Search results with tag "Gypsum"
Moisture Resistant Gypsum Board - CertainTeed
www.certainteed.com• CAN/CSA-A82.31 Gypsum Board Application • ASTM C 840 Application and Finishing of Gypsum Board • GA-216 Application and Finishing of Gypsum Board • National Building Code of Canada (NBCC) Fire resistance rated assemblies using any ProRoc® Type X products must be constructed in accordance with the details as shown in the latest ...
UL U356 Summary One-Hour Fire-Resistance Rated, Limited ...
www.drjcertification.orgNov 08, 2012 · Gypsum Board* — (As an alternate to Item 2, not shown) - For Use with Item 5A only - 5/8 in. thick 4 ft. wide gypsum panels applied horizontally and attached to studs and bearing plates with 1-1/4 in. long Type W coarse thread gypsum panel steel screws spaced a max 8 in. OC, with last screws 1 in.
2-Hour Fire Endurance Assembly for MPCWT Structural Floor ...
sbcindustry.comOct 02, 2017 · Type C gypsum wallboard is attached to the furring or resilient channels. The end joints of each gypsum wallboard sheet shall be centered on the resilient or furring channel. Ceiling Membrane Layer 2 Material 5/8 Type C gypsum wallboard Attached to Furring/resilient channel Fastener type 1-1/ 4 Type S bugle-head screw Spacing 6 maximum
ANSI/ASHRAE/IES Standard 90.1-2010 Envelope
neep.orgExterior gypsum sheathing or interior gypsum board ½ in. Cement board ½ in. Built up roofing membrane Modified bituminous roof membrane Fully adhered single-ply roof membrane A Portland cement / sand parge, stucco, or gypsum plaster ½ in. Cast-in-place and precast concrete sealed w/grout or paint Sheet metal
The Gypsum Association FIRE RESISTANCE DESIGN …
www2.et.byu.eduor 5/8 inch type X gypsum board is applied to the ceiling. The addition-al layer of gypsum board shall be applied as described for the face layer of the tested system except that the fastener length shall be in-creased by not less than the thick-ness of the additional layer of gyp-sum board. The detailed descriptions for the
EEM-00259 Permeability of Common Building Material to ...
www.builditsolar.comIf a material has a perm rating of 1.0, we know that in 1 hour, when the vapor pressure difference be- ... Plaster on plain gypsum lath, with studs 0.75 20 Gypsum wall board, plain 0.375 50 ... Polyester, glass fiber reinforced sheet 0.048 0.05 THERMAL INSULATIONS Air still 120 Cellular glass 0 Mineral wool, unprotected 116 ...
Fire Safety Information 5/8' Type X Gypsum Wallboard (English)
www.usg.comall gypsum wallboard manufacturers in the Unit ed States subscribe to an independent third party certification and labeling service such as UL to ensure product consistency and quality. ASTM E 119 was initially published in 1918 (as ASTM C 19) and has been used
Standard Specification for Application of Portland Cement ...
www.floridabuilding.orgGypsum and Related Building Materials and Systems and is the direct responsibility of Subcommittee C11.03 on Specifications for the Application of Gypsum and Other Products in Assemblies. basic cementitious material add Current edition approved Oct. 1, 2011. Published November 2011. Originally approved in 1981.
Technical Guide: DensShield® Tile Backer
pdf.lowes.comGeorgia-Pacific Gypsum and Sustainability Georgia-Pacific Gypsum’s definition of sustainability is meeting the needs of society today without jeopardizing our ability to do so in the future. We are committed to using resources efficiently to provide innovative products …
EcoBatt Insulation - Cloudinary
res.cloudinary.com8" thick Type X gypsum board, single layer both sides 40 Wood frame, 2 x 4 (3½" – 4" Batt), 24" O.C., 5 ⁄ 8 " thick Type X gypsum board, single layer both sides, resilient channel 52
USG DUROCK BRAND CEMENT BOARD SYSTEMS
www.usg.com• 5/8" USG Sheetrock® Brand Firecode® gypsum panels – RC-1 channels or equivalent – Joints finished – Steel roof deck – Steel truss 48" o.c. • Roof covering and roof insulation over 1/2" USG Durock® Brand cement board or 1/2" USG Sheetrock® Brand gypsum panels UL …
WIND & SEISMIC - AWC
www.awc.orgWallboard or Gypsum Sheathing Board) ..... 32 4.3C Nominal Unit Shear Capacities for Wood-Frame Shear Walls (Gypsum and Portland Cement Plaster) ..... 33 4.3D Nominal Unit Shear Capacities for Wood-Frame Shear Walls (Lumber Shear Walls) ... 34 4.4.1 Nominal Uplift Capacity of 7/16" Minimum
ICC PEI LLC
p-e-i.comReport Owner United States Gypsum Company usg4you@usg.com For Evaluation Report Questions USG Support: 800.USG4YOU 2. Steel Studs Cut the C-H Studs 3/8-in to 1/2-in shorter than the floor-to-ceiling height. Install C-H Studs interlocked between the SHEETROCK® Brand Gypsum Liner Panels with the liner panels securely engaged. The C-H Studs must ...
