Example: tourism industry

Search results with tag "40 psf live load"

TJI 110, 210, 230, 360, and 560 Joist Specifier's Guide

TJI 110, 210, 230, 360, and 560 Joist Specifier's Guide

parr.com

1 . Determine the appropriate live load deflection criteria . 2 . Identify the live and dead load condition . 3 . Select on-center spacing . 4 . Scan down the column until you meet or exceed the span of your application . 5 . Select TJI® joist and depth . Depth TJI® 40 PSF Live Load / 10 PSF Dead Load 40 PSF Live Load / 20 PSF Dead Load

  Live, Load, 40 psf live load, Live loads, Load 40 psf live load

TJI 110, 210, 230, 360, & 560 Joists Specifier's Guide

TJI 110, 210, 230, 360, & 560 Joists Specifier's Guide

www.hammondlumber.com

Long-term deflection under dead load, which includes the effect of creep, has not been considered. Bold italic spans reflect initial dead load deflection exceeding 0.33". Depth TJI® 40 PSF Live Load / 10 PSF Dead Load 40 PSF Live Load / 20 PSF Dead Load 12" o.c. 16" o.c. 19.2" o.c. 24" o.c. 12" o.c. 16" o.c. 19.2" o.c. 24" o.c. 9½"

  Live, Load, 40 psf live load, Load 40 psf live load

Required number of 16d common nails per connection, wood

Required number of 16d common nails per connection, wood

dpw.lacounty.gov

Dead load 10 psf / Live load 40 psf 3-8d (2-1/2" x 0.113") Roof Connection Fastener ROOF SPAN(FT.) Remarks RAFTER SLOPE 2x6 2x8 2x10 [Table R502.3.1(2)] (Dead load 10 psf; Panel continuous over two or more spans w/ long dimension perpendicular to supports; Applies to panels 24" or wider) [Table R503.2.1.1(1)] Joist size Spacing Allowable span ...

  Live, Load, 40 psf live load

TABLE 2 F LOOR JOISTS – 40 PSF LIVE LOAD , 10 PSF DEAD ...

TABLE 2 F LOOR JOISTS – 40 PSF LIVE LOAD , 10 PSF DEAD ...

www.southernpine.com

SOUTHERN PINE SPAN TABLES M ax imu sp ngv ef t d ch Inside to inside of bearings The spans in these tables were determined on the same basis as the code-recognized Span Tables for Joists & Rafters and Wood Structural Design Data, both published by the American Wood Council; concentrated loads and uplift loads caused by wind were not considered.

  Live, Load, 40 psf live load

MONTGOMERY COUNTY RESIDENTIAL TYPICAL DECK …

MONTGOMERY COUNTY RESIDENTIAL TYPICAL DECK …

www.montgomerycountymd.gov

Based on 40 psf live load Table 1. Montgomery County Residential Deck Details Page | 7 04/15/2021 Figure 6 5. DECK BEAM Maximum allowable spans for deck beams to be as per Table 2. Beam plies shall be fastened with two rows of 10d (3 in x 0.128 in) nails minimum at 16” o.c. along each edge. ...

  Live, Load, 40 psf live load

Similar queries