Search results with tag "Synthes"
Inventory Control Form - synthes.vo.llnwd.net
synthes.vo.llnwd.net5.0 mm Ti Locking Screws with ... Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322 To order (Canada): 855-946-8999
3.5 mm LCP Hook Plate. Part of the Synthes locking ...
synthes.vo.llnwd.netSharp hooks Aid in placement of the plate 3.5 mm LCP Hook Plate. Part of the Synthes locking compression plate (LCP) system. 2 Synthes 3.5 mm LCP Hook Plate Technique Guide Precontoured
Surgical Technique - synthes.vo.llnwd.net
synthes.vo.llnwd.net2 DePuy Synthes Cable System Surgical Technique Cable System. For Orthopaedic Trauma Surgery. The Synthes Cable System is primarily a …
Tibial Nail ADVANCED - synthes.vo.llnwd.net
synthes.vo.llnwd.net2 DePuy Synthes Surgical Technique Semi-extended Parapatellar Approach 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation1,2.
Expert TN. Tibial Nail. - synthes.vo.llnwd.net
synthes.vo.llnwd.net1 4 2 3 4 DePuy Synthes Expert Tibial Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation1, 2. 1 Müller ME, M Allgöwer, R Schneider, H Willenegger.
LCP Locking Compression Plate - synthes.vo.llnwd.net
synthes.vo.llnwd.netLocking Compression Plate (LCP) Implants are intended for temporary fixation, correction or stabilization of bones in various anatomical regions. This Surgical Technique applies to the Depuy Synthes LCP Locking Compression Plate Systems and product lines listed below, which include but are not limited to the following indications: Indications
Modular Mini Fragment LCP System - synthes.vo.llnwd.net
synthes.vo.llnwd.netPlates with locking compression technology Locking and cortex screws Instruments designed for use ... Synthes 3 2.0 mm LCP Plates Stainless Steel Titanium Holes Length (mm) ... Titanium Description 247.349 447.349 7 holes shaft, 54 mm 2.0 mm LCP Adaption Plate 247.362 447.362 12 holes, 81 mm 2.0 mm LCP T-Plate 247.615 447.615 3 holes head, 7 ...
VA-LCP Olecranon Plates 2.7/3.5 ... - synthes.vo.llnwd.net
synthes.vo.llnwd.net6 DePuy Synthes VA-LCP Olecranon Plates 2.7/3.5 Surgical Technique Note: For information on fixation principles using conven-tional and locked plating techniques, please refer to the LCP Locking Compression Plate Surgical Technique (DSEM/TRM/0115/0278). 1 Preoperative planning Complete the preoperative radiographic assessment and
LCP Locking Compression Plate - synthes.vo.llnwd.net
synthes.vo.llnwd.netSurgical Technique LCP Locking Compression Plate DePuy Synthes 7 LCP Methaphyseal 3.5 The LCP Metaphyseal Plates are indicated to fix extra- articular fractures in the metaphyseal area that can extend into the shaft area. The 3.5mm plates are indi-cated to fix fractures of the distal humerus and distal fi bula. Large Fragment plates (4.5/5.0)
For Medial High Tibial Osteotomies ... - synthes.vo.llnwd.net
synthes.vo.llnwd.netTomoFix Medial High Tibial Plate (MHT) Surgical Technique DePuy Synthes 1 Table of Contents Introduction Indications and Contraindications 4 General Remarks 5 Surgical Technique Open Wedge Surgical Technique 6 • Preparation and Approach 6
Inventory Control Form - synthes.vo.llnwd.net
synthes.vo.llnwd.netImplants (cont’d) Inventory Control Form J7889-C 2/12 2.7 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH 402.870 10 mm …
Universal and powerful battery ... - …
synthes.vo.llnwd.net4 DePuy Synthes Colibri II Instructions for Use Precautions: • To avoid injuries, the locking mechanism of the tool has to be activated before every manipulation and before placing the tool back down, i.e. the
LCKSMFRAG LCP ICF Final - synthes.vo.llnwd.net
synthes.vo.llnwd.netSmall Fragment Locking Compression Plate (LCP) System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. DSUS/TRM/1216/1260 4/17 3 One-Third Tubular LCP Plates, with collar Holes Length 241.331 3 33 mm
PFNA. Proximal Femoral Nail Antirotation.
synthes.vo.llnwd.net14 DePuy Synthes PFNA. Proximal Femoral Nail Antirotation Surgical Technique 1 Determine entry point In AP view, the PFNA entry point is on the tip or slightly lateral to the tip of the greater trochanter in the curved extension of the medullary cavity, as the ML angle of the PFNA is 6°.
