Search results with tag "Preventer"
GK Annular Blowout Preventer - Tasman Oil Tools
www.tasmanoiltools.comDOC TITLE: GK Annular Blowout Preventer DOC. No: Tas-RT-SBOP-001 REV: NA Page 1 of 2 GK Annular Blowout Preventer Applications & Benefits The GK annular blowout preventers field-tested and proven design has provided world class dependability and quality in surface applications.
ANNULAR BLOWOUT PREVENTER - axonep.com
www.axonep.comANNULAR BLOWOUT PREVENTER The Type 51 GK Annular Blowout Preventer is designed for safe well pressure control during drilling and workover operations. The simple design has been proven and accepted for reliable operation in all oil and gas areas in the …
MAINTENANCE & OPERATIONS MANUAL REGAN TYPE K …
toruspressurecontrol.comMAINTENANCE & OPERATIONS MANUAL for the REGAN TYPE K BLOWOUT PREVENTER September 27th 2013 Introduction: The Type K Annular Blowout Preventer was designed and first manufactured by Regan Forge & Engineering in San Pedro, California. Drawings date back to 1928, which makes it the earliest annular blowout preventer.The
Backflow Preventers and Protection of Water Supply: 2015 IPC
iccsafe.orgfor reduced pressure principle, double check, pressure vacuum, reduced pressure detector fire protection, and spill-resistant vacuum breaker backflow preventer assemblies and hose connection backflow preventers be performed in accordance with one of the following standards: ASSE 5013, ASSE 5015, ASSE 5020, ASSE5047, ASSE 5048,
STANDARD PLAN S FOR PUBLIC WORKS CONSTRUCTION
www.dpw.lacounty.gov511-3 backflow preventer assembly double check type 512-3 backflow preventer assembly reduced pressure type 51 &3 electrical pull box 5143 irrigation controller enclosure 515-3 pipe pinning 517-3 swing joint assembly 518-3 tree staking 519-3 tree well 520-4 tree planing 521-3 pressure regulator installation 522 root pruning
Florida Building Code 6 Edition (2017) Plumbing
www.broward.org312.10.2 Testing. Reduced pressure principle, double check, pressure vacuum breaker, reduced pressure detector fire protection, double check detector fire protection, and spill-resistant vacuum breaker backflow preventer assem-blies and hose connection backflow preventers shall be tested at the time of installation and immediately after
ASTHMA ACTION PLAN
d8z57tiamduo7.cloudfront.netASTHMA ACTION PLAN what to look out for ASTHMA MEDICINES PREVENTERS Your.preventer.medicine.reduces.inflammation,. swelling.and.mucus.in.the.airways.of.your.lungs..
SYSTEM 2000® FRONTIER - Energy Kinetics
energykinetics.com5 Principle of Operation - Energy Manager 18 15 Zone Manager Installation Instructions ... If antifreeze is used, a reduced pressure backflow preventer device shall be used. INSTALLER NOTE: ... backflow preventer, and all other devices must be piped to the nearest drain to avoid damage in the event the valve is actuated.
OPERATOR’S MANUAL - storage.googleapis.com
storage.googleapis.comOPERATOR’S MANUAL MSP 21 1/4"-2000 psi Annular Blowout Preventer ... GK blowout preventer. The hydraulic operating fluid may be clean, light petroleum hydraulic oil, or water with water soluble oil added. In cold climates, antifreeze should be added to prevent freezing.
READ ONLINE …
www.motorworksautorepair.comCheck out this Hydril GK 13-5/8" 5000 PSI Annular Blowout Preventer for sale by Pickett Oilfield. This Hydril GK Annular BOP is in good condition. Hydril Type Ram and Annular Blowout Preventers and 11"-5M and 13-5/8"-10M CPI type 91 door seals for Hydril Ram BOP's which have annealed square
2015 International Plumbing Code (amended) …
ldh.la.gov605.3.1 Dual check-valve-type backflow preventer. Dual check-valve backflow preventers installed on the water supply system shall comply with ASSE 1024 or CSA B64.6. These devices, which are commonly installed immediately downstream of water meters by water suppliers, are not approved backflow prevention devices
USA United Welding Inc - waterandoilwell.com
waterandoilwell.comDESCRIPTION: 13 5/8” 3M Hydril “GK” Annular Blowout . Preventer . SERIAL NUMBER: 6646 . QUANTITY: 1 piece . USA United Welding hereby certifies that the material on the above referenced Purchase Order was inspected and tested in accordance with API Specifications, USA United ...
