ESFR PENDENT TECHNICAL DATA SPRINKLER VK510 (K25.2)
www.vikinggroupinc.comFor Viking ESFR Pendent Sprinklers, refer to the Installation Standards (e.g., NFPA 25) and the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers.
SPRINKLER HEAD - NAFFCO FZCO
www.naffco.comthe Upright Sprinklers, and in the Pendent position for the Pendent Sprinkler, Pendent Recessed Sprinkler. Step 2 - Use only a non-hardening pipe joint compound or tape seal. Apply only to the male threads. Step 3 - Hand tighten the sprinkler into fitting. Step 4 - For Upright and Pendent Sprinklers, use a standard wrench.
QUICK RESPONSE TECHNICAL DATA DRY PENDENT …
www.vikinggroupinc.comFigure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers. QUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS For No. F3173 1.1.14 Rev 1.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 ...
Pocket Guide to Automatic Sprinklers
www.fmglobal.comUpright sprinklers are designed for installation on the top of sprinkler piping, with the deflector positioned above the orifice . This is the most common orientation for control-mode sprinklers . Pendent sprinklers are installed on the underside of piping, with the deflector located below the orifice . This orientation
Models F1 Series Standard Response Sprinklers
www.reliablesprinkler.comModel F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model W2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K-Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US Metric Upright Pendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position
QUICK RESPONSE TECHNICAL DATA DRY PENDENT …
www.vikingcorp.comQUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Quick Response Dry Pendent Sprinklers 3 ENT
ESFR PENDENT TECHNICAL DATA SPRINKLER VK500 (K14.0)
www.vikinggroupinc.comViking VK500 ESFR Pendent Sprinklers may be used in the protection of ordinary types of storage. However, they are primarily intended to protect the following types of stor-age, which tend to produce severe-challenge fires: palletized and solid pile storage and single, double, multiple row, and portable open rack storage (no open-top containers
Bulletin 110 January 2022 - Reliable Sprinkler
www.reliablesprinkler.comModel G Pendent Sprinklers Table C Bulletin 110 January 2022 Page 4 of 10 www.reliablesprinkler.com Notes: 1. 286°F (141°C) temperature rated sprinklers not approved for recessed installations. 2. FM Approval of Model G Recessed sprinkler for ordinary and extra hazard occupancies is limited to wet pipe systems only. 3.
standard response teChniCal data upright and pendent ...
www.vikingcorp.comstandard response upright and pendent sprinklers teChniCal data February 17, 2012 the Viking Corporation, 210 n industrial park drive, hastings Mi 49058
Tyco Fire & Building Products
firesecurity.grAlways refer to the Technical Data Sheet for complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. 7 STANDARD SPRAY TY-L Upright, Pendent & Recessed Pendent SPRINKLERS •Standard response •All hazards •Solder type •Discharges a hemispherical ...
Similar queries
Pendent, Pendent SPRINKLERS, Sprinklers, Sprinkler, Pendent Sprinkler, QUICK RESPONSE TECHNICAL DATA DRY PENDENT, Recessed, QUICK RESPONSE TECHNICAL DATA DRY PENDENT SPRINKLERS, Quick Response, PENDENT TECHNICAL DATA, Standard response teChniCal data upright and pendent, Upright, Tyco Fire & Building Products