Seismic Ceiling Installation
Found 8 free book(s)USG Exterior Ceiling Systems Installation Guide (English ...
www.usg.comMark the finished ceiling height and set your laser at 2-1/8 in. above the ceiling height to indicate the top of the U-2-3/32 perimeter molding. Note: For seismic installations, use M20A perimeter molding at the finished ceiling height. Refer to the Seismic Perimeter Applications section in the USG Exterior Ceiling Systems Guide, SC2561. 2-1/8"
Assembly and Installation Instructions
www.armstrongceilings.com3.1 Non-seismic installation If WoodWorks Grille panels weigh in excess of 2.5 lbs/SF, the ceiling shall be installed per CISCA seismic zones 3-4, as modified by the IBC. WoodWorks Grille slats install perpendicular to the main beams. The main beams shall be spaced 48" O.C. The 48" cross tees shall
SEISMIC CEILING INSTALLATION - Armstrong Ceiling S
www.armstrongceilings.comNOTE: Seismic categories are determined for the entire building. This is why the Seismic Design Category information is on the structural drawings. SUMMARY OF IBC SEISMIC INSTALLATION REQUIREMENTS IBC CATEGORY IBC INSTALLATION REQUIREMENTS A, B Ceiling installation should conform to basic minimums established in ASTM C636.
Design Manual Keylock Ceiling System - Home | Rondo
www.rondo.com.auinstallation details: • suspended ceilngs: non-fire rated 11 • control joints 14 • external suspended ceiling system 15 • direct fixing of furring channel battens 16 • bulkhead installations 17 bulkheads 18 • curved ceilings 19 • raked & cantilevered ceilings 20 metal ceiling battens domestic 21
SUSPENDED CEILINGS Suspension Systems for Acoustical Lay ...
www.nwcb.org• Seismic splay wires are to be four 12-gauge wires attached to the main beam. Wires are arrayed 90° from each other and at an angle not exceeding 45° from the plane of the ceiling. Source: ASTM E580 Section 5.2.8.2 • Seismic splay wires shall be attached to the grid and to the structure in such a manner that they can support a minimum
USG Exterior Ceiling Systems SYSTEMS GUIDE
www.usg.comthe installation of each USG exterior ceiling system. USG exterior assemblies were tested per UL 580, UL 1897, TAS 202, and TAS 203, and listed in PEI Evaluation Report, PER-12055.
Seismic Construction Handbook - Sound Concepts
www.soundconceptscan.comSeismic Design Category The requirements for a suspended ceiling are determined by the buildings Seismic Design Category. Determination of the Seismic Design Category is complex and must be determined by a Registered Architect or Professional Engineer and should be found in the construction docu-mentation.
Forward-Curved
content.greenheck.comSeismic Testing Criteria All Greenheck seismically certified models have been tested using the most severe seismic event that is found on the Spectral Response Map per IBC Figures 1613.5 (1-2). Our testing is performed under the worst-case scenario using the highest mapped seismic load, highest level occupancy category, worst-case