Vertiv Geist Rack PDUs

Vertiv Geist Rack PDUs

www.vertiv.com

VP9571A Basic Standard H 208V 30A 4.9kW L6-30P (12) C13 45°C N/A VP7541 Basic Standard V 208V 30A 4.9kW L6-30P (20) C13 / (4) C19 45°C N/A VP8830 Monitored Unit Level V 120V 20A 1.9kW L5-20P (24) 5-20R 60°C YES VP8832 Monitored Unit Level V 120V 30A 2.8kW L5-30P (24) 5-20R 60°C YES

  Rack, 120v, 208v, Pdus, Gesti, Vertiv geist rack pdus, Vertiv

DySC Dynamic Voltage Sag Corrector Specifications

DySC Dynamic Voltage Sag Corrector Specifications

literature.rockwellautomation.com

6 A 120V L-N Standard 1608N-006A120V2S L-N Extended 1608N-006A120V2E MiniDySC Single Phase Voltage Sag Corrector - Panel Mount Rated Current [A] Line Voltage [V] Wiring Category Runtime Cat. No. 12 A 120V L-N Standard 1608N-012A120V2S L-N Standard 1608N-012A120V2S-R 208V L-L Standard 1608N-012A208V1S

  120v, 208v

Input voltage range 208V, 3-Phase AC Fast, Compact and ...

Input voltage range 208V, 3-Phase AC Fast, Compact and ...

www.evrus.net

PARAMETERS PERFORMANCE Input voltage range 208V, 3-Phase AC Rated input voltage range 60Hz Max input current ≤ 58 Ampere Max power factor ≥0.99

  Phases, Ranges, Input, Voltage, 208v, 3 phase, Input voltage range 208v

120V/208V - Power Pros, Inc. - Eaton Powerware UPS

120V/208V - Power Pros, Inc. - Eaton Powerware UPS

www.powerprosinc.com

120V/208V. Designed for Windows Server 2003 ... APC Smart-UPS sine-wave output provides assurance of compatibility ... Under this unique policy, the total recovery limit of a Smart-UPS product’s Lifetime Equipment Pro-tection Policy is doubled. APC will then repair or replace properly con-

  120v, 208v, 120v 208v

Three Phase Inverters for the 120/208V Grid - SolarEdge

Three Phase Inverters for the 120/208V Grid - SolarEdge

www.solaredge.com

Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC part15 class A INSTALLATION SPECIFICATIONS AC output conduit size /AWG range ¾” or 1” / 6 - 10 AWG DC input conduit size / AWG range ¾” or 1” / 6 - 12 AWG

  Phases, Three, Inverter, 208v, Ul1741, Three phase inverters for the 120 208v

Sizing Transformers - Dongan

Sizing Transformers - Dongan

dongan.com

kva 200v 208v 240v 380v 415v 480v 575v 600v 3 8.6 8.3 7.2 4.5 4.1 3.6 3.0 2.8 6 17.3 16.6 14.4 9.1 8.3 7.2 6.0 5.7 9 26.0 25.0 21.6 13.6 12.5 10.8 9.0 8.6 15 43.3 41.6 36.1 22.8 20.8 18.0 15.0 14.4 25 72 69 60 38.0 34.8 30.1 25.1 24.0 30 86 83 72 45.6 41.7 36.1 30.1 28.9 45 130 125 108 68 62 54 45.2 43.3 75 216 208 180 114 104 90 75 72 112.5 ...

  208v

LV (600V) Dry-Type Transformers - Federal Pacific

LV (600V) Dry-Type Transformers - Federal Pacific

federalpacific.com

N 208V - 120/240V S20LH21 15, 25, 37, 50, 75, 100, 167 Y N 240x480V - 120/240V S2XLH21 Y 600V - 120/240V S60SH21 CU 150°C N 240x480V - 120/240V S2XGH21 Y S2XCH21 Single Phase Encapsulated Buck-Boost Transformers Part Number = Family [-KVA] Conductor Temp Rise (Celsius) Electrostatic Shield Primary/Secondary Family KVA Available Taps Available ...

  208v

HIGH POWER WALL CONNECTOR - Tesla, Inc.

HIGH POWER WALL CONNECTOR - Tesla, Inc.

www.tesla.com

120V ABOVE GROUND (common in North America) 230V ABOVE GROUND (common in Europe, Asia, and Australia) Voltage and Wiring 240V AC single-phase: L1, L2, and safety ground 208V AC 3-phase, wye-connected: Any 2 phases, and safety ground. 240V AC 3-phase, delta-connected: With center tap on one leg, use only the two phases on either side of the ...

  120v, 208v

REPLACEMENT PARTS CATALOG

REPLACEMENT PARTS CATALOG

www.heatersplus.com

BASEBOARDS. 3. HBB&CBD. Key No. Description Part Number. 1 Element(HBB): 120V 208V 240V 277V. 28” 1802-2068-000 1802-2068-005 1802-2068-011 1802-2068-017

  Catalog, Part, Replacement, 120v, 208v, Replacement parts catalog, 120v 208v

Wiring Diagrams - AutomationDirect

Wiring Diagrams - AutomationDirect

cdn.automationdirect.com

208V/200V 25V/24V/23V 120V/115V/110V High Voltage (HV) Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) Between Terminals Connect To Clips To 480 460 440 None 2, 6 Unfused 240 230 220 None 2, 4 Unfused 208 200 None 2, 3 …

  120v, 208v

Voltage Drop - Adams Electric

Voltage Drop - Adams Electric

www.adamselectric.coop

(120V x 5%) or no more than 6V less than the source. So, the operating voltage should be no less than (120V – 6V) or 114V. ... 100 ampere load rated 208V is wired to the panelboard with 80 ft lengths of #1 AWG THHN aluminum. What is the approximate voltage drop of the feeder circuit conductors?

  120v, 208v

パワートランス (静電シールド、磁気シールド付)

パワートランス (静電シールド、磁気シールド付)

hashimoto-trans.co.jp

pt-400b 100v 20v-0-280v-320v-360v-720ma ac (450ma dc;ブリッジ整流) ... 使用時 ②コンデンサーインプット 170ma px25a, da30, 300b