STANDARD DETAILS FOR WATER MAIN INSTALLATIONS
www.chicago.govwater main pipe d.i.p. with push-on joints (in.) pipe diameter (in.) 4 6 8 12 16 24 14 17 21 29 37 53 16 20 24 30 37 53 notes: 1. use one length of polyethylene tube wrap for each length of pipe, overlapped at pipe joints and fold excess over top of tube for slack reduction. 2. use chart "a" to select size of wrap.
Water Main Specs and Details - Charlotte, North Carolina
charlottenc.govAll 1-1/2" and 2" water main pipe shall be PVC 1120 in accordance with ASTM D-2241. The pipe shall be minimum Pressure Class 200 with a SDR of 14 or less for C-900 pipe and a SDR of 21 or less for ASTM 2241 pipe. PVC Pressure Pipe shall be made from white or blue pigmented virgin materials and shall be furnished in lengths of 20 feet.
Water Tanks & System Distribution
www.tad.usace.army.milsmall water main pipe diameters increase the booster pump horsepower requirements, energy costs for operation, and ultimately make water system sustainability more of an issue. 1) Pipe diameters and velocities. The minimum pipe diameter in the distribution system shall