Single Pole Double Throw
Found 8 free book(s)The all-in-one proximity sensor and limit switch.
www.emerson.comSingle Pole Double Throw (SPDT) 3A/240VAC, 6A/120VAC, 2A/24VDC •-50 °C to +105 °C (-58 °F to +221 °F) 6 mm (1/4 in) Sensing Distance (Ferrous metal) Dry Contact Intrinsically Safe End sensing Gold Plated Contacts • Stainless Steel Enclosure • Lead Wires or Cables • Quick Disconnects - Micro or Mini CSA/FM Hazardous Area Approvals
Cleveland Institute of Electronics Electronics Symbols ...
www.cie-wc.eduopst (double pole, single throw) spot (single pole, double throw dpdt (double pole , double throw —o pushbutton, momentary make or break pushbutton , momentary transfer o pushbutton , maintained contact solenoid switch temperature actuated switch vacuum or pressure actuated switch wafer or rotary switches flow switch the following symbols: nc.
A19 Series Remote Bulb Control Catalog Page
cgproducts.johnsoncontrols.comSingle-Pole, Double-Throw (SPDT) Selection charts Specify the control model code number, packing nut code number (if required), and bulb well code number (if required). Table 1: A19 Series Remote Bulb Control selection chart Product code number Switch action Range °F (°C) Differential F° (C°) Bulb and capillary Bulb well no. (order separately)
Series 1950 Explosion-Proof Differential Pressure Switches
www.dwyer-inst.comSwitch Type: Single-pole double-throw (SPDT). Electrical Rating: 15 A @, 125, 250, 480 VAC, 60 Hz. Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz. Electrical Connections: 3 screw type, common, normally open and normally closed. Process Connections: 1/8˝ female NPT. Mounting Orientation: Diaphragm in vertical position. Consult factory
Disconnect switches - ABBSales.com
abbsales.com12 = 1 pole to left, 2 poles to right of mechanism 13 = 1 pole to left, 3 poles to right of mechanism Special Configuration C = Double throw switch All OT200_, 400_, and 600_ switches are cUL98 listed. Selector Handles OHB S 1 P H Handle Color B = black Y = Red/Yellow Physical Size Connection to Switch A = external shaft P = snap on R = screw ...
Safety switches design guide - Eaton
www.eaton.comDouble- throw Max. 600 Vac horsepower rated Fusible Cartridge H a T (600 V) J L 30–400 400 600 800–1200 2 and 3 Yes Yes Yes up to 600 A c — Yes up to 400 A — Yes up to 400 A — Non-fusible — — 30–1200 2, 3, 4 and 6 Yes Yes Yes up to 800 A c — Yes up to 600 A — Yes up to 600 A — Shunt trip Single-throw max. 600 Vac ...
Series M Miniature Toggles Toggles A General ...
www.nkkswitches.comdouble pole base. External connection must be made during field installation. The DP3T model utilizes a four pole base. (out) (out) (out) (out) (out) (out) External Conn Common (in) Common (in) 1 2 10 7 4 12 96 3 11 8 5 (out) 63 2 4 1 5 (out) (out) External Conn Common (in) POLES & CIRCUITS. Toggle Position ( ) = Momentary. Connected Terminals ...
High noise immunity 74HC4053; 74HCT4053 • JESD8C (2.7 V …
assets.nexperia.comNexperia 74HC4053; 74HCT4053 Triple 2-channel analog multiplexer/demultiplexer 001aae125 1Y0 12 1Y1 S1 13 11 10 S2 9 S3 6 E 2Y0 2 2Y1 1 3Y0 5 3Y1 3 3Z 4 2Z 15 1Z 14 ...