Example: stock market

Search results with tag "Flame spread"

ENVIRONMENTAL P D ECOTOUCH FLAME SPREAD …

ENVIRONMENTAL P D ECOTOUCH FLAME SPREAD

www.owenscorning.com

Page 2 of 3 EcoTouch® ®Flame Spread 25 FIBERGLAS™ Insulation with PureFiber Technology FSK and PSK Faced Fiberglass Insulation Batts According to ISO 14025 This declaration is an environmental product declaration (EPD) in accordance with ISO 14025.

  Spreads, Flame, Flame spread

ENVIRONMENTAL P D ECOTOUCH FLAME SPREAD …

ENVIRONMENTAL P D ECOTOUCH FLAME SPREAD

www.owenscorning.com

ENVIRONMENTAL PRODUCT DECLARATION ECOTOUCH® FLAME SPREAD 25 INSULATION Owens Corning EcoTouch® Insulation with PureFiber® Technology enhances comfort, energy savings and sustainability in new and existing structures.

  Owens, Corning, Insulation, Spreads, Flame, Flame spread, Flame spread 25 insulation owens corning

Fiberglas Pipe Insulation - Owens Corning

Fiberglas Pipe Insulation - Owens Corning

www.owenscorning.com

Flame Spread 25 Smoke Developed 50 1. Limited to single layer applications above 650°F (343°C), but not greater than 6" (152mm) thickness. 2. With heat up schedule. 3. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. Values are reported to the nearest 5 rating.

  Owens, Owens corning, Corning, Spreads, Flame, Flame spread

CommercialComplete Wall System - Owens Corning

CommercialComplete Wall System - Owens Corning

www.owenscorning.com

CommercialComplete® Wall System NFPA 285 Tested Wall Assemblies FOAMULAR® XPS Insulation, JointSealR® Foam Joint Tape, EcoTouch® Flame Spread 25, EcoTouch® Thermal Batt FIBERGLAS™ Insulation NFPA 285 Fire Tested Wall Assemblies Owens Corning’s CommercialComplete® Wall System has successfully passed the NFPA 285* fi re test in many variations giving architects options in …

  System, Walls, Owens, Owens corning, Corning, Spreads, Flame, Commercialcomplete, 174 wall system, Commercialcomplete wall system, Flame spread

NCDOI OSFM Evaluation Services

NCDOI OSFM Evaluation Services

www.ncdoi.com

File No. WP61-11 Material Combustibility Page 4 more than 0.125” thick, and the surfacing has a flame spread less than 50 when tested in accordance with ASTM E 84.

  Services, Evaluation, Spreads, Flame, Ncdoi, Ncdoi osfm evaluation services, Osfm, Flame spread

Fire Performance of Hardwood species - TerraMai

Fire Performance of Hardwood species - TerraMai

www.terramai.com

the actual specimens were not available. The plot suggests that the ASTM E 84 flame spread index is inversely related to the density of the wood.

  Performance, Species, Fire, Woods, Spreads, Flame, Hardwood, Flame spread, Fire performance of hardwood species

FLAME SPREAD/SMOKE DEVELOPMENT VALUES …

FLAME SPREAD/SMOKE DEVELOPMENT VALUES

www.nomacoinsulation.com

APPLICATION BULLETIN TS15-0909 Page 1 of 1 FLAME SPREAD/SMOKE DEVELOPMENT VALUES ASTM E84 ASTM E84 is the most common test method specified for determining the flame spread and smoke

  Development, Astm, Value, Smoke, Spreads, Flame, Flame spread, Flame spread smoke development values, Flame spread smoke development values astm

Flame Spread Index for Wood Products

Flame Spread Index for Wood Products

www.terramai.com

Flame Spread Index for Wood Products Fire Safety of Wood Products USDA, Forest Service Forest Products Laboratory One Gifford Pinchot Drive Madison, WI 53705-2398

  Spreads, Flame, Flame spread