Interpreting Unexpected Events and Transitions in DSC

www.tainstruments.com

Keep hygroscopic samples in a dessicator and load them into pans in a dry box. Weigh the complete sample pan (with sample) before and after the run. A change in weight could explain an unexpected transition. Figure 6: DSC transition due to moisture in the purge gas …

  Samples, Events, Transition, Interpreting, Unexpected, Interpreting unexpected events and transitions

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER …

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER …

faculty.olin.edu

DSC instrument works in conjunction with a controller and associated software to allow for data acquisition and analysis. Safety The following labels are displayed on the DSC instrument for your protection: Hot Stuff. The DSC is capable of heating samples to 600°C. During testing, the furnace assembly becomes noticeably hot.

  Samples

1/2000 - University of Cincinnati

1/2000 - University of Cincinnati

www.eng.uc.edu

1) Samples of irregular form can topple over in the pan. 2) Polymer films that have not been pressed against the base of the pan first change shape (no longer lie flat) on initial warming. Afterward, on melting, they make good contact with the pan (Fig. 2). b)An abrupt change of the heat transfer between the pan and the DSC sensor:

  Samples

Interpreting Unexpected Events and Transitions in DSC Results

Interpreting Unexpected Events and Transitions in DSC Results

www.tainstruments.com

Keep hygroscopic samples in a dessicator and load them into pans in a dry box. Weigh the complete sample pan (with sample) before and after the run. A change in weight could explain an unexpected transition. Figure 6: DSC transition due to moisture in the purge gas Dry the purge gas by placing a drying tube in the line.

  Samples

ACCESSORIES, PARTS, & CONSUMABLES

ACCESSORIES, PARTS, & CONSUMABLES

www.tainstruments.com

900825.902 High Volume DSC Sample Pans, Lids, and Seals (pkg. of 100) 900824.901 High Volume DSC Sample Pan Die Set (for Standard DSC Press) 900870.901 Aluminum DSC Sample Pans for SFI Samples (pkg. of 200) 900867.901 Copper Sample Pans, DSC (pkg. of 200) 900866.901 Gold Sample Pans*, DSC (pkg. of 10) 900868.901 Gold Lids*, DSC (pkg. of 10)

  Samples

Sensorless Field Oriented Control (FOC) of a Permanent ...

Sensorless Field Oriented Control (FOC) of a Permanent ...

ww1.microchip.com

Jan 05, 2010 · DSC takes advantage of peripherals specifically suited for motor control (motor control PWM and high-speed ADC) to execute sensorless field oriented control of a PMSM. The DSP engine of the dsPIC DSC supports the necessary fast mathematical operations. Data Monitoring and Control Interface The Data Monitor and Control Interface (DMCI) pro-

  Control, Field, Oriented, Sensorless, Sensorless field oriented control