Product Manual for Northstar HOT WATER/STEAM PRESSURE …
www.northerntool.comgallons per minute. The use of a backflow preventer on the water supply hose is recommended and may be required by local code. Any cleaning chemicals that are used must be specifically approved for use in pressure washers. The pump is powered by a gasoline-fueled engine. The spray water is heated (when desired) by a kerosene/fuel-
Backflow Prevention Products - Watts
media.wattswater.comBackflow is defined as the reverse flow of contaminated or undesirable substance into the potable water supply. Installing a backflow preventer can protect the water supply from this very serious type of situation. This product guide includes information on Watts’ complete line of backflow prevention devices. Code Requirements
BROADCAST SPREADER APPLICATION CHART 3854
cdn.gardensalive.comCrabgrass Preventer Plus Fertilizer 21-3-3 Lawn Fertilizer Plus 2% Iron 26-3-4 Sta-Green Bahia Weed & Feed 24-6-12 Winter Conditioner 8-8-25 3+3 Lawn Fertilizer 31-2-4 Fall Feed / Winterizer 22-3-14 St. Augustine Weed & Feed 27-3-8 Texas Fertilizer 15-5-10 Centipede Weed & Feed 15-0-15
Standard for the Inspection, Testing, and Maintenance of ...
www.nfpa.orgBackflow preventer Chapter 13 Check valves Chapter 13 Control valves Weekly (sealed) Chapter 13 Control valves Monthly (locked, supervised) Chapter 13 Deluge valve 10.2.2, Chapter 13 Detection systems NFPA 72 Detector check valves Chapter 13 Drainage Quarterly 10.2.87 Electric motor 10.2.98, Chapter 8
MASTER SPECIFICATIONS Division 21 FIRE SUPPRESSION
www.northwestern.eduvalves, standpipes, backflow preventers, gauges, hose connections and cabinets, and all other similar and required components. The University can provide a sample of the report when requested. F. Maps: Per the University requirements (and …
UFGS 22 00 00 Plumbing, General Purpose - WBDG | WBDG
www.wbdg.org2.5 BACKFLOW PREVENTERS 2.6 DRAINS 2.6.1 Floor and Shower Drains 2.6.1.1 Metallic Shower Pan Drains 2.6.1.2 Drains and Backwater Valves 2.6.2 Bathtub and Shower Faucets and Drain Fittings 2.6.3 Area Drains 2.6.4 Floor Sinks 2.6.5 Boiler Room Drains 2.6.6 Pit Drains 2.6.7 Sight Drains 2.6.8 Roof Drains and Expansion Joints
PRESSURE RELIEF VALVE ENGINEERING HANDBOOK
www.emerson.compressure of a reclosing pressure relief device. Backflow Preventer: a part or a feature of a pilot operated pressure relief valve used to prevent the valve from opening and flowing backwards when the pressure at the valve outlet is greater than the pressure at the valve inlet. II. TYPES OF DEVICES Pressure Relief Valve (PRV)
Outdoor Tankless Water Heater Installation and Operation ...
pdf.lowes.comsupply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. ontact the water supplier or local plumbing inspector on how to control thermal expansion. Type of installation • …
The Model 67, B67 & RB67 are automatic draining ...
www.woodfordmfg.comNIDEL® Model 50HA double check backflow preventer. ¾” inlet and outlet (specify type of inlet). Hardened stainless steel operating stem and one-piece valve plunger to control both flow and drain functions. Exterior finish to be Chrome Plated (options: Polished Brass or Rough Brass). Loose tee key to be furnished with each hydrant. Wall ...