Technical Guide: DensArmor Plus® High-Performance Interior ...
www.buildgp.comof Gypsum Panel Products” and ASTM C840 “Standard Specifi cation for Application and Finishing of Gypsum Board for Non-Fire Rated Construction.” For best results, abut DensArmor Plus panels against regular paper-faced drywall only at inside or outside
Fire Resistance Rated Truss Assemblies
sbcindustry.comBase layer 5/8" Type X gypsum wallboard applied at right angles to joist or truss 24" o.c. with 1-1/4" Type S or Type W drywall screws 24" o.c. Face layer 5/8" Type X gypsum wallboard or veneer base applied at right angles to joist or truss through base layer with 1-7/8" Type S
Technical Specifications for Construction and Management ...
www.dni.govMar 13, 2020 · 1.2 04/23/12 9-10 Changed “Type X Gypsum” to “wallboard” to remove the standard of fire resistant gypsum and permit use of other wallboard types. PTSEWG 1.2 04/23/12 9-10 Changed references to wall design drawings to “suggested” wall types to enable variety of wall construction techniques to meet the security standards.
National Gypsum Purple Book Fire Rated Assemblies in ...
www.buildsite.comThe PURPLE Book® II is the second edition of National Gypsum Company’s Fire-Rated Assemblies in Commercial Construction. Originally published in 2013, The PURPLE Book® has proven to be a trusted resource for architects, contractors and inspectors
Sound and Fire-Rated SAFB Assemblies - Construction
sweets.construction.com2-hr. shaft wall partition—1" THERMAFIBER SAFB in stud cavity—2 layers 1/2" gypsum wallboard Type C core, one side—1" gypsum wallboard liner panels set between 25 ga.steel C-H studs 24" o.c.—joints fin—UL Des U415 or U438—BBN-750706 60 STC*** 2-hr. area separation wall partition—3" THERMAFIBER
USG Solutions USG SHEETROCK BRAND PLUS 3 JOINT …
www.usg.comPRODUCT DATA Type: A ready-mix drying type joint compound. Use: Hand or mechanical tool application. Coverage: Approximately 9.4 gal./1,000 sq. ft. (38.3 L/100 sq. m) of gypsum panels. Compliance with Standards: Meets ASTM C475, Standard Specification for Joint Compound and Joint Tape for Finishing Gypsum Board.
SAFETY DATA SHEET - USG
www.usg.comGypsum dust has an irritant action on mucous membranes of the upper respiratory tract and eyes (1). Skin contact Under normal conditions of intended use, this material does not pose a skin hazard. Gypsum was not found to be a skin irritant (2). Eye contact Mechanical processing may generate dust. Direct contact with eyes may cause temporary ...
Fire-Resistant Assemblies Brochure (English) - SA100
www.usg.comFireproofing protecting columns and beams with gypsum base and veneer finishes, mineral fireproofing, and gypsum drywall. F Exterior Walls56-59 Steel-framed, including loadbearing and non-loadbearing; and wood-framed, including loadbearing. Includes exterior curtain wall assemblies. Pages
USG SHEETROCK BRAND ECOSMART PANELS FIRECODE X
www.usg.com8 USG.4OU 8 (874-498) usg.com Manufactured by United States Gypsum Company 55 West Adams Street Chicago, IL 1 WB2859-USA-ENG/rev. 5-21 221 USG Corporation and/or
USG Fire-Resistant Assemblies Catalog (English) - SA100
www.usg.comUSG Gypsum Construction Handbook Industry Resources Underwriter Laboratories, Inc. Fire Resistance Directory, Volume One. 5 USG Fire-Resistant Assemblies Selector Overview The sections listed below correspond to the different types …
UNITED STATES COURT OF APPEALS FOR VETERANS …
www.uscourts.cavc.govGilbert v. Derwinski, 1 Vet.App. 49, 53 (1990), (quoting United States v. U.S. Gypsum Co., 333 U.S. 364 (1948)). "[T]his Court is not permitted to substitute its judgment for that of the [Board] on issues of material fact; if there is a plausible basis in the record
Plaster Systems Brochure (English) - SA920
www.usg.comor fiber-reinforced gypsum panel. 4 USG Plaster Systems Overview. 5 USG Plaster Systems Conventional Three-Coat Plaster Systems Conventional plaster systems are the best choice to attain a uniform, monolithic, blemish-free, smooth surface with good to excellent wear resistance based on the type of finish plaster. These systems make intricate ...
