Seattle SDCI - Seattle Building Code, Chapter 10, Means of ...
www.seattle.gov1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by a building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the minimum width or required capacity of a means of egress component except projections permitted by this ...
Presentation: NYC Construction Code - Chapter 10 Means of ...
www.mzarchitects.comMeans of Egress Continuity Section 1003.6: “The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter.
780 CMR 10.00 MEANS OF EGRESS - Mass.gov
www.mass.govMEANS OF EGRESS 780 CMR 1001.0 ADMINISTRATION 1001.1 General. Buildings or portions thereof shall be provided with a means of egress system as required by 780 CMR 10.00. The provisions of 780 CMR 10.00 shall control the design, construction and arrangement of means of egress components re quired to provide a n approve d means
CHAPTER 10 MEANS OF EGRESS - DSPS Home
dsps.wi.govvided with a means of egress system as required by this chapter. The provisions of this chapter shall control the design, con struction and arrangement of means of egress co1nponents re quired to provide an approved means of egress from structures and portions thereof. 1001.2 Minimnm reqnirements. It shall be unlawful to alter a
CHAPTER 10 MEANS OF EGRESS - Home | ICC Store
ecodes.bizpath of egress travel from an occupied room, area or space where the path of egress enters an intervening room, corridor, unenclosed exit access stair or unenclosed exit access ramp. EXIT DISCHARGE. That portion of a means of egress sys-tem between the termination of an exit and a public way. EXIT DISCHARGE, LEVEL OF. The story at the point at
CHAPTER 10 MEANS OF EGRESS - iccsafe.org
www3.iccsafe.orgThe means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than the total occupant load served by the means of egress multiplied by 0.3 inches (7.62 mm) per occupant for stairways and by 0.2 inches (5.08 mm) per occupant for other egress components.
Life Safety - Means of Egress/Exits NFPA 101
www.secura.netEgress width In determining the egress width for a doorway for purposes of calculating capacity, only the clear width of the doorway when the door is in the full open position should be measured. Clear width is the unobstructed width of the door opening. No door opening in the means of egress should be less than 32 inches clear width opening.
ARTICLE 7. MEANS OF EGRESS Sub-Article 1. General Egress ...
www1.nyc.govsuch means of egress, consisting of interior stairways, fire towers, horizontal exits, ramps, escalators or party wall balconies, including the necessary hallways and doorways, as may be otherwise required. 2. Structures exceeding three stories above any basement in height, occupied as dwellings by one or two families, shall be provided with ...
CHAPTER 10 MEANS OF EGRESS - iccsafe.org
www3.iccsafe.org1. In Group R-2 and R-3 occupancies, one means of egress is permitted within and from individual dwelling units with a maximum occupant load of 20 where the dwelling unit is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. 2. Care suites in Group I-2 occupancies complying with Section 407 ...