Search results with tag "Unrestrained assembly rating"
Table 1 Fire Resistance Ratings - Siplast
www.siplast.comAn Unrestrained Assembly Rating of 1 hr. is achieved for 1 5/16-inch, 24-gauge steel deck with clear spans £ 90-inch. 10. W6 x 16, W8 x 10, W8 x 18, 12J4, 12K5, 14K3. 11. For 2 hour Restrained Assembly Rating: 96" o.c. support spacing for 22-gauge 1 1/2-inch or 3-inch fluted steel deck.
Design No. L521 - PAC International
pac-intl.comUnrestrained Assembly Rating — 1 Hr Finish Rating — 25 Min (See Items 5 and 5A), 20 Min (See Items 6H and 7A) This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For …
Unrestrained Assembly Rating - 1 Hr. Finish Rating - 22 ...
pac-intl.comUnrestrained Assembly Rating - 1 Hr. Finish Rating - 22 Min. This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7