Ceiling USG SHEETROCK BRAND LAY-IN GYPSUM CEILING …
www.usg.comCGC: contact Sales Representative TECNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com Edge Panel Size Fire Rating 2 Item No. NRC4 CAC Min. LR3 Color Abuse Resistant Grid Options VOC Emissions Recycled Content1 Panel Cost …
BXUV.U497 Fire Resistance Ratings - ANSI/UL 263 Design ...
www.scafco.comJul 01, 2010 · Gypsum Board* — 1/2 in. thick, 4 ft wide wallboard applied vertically in two layers. Inner or base layer attached to studs Inner or base layer attached to studs with 1 in. long Type S self-drilling, self-tapping bugle head steel screws spaced 24 …
REQUIREMENTS FOR CONSTRUCTION OF A DETACHED …
www.stpaul.govFiber-reinforced concrete is allowed. 6. Anchor bolts shall be a minimum 1/2" diameter, maximum 1' from the corner with a minimum of 2 anchor bolts ... On an attached garage a fire wall between the house and garage shall not be less than ½" gypsum wallboard applied on the garage side. Doors opening into the dwelling shall not be less than ...
Schluter -Shower System Installation Handbook 2020
pdf.lowes.comflange. In addition, KERDI is installed over the solid backing (e.g., gypsum board, cement backerboard, etc.) on walls, creating a fully waterproof and vapor-tight enclosure. The resulting assembly provides superior moisture management as it does not permit moisture to penetrate into the mortar bed or solid backing, allowing the
Glossary of Architectural Terms
www.strombergarchitectural.comGFRC (glass fiber reinforced concrete,) GRG (glass fiber reinforced gypsum,) plaster, bronze, granite or marble. Abrasive Finish A flat and grainy surface texture. In cast stone, GFRC (glass fiber reinforced concrete) or architectural precast concrete this is accomplished by acid washing or sand blasting. In GFRP (architectural fiberglass) or GFRG
Fire Rated Wood Floor and Wall Assemblies
library.um.edu.moGypsum Association's Fire Resistance Design Manual. The American Forest & Paper Association (AF&PA) and its members have tested a number of wood-frame fire-rated assemblies. Descriptions of these successfully tested assemblies are provided in Table 1 for one-hour rated wall assemblies, Table 2 for two-hour rated wall assemblies, Table 3 for one ...
Seismic Construction Handbook - Sound Concepts
www.soundconceptscan.com• Screw or nail attached gypsum board ceilings of one level, surrounded by walls that connect to the building structure Introduction. CIS CISCA | Seismic Construction Handbook 3 • Ceilings less than 144 square feet (13.4 m2) that are surrounded by …
Installation Guide and Detailing Options for Compliance ...
www.eldoradostone.com• Gypsum Wall Board • Plywood • 3OSB • Fiber Board Optional6 Any approved lath7 Corrosion resistant; minimum penetration 3/ 4 in. (19 mm) into wood framing member or / 8 in. (10 mm) into steel framing member Type N or S mortar complying with ASTM C270 or ASTM C1714; minimum nominal thickness 1/ 2 in. (13 mm) See Table 2 • Cement Board ...
Technical Services: 888-437-3244 Sales ... - ClarkDietrich
www.itools.clarkdietrich.com• The composite limiting heights provided in the tables are based on a single layer of 5/8" Type X gypsum board from the following manufacturers: American, CertainTeed, Georgia Pacific, Continental, National, PABCO, and USG.
USG Fire Resistant Assemblies Head of Wall Details
www.usgdesignstudio.comrestraining angle lined with gypsum board matching partition below fasteners to be set flush on drywall side perpendicular to deck flutes restraining angle mineral wool batt insulation ... head of wall partition details fire resistant assemblies head of wall details usg j2132 rev 0 issued 10/19/2015. scale: 3" = 1' - 0" 2 hr head of wall ul hw ...
Building Materials Property Table - Energy
www1.eere.energy.govgypsum board painted with latex paint a value of ~3 perms (dry cup), BSC has measured samples with dry cup measurements of roughly 8-10 perms (see Ueno et al. 2007) More information : Exterior acrylic paint ; 5.5 : Semi-gloss vinyl acrylic enamel; 6.6 : 6.6 : Exterior oil-based paint (3 coats) 0.3-1.0 ; Oil paint (1 coat + primer) 1.6 - 3 ...
Design No. U340
pac-intl.comcompound. As an alternate, nom 3/32 in. thick gypsum veneer plaster may be applied to entire surface of Classified veneer baseboard. Joints reinforced. 4. Batts and Blankets* — (Optional) Required when Item 5E is used. Any thickness glass or …
9HUVD%RQG 3URIHVVLRQDO7KLQ 6HW0RUWDU 7'6 …
images.thdstatic.comMar 27, 2018 · Gypsum wallboard (interior dry areas) Existing ceramic tile (scarified) Fully-bonded sheet vinyl flooring (scarified) ... additives Limitations to the Product Do not bond directly to hardwood, Luan plywood, particle board, ... USE CHEMICAL-RESISTANT GLOVES, such as nitrile, when handling product.
