PIPELINE DESIGN MANUAL 2017 - WSSC Water

PIPELINE DESIGN MANUAL 2017 - WSSC Water

www.wsscwater.com

Apr 19, 2017 · The Washington Suburban Sanitary Commission's Pipeline Design Manual covers the minimum standard criteria to be followed by Designers and Engineers when preparing plans and/or specifications for the design of water and sewer pipelines for the Washington Suburban Sanitary Commission (WSSC) within the Washington Suburban Sanitary District …

  Commission, Water, Washington, Suburban, Sanitary, Wssc water, Wssc, Washington suburban sanitary commission

ICTを活用した 水道事業の新たな展開

ICTを活用した 水道事業の新たな展開

www.waterworks.metro.tokyo.lg.jp

高度メーター計量インフラのメリット(米国・WSSCの資料から) AMI:Advanced Metering Infrastructure 25 /32. 2)))))

  Wssc, Ictを活用した

FOOD SERVICE FACILITY LICENSE APPLICATION

FOOD SERVICE FACILITY LICENSE APPLICATION

www.montgomerycountymd.gov

WSSC City of Rockville Poolesville WORKERS’ COMPENSATION INSURANCE COMPANY NAME AND POLICY/BINDER NO: (Required every renewal). (NAME OF INSURANCE COMPANY) (POLICY/BINDER NO.)

  Wssc

Master List of Building Codes and Standards

Master List of Building Codes and Standards

www.montgomerycountymd.gov

WSSC Plumbing & Fuel Gas Code N/A 03-01-2019 Residential Building & Mechanical ICC International Residential Code/2018 MBRC . Maryland Building Rehabilitation Code ER 31-19 State Adoption . 05-20-2020 03-25-2019 ; Residential Sprinklers NFPA 13D/2013 COMAR . NFPA; 13D/2013 ER 7-16 State Fire Prevention Code . 01-08-2016

  Wssc

VICTORIAN GOVERNMENT SECONDARY SCHOOLS

VICTORIAN GOVERNMENT SECONDARY SCHOOLS

www.study.vic.gov.au

Wodonga Senior Secondary College www.wssc.vic.edu.au Disclaimer: The information contained in this document is correct at the time of publication (08/02/2022). This …

  Wssc

17. Manhole Channel Design. - WSSC Water

17. Manhole Channel Design. - WSSC Water

www.wsscwater.com

f) Evaluate drops across pipe inverts larger than 0.1 foot for hydrogen sulfide generation, see Part Two, Section 28 (Hydrogen Sulfide (H2S) Control) and Part Two, Section 16 (Manhole Drop Connections). c. Radius of the Channel. 1) For sewer pipelines smaller than 12-inch diameter, provide a minimum radius of the centerline of

  Control, Water, Hydrogen, Hydrogen sulfide, Sulfide, Wssc water, Wssc

12. Allowable Joint Deflections. - WSSC Water

12. Allowable Joint Deflections. - WSSC Water

www.wsscwater.com

Allowable Joint Deflections WATER DESIGN GUIDELINES 2008 W-12.1 12. Allowable Joint Deflections. a. General. 1) When it is necessary to deflect pipe from a straight line in either the horizontal or vertical plane, the amount of joint deflection shall not exceed the allowable joint deflections as shown in Tables ...

  Water, Deflection, Wssc water, Wssc

24. Force Main Design. - WSSC Water

24. Force Main Design. - WSSC Water

www.wsscwater.com

b) Design the thrust restraint, in accordance with Part Three, Section 27 (Thrust Restraint Design for Buried Piping). 4) Design criteria for AWWA C900 PVC. a) Design the PVC C900 pipeline without curves using fittings only. See Part One, Section 12 (Allowable Joint Deflections) and Part One, Section 14 (Joint Deflections at Fittings).

  Design, Water, Part, Wssc water, Wssc

15. Pipe Slope and Manhole Distance. - WSSC Water

15. Pipe Slope and Manhole Distance. - WSSC Water

www.wsscwater.com

see Sketch "T" and Part Two, Section 16 (Manhole Channel Design) or design a manhole drop connection at the manhole, see Part Two, Section 16 (Manhole Drop Connections). 2) If the slope cannot be reduced, specify AWWA C900 PVC pipe, see the Specifications for 12-inch and smaller sewer pipelines.

  Water, Channel, Wssc water, Wssc

Three Part, Section 4. Buoyancy of Pipelines ... - WSSC Water

Three Part, Section 4. Buoyancy of Pipelines ... - WSSC Water

www.wsscwater.com

Three Part, Section 4. Buoyancy of Pipelines COMMON DESIGN GUIDELINES 2008 C-4.5 Where: Wt = resultant buoyant force of the submerged pipe, pounds per linear foot wI = average unit weight of inundated backfill, pounds per cubic foot Bc = outside pipe diameter, feet HI = depth of inundated backfill above top of pipe, feet HIm = minimum depth of inundated backfill required …

  Guidelines, Water, Wssc water, Wssc