Lintels

Found 6 free book(s)
PRECAST CONCRETE LINTELS - Masolite

PRECAST CONCRETE LINTELS - Masolite

www.masolite.com

Lintels are marked on the top to be sure reinforcing steel is correctly placed. Lintels are designed in accordance with IBC 2009, ASCE 7-10, ACI 318-08, NCMA TEK 17-2A and NCMA Lintel Design Manual 2004. See load tables for materials properties and design parameters. Lintels are lightweight

  Lletin

Single Leaf Wall Lintels - CCS - Catnic

Single Leaf Wall Lintels - CCS - Catnic

catnic.com

CCS lintels are fully built into wall construction for use with single leaf face brick or block walls. Channel Sections Standard Duty CCS lintels should be suitably propped and laterally restrained during construction. Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at 3000mm to 4800mm. Standard lengths (mm)

  Walls, Single, Leaf, Lletin, Single leaf wall lintels ccs

Building Code Title 27 Subchapter 5 - New York City

Building Code Title 27 Subchapter 5 - New York City

www.nyc.gov

Oct 01, 2004 · §[C26-502.4] 27-326 Lintels. - Lintels over openings wider than four feet in masonry walls, other than in walls of masonry veneer on wood frame structures, shall be fire protected as required by section 27-324 of this article for structural members, when the full load over the opening is not relieved by a masonry arch of required strength. The

  York, New york city, City, Lletin

CHAPTER 6 WALL CONSTRUCTION - ecodes.biz

CHAPTER 6 WALL CONSTRUCTION - ecodes.biz

ecodes.biz

may be omitted over lintels that are adequately tied to adjacent wall sections with steel plates or equivalent as previously described. 2011 OREGON RESIDENTIAL SPECIALTY CODE 6-1 > > 1 M:\data\CODES\STATE CODES\Oregon\2011\Residential\Final VP\06_Oregon_Res_2011.vp Monday, May 02, 2011 1:58:00 PM Color profile: Generic CMYK printer profile

  Lletin

MEMBER TABLES F17 - ASH

MEMBER TABLES F17 - ASH

ash.com.au

Lintels to internal wall openings supporting ceiling joists only may be sized as hanging beams. Lintel Size Depth x Breadth (mm) Rafter or Truss Spacing (mm) SEASONED HARDWOOD — F17 Roof Load Width (mm) 1500 2100 4500 7500 5 10 20 5 10 20 5 10 20 5 10 20 MAXIMUM SPAN OF LINTEL (mm)

  Lletin

Design and Analysis of Concrete Masonry and Precast ...

Design and Analysis of Concrete Masonry and Precast ...

ncma.org

Lintel Design Manual v t = thickness, in. V c = nominal shear strength provided by concrete, lb. V m = shear strength provided by masory masonry, lb. V n = nominal shear strength of a cross-section before application of strength reduction factor, lb. V r = resisting shear of lintel, lb. V s = shear strength provided by shear reinforcement, lb. w = load per unit length, lb/ft.