Backflow Prevention and Cross-Connection Control
www.awwa.orgbackflow preventer Containment: Water supply protection from the property’s entire plumbing system. B. Location on public entity side of property line Figure 1-1 Examples of backflow prevention equipment locations Courtesy of Stuart F. Asay opyrit Aerican ater …
ABBREVIATIONS KEY TO SYMBOLS VALVES PLUMBING LEGEND
bidroom.netvalve and backflow preventer as shown or required by ahj. verify invert and slope of incoming sanitary sewer before trenching. 5. refer to riser diagrams and plumbing fixture schedule for all piping and pipe sizes not shown on plan. 6. sanitary and storm sewer piping shown is based on 1/4" per foot fall for all pipe smaller
TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY …
www.deq.ok.gov"Reduced pressure zone, backflow preventer" means a device designed to prevent backflow consisting of two spring loaded check valves with an intermediate reduced pressure zone that drains to the atmosphere by a relief valve, with a reduced pressure maintained in the intermediate zone by means of a pressure differential valve.
Backflow Prevention - Watts
media.wattswater.comThe FEBCO backflow preventer line includes top-quality, fully-tested Lead Free* versions of our standard backflow products. Standard Material Products (not Lead Free*) CONTAIN MORE THAN 0.25% LEAD. Effective January 4, 2014, it is illegal to use this product in any plumbing system providing water for human consumption,
Inspection, Testing, and Maintenance Cover Sheet
osfm.fire.ca.gov2.8 T Backflow Preventer Assemblies 13.6.2 2.9 T Small Hose Connections* w/PRV Hose Valves – Partial Flow Test 13.5.2.3 13.5.3.3 2.10 T PRV – Fire Sprinkler Systems 13.5.1.3 2.11 T Pressure Gauges - Calibration 5.3.2 2.12 T Small Hose Connections* 13.5.6.2.2 * Small hose connections are hose valves and optional hose supplied by the fire ...
2022-23 Statewide Flooding and Sea Level Rise Resilience Plan
protectingfloridatogether.govStormwater Backflow Preventer Installation Program $540,541 $200,000 $30,000 $70,000 $100,000 Martin County Martin Twin Rivers Park Shoreline Stabilization $1,724,000 $862,000 $65,000 $797,000 Martin County Martin Golden Gate Stormwater Treatment Area (STA) North Outfall Flood Mitigation $375,000 $180,000 $30,000 $150,000
Series 1156F, T156B and N256 - Watts
media.wattswater.comThe backflow preventer must be installed upstream of the regulator. 3. Prior to installing the regulator, flush out the supply pipe to clear it of chips, scale, dirt, etc. 4. Install the Watts regulator in the supply line to the boiler with the arrow on the valve body pointing in …
OPERATOR'S MANUAL FOR TOWNSEND 7-1/16 X 3M -7-1/16 …
northwellrentals.comannular bop townsend international sop's, inc. po box 14170 • 5381 w. 42nd street odessa, tx 79768 ... such as complete blowout preventer, accumulator. valve or manifolds, manufactured by other original equipment manufacturers, (0.e.m.). other than services rendered to …
Similar queries
GK Annular Blowout Preventer, GK annular blowout, Annular Blowout Preventer, MAINTENANCE & OPERATIONS MANUAL REGAN TYPE K, MAINTENANCE & OPERATIONS MANUAL, REGAN TYPE K BLOWOUT PREVENTER, Backflow, Reduced pressure, Pressure, Backflow Preventer, Reduced pressure principle, Preventer, SYSTEM 2000, Principle, A reduced pressure backflow preventer, OPERATOR’S MANUAL, GK blowout preventer, GK Annular, Annular Blowout, International Plumbing Code (amended), GK” Annular Blowout . Preventer, Backflow Prevention Products, Guide, Standard for the Inspection, Testing, and Maintenance, NFPA, BACKFLOW PREVENTERS, PRESSURE RELIEF VALVE ENGINEERING HANDBOOK, Tankless Water Heater, Protection, Backflow Prevention, Inspection, Watts, Annular, Blowout preventer