Commercial Facility Guide Specification - Sherwin-Williams
images.sherwin-williams.comGuide Specification This Painting Schedule is furnished as a guide ... Gypsum Board — Ceilings and Soffits Wood — Painted Doors, Frames, Trim and Chair Rails ... For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority. Removal must be done in accordance with EPA ...
The Posi-Joist Technical Handbook
irp-cdn.multiscreensite.comThe responsibility for specification of the ... insulation, 15mm gypsum wallboard ... Deflection limits are given in the National Annex to EC5. For joists with plasterboard ceilings a limit of span/250 is applied to the final deflection (sum of instantaneous and creep deflections).
Shear wall Design in Residential Construction: A ...
www.phrc.psu.eduGypsum Board Particleboard Sheathing Portland Cement Plaster Hardboard Panel Siding Alternate Braced Wall Because of the relative complexity of choosing and analyzing braced-wall sections per the IRC, the Engineered Wood Association (APA) published A Guide to the IRC Wood Wall Bracing Provisions (APA 2009).
Installation, Operation and Maintenance Manual
content.greenheck.com• Gypsum wall board must be fastened 12 in. (305mm) on center (O.C.) to all stud and runner flanges surrounding opening. • Prepare opening between studs and sleeve assembly as shown below (see Figure 3 & 4). • All construction and fasteners must meet the requirements of the appropriate wall design (See UL Fire Resistance
GYPSUM PANEL PRODUCTS TYPES, USES, SIZES, AND …
www.gypsum.orgamerican gypsum national gypsum company bpb america inc. pabco gypsum bpb canada inc. a division of pabco building products, llc cgc inc. temple-inland forest products corp. g-p gypsum corporation united states gypsum company lafarge north america inc. gypsum association 6525 belcrest road, ste 480 hyattsville, md 20782 301-277-8686 fax: 301 ...
Gypsum Wallboard Column Fireproofing - BuildSite
www.buildsite.comInner two layers furred from column by 1 5/8" (41.3 mm) steel studs at column corners. Outer two layers attached to 2" x 2" (51 mm x 51 mm) sheet metal angles which are applied at corners over first two layers of board. COLUMN (14WF–228) 9 2 hr. UL X520 One layer of 1/2" (12.7 mm) Fire-Shield C Gypsum Wallboard furred from column by
GYPSUM BOARD COMPARISON CHART - BuildSite
www.buildsite.comComparison Chart - 1Continental Building Products - Gypsum Board Comparison Chart, Comparison Chart Created Date: 2/29/2016 2:21:27 PM ...
Gypsum Board Systems Manual - BuildSite
www.buildsite.comIntroduction General Fire Resistance ... unexposed surface temperature may not rise more than an average of 139˚C (250˚F) above the initial ... 181˚C (325˚F). Surface Burning Characteristics Flame spread ratings are intended as a guide in the selection and use …
Similar queries
Gypsum Board, CertainTeed, National, Gypsum, ASHRAE, Gyp-sum board, Material, Plaster, Glass fiber reinforced, Glass, Unit ed States, Standard Specification for Application of Portland, DensShield, WIND & SEISMIC, Report, United States Gypsum, For Evaluation Report Questions USG, Guide, Construction, Gypsum wallboard, National Gypsum, National Gypsum Company, In Commercial Construction, Fire, Wall, USG Solutions USG SHEETROCK BRAND PLUS, DATA, SAFETY DATA SHEET, Fire-Resistant Assemblies Brochure, Steel, Loadbearing, USG SHEETROCK BRAND ECOSMART PANELS, USG Fire-Resistant Assemblies Catalog, USG Gypsum Construction Handbook, USG Fire-Resistant Assemblies, UNITED STATES COURT OF APPEALS FOR VETERANS, United States, Brochure (English) - SA920, Reinforced gypsum, BRAND LAY-IN GYPSUM CEILING, Representative, Reinforced, Schluter, Glossary of Architectural Terms, Glass fiber reinforced gypsum, Fire Rated, Rated, Hour rated wall, Construction Handbook, Installation Guide and Detailing Options for Compliance, American, Fire resistant assemblies, Materials, Energy, Additives, CHEMICAL, Guide Specification, Sherwin-Williams, Specification, Gypsum wall, GYPSUM PANEL PRODUCTS TYPES, USES, SIZES, AND, Gypsum national gypsum, Gypsum Wallboard Column Fireproofing, Column, Gypsum Board Comparison Chart, Building, Gypsum Board Systems Manual, Introduction, Surface