Surgical Technique - synthes.vo.llnwd.net
synthes.vo.llnwd.netFor distal locking use 4.9 mm Titanium Locking Bolts or 5.0 mm Titanium Locking Screws For use only with the instruments and implants approved by the AO Foundation. 7/08 GP2026-B J8770A 170 mm and 235 mm Length s, for 10 mm, 11 mm, and 12 mm Cannulated Nail s Millimeters Illustrations shown actual size (0% Magnification) 135 º
3.5 mm LCP Low Bend Medial Distal Tibia Plates. …
synthes.vo.llnwd.net3.5 mm LCP Low Bend Medial Distal Tibia Plates The 3.5 mm LCP Low Bend Medial Distal Tibia Plate is part of the Synthes locking compression plate (LCP) system
Small Fragment Locking Compression Plate (LCP) …
synthes.vo.llnwd.net4 Synthes Small Fragment Locking Compression Plate (LCP) System Technique Guide AO Principles In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1 These principles, as applied to the Small Fragment LCP implants, are:
Zero-P and Zero-P chronOS. Zero ... - …
synthes.vo.llnwd.netSurgical Technique Zero-P and Zero-P chronOS DePuy Synthes 1 Table of Contents Introduction Zero-P and Zero-P chronOS. Zero profile anterior cervical interbody fusion (ACIF) device. 2 Zero-P pre-filled with chronOS 4
Operationstechnik - OSTEOSYNTESE.dk
www.osteosyntese.dkSynthes 3 Einführung 4 Operationstechnik 10 Produktinformationen 24 Zusätzliche Bemerkungen 27 Inhaltsverzeichnis Warnung! Diese Beschreibung reicht zur sofortigen Anwendung
2.4 mm and 3.0 mm Headless Compression Screws …
synthes.vo.llnwd.net2 Synthes 2.4 mm and 3.0 mm Headless Compression Screws Technique Guide The 2.4 mm Self-drilling, Self-tapping, Cannulated Headless Compression Screw T8 StarDrive recess 3.1 mm cortical thread (double thread*)
DHS/DCS System. Including LCP DHS - OSTEOSYNTESE.dk
www.osteosyntese.dkSynthes 1 Warning This description is not sufficient for immediate application of the instrumentation. Instruction by a surgeon experienced in handling this instrumentation is highly recommended.
Surgical Technique - OSTEOSYNTESE.dk
www.osteosyntese.dk6 Synthes PFNA Surgical Technique PFNA nail Excellent fit The anatomical design guarantees an opitmal fit in the femur. The nail design has been well proven in over 200 000 cases
Suprapatellar Instrumentation for Expert Tibial Nail.
synthes.vo.llnwd.net6 DePuy Synthes Suprapatellar Instrumentation for Expert Tibial Nail Surgical Technique Use the AO Preoperative Planner Template for the Expert Tibial Nail to estimate nail diameter and nail length. To esti-mate nail diameter, place the template on the AP or lateral x-ray of the uninjured tibia and measure the diameter of the
Occipital Cervical Fusion System TG - Testimonials
ljna.netOccipital Cervical Fusion System Midline plate construct The Synthes Occipital Cervical Fusion System is intended to provide stabilization as an adjunct to fusion of the occipito -
Similar queries
Synthes, Locking, Plate, The Synthes locking compression plate LCP, Surgical Technique - synthes.vo.llnwd.net, Surgical Technique, Tibial Nail, Synthes Expert, Nail, Expert TN. Tibial Nail, DePuy Synthes, LCP Locking Compression Plate, Locking Compression Plate, Synthes LCP Locking Compression Plate, Locking compression, Inventory Control Form - synthes.vo.llnwd.net, Inventory Control Form, Small Fragment Locking Compression Plate, PFNA, Synthes PFNA, Small Fragment Locking Compression Plate LCP, Synthes Small Fragment Locking Compression Plate LCP, System, Small Fragment, P chronOS. Zero profile anterior, Mm Headless Compression Screws, Cannulated, DHS/DCS System. Including LCP DHS, Expert Tibial Nail, Occipital Cervical Fusion System, The Synthes Occipital Cervical Fusion System