1-Piece Aspheric IOL - Precision Lens

TECNIS 1-Piece Aspheric IOL.. Hydrophobic Acrylic mm OVERALL. DIAMETER. TECNIS IOL WAVEFRONT-DESIGNED. Aspheric SURFACE. Anterior HAPTICS OFFSET FOR. Side 3 POINTS OF FIXATION FROSTED, CONTINUOUS 360 . POSTERIOR SQUARE EDGE. Posterior Side mm OPTIC. DIAMETER. Model: ZCB00. DESCRIPTION. OPTIC CHARACTERISTICS. Powers: + D to + D in diopter increments Diameter: mm Shape: Biconvex, anterior Aspheric surface, square optic edge Material: UV-blocking hydrophobic acrylic Refractive Index: Edge Design: ProTEC frosted, continuous 360 posterior square edge OPTICAL BIOMETRY*.

Caution: Federal law restricts this device to sale by or on the order of a physician. Important Safety Information for TECNIS® Monofocal IOL Indications: TECNIS® 1-Piece IOLs are indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag.

Tags:

  Pieces, Lens, 1 piece aspheric iol, Aspheric

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1-Piece Aspheric IOL - Precision Lens

1 TECNIS 1-Piece Aspheric IOL.. Hydrophobic Acrylic mm OVERALL. DIAMETER. TECNIS IOL WAVEFRONT-DESIGNED. Aspheric SURFACE. Anterior HAPTICS OFFSET FOR. Side 3 POINTS OF FIXATION FROSTED, CONTINUOUS 360 . POSTERIOR SQUARE EDGE. Posterior Side mm OPTIC. DIAMETER. Model: ZCB00. DESCRIPTION. OPTIC CHARACTERISTICS. Powers: + D to + D in diopter increments Diameter: mm Shape: Biconvex, anterior Aspheric surface, square optic edge Material: UV-blocking hydrophobic acrylic Refractive Index: Edge Design: ProTEC frosted, continuous 360 posterior square edge OPTICAL BIOMETRY*.

2 A-constant: ULTRASOUND BIOMETRY . A-constant: Theoretical AC Depth: mm Surgeon Factor: 1. mm HAPTIC CHARACTERISTICS. Overall Length: mm Style: C. Material: UV-blocking hydrophobic acrylic Design: Haptics offset from optic RECOMMENDED INSERTION INSTRUMENTS MODEL. UNFOLDER Platinum 1 Series Screw-Style Inserter . DK7796. UNFOLDER Platinum 1 Series Cartridge 1 MTEC30. ONE SERIES Ultra Syringe-Style Inserter DK7786. ONE SERIES Ultra Screw-Style Inserter DK7791. ONE SERIES Ultra Cartridge 1 VIPR30. *Derived from clinical evaluation results of the TECNIS 1-Piece platform.

3 Value theoretically derived for a typical D lens . AMO recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results. To learn more and to view important safety information, please MICRO- IMPLANTATION. visit Or call 1-877-AMO-4-LIFE. CATARACT. SUITE. Caution: Federal law restricts this device to sale by or on the order of a physician. Important Safety Information for TECNIS Monofocal IOL. Indications: TECNIS 1-Piece IOLs are indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction.

4 These devices are intended to be placed in the capsular bag. Warnings: Physicians considering lens implantation under any of the conditions described in the Directions for Use labeling should weigh the potential risk/benefit ratio prior to implanting a lens . Precautions: Do not resterilize or autoclave. Use only sterile irrigating solutions such as balanced salt solution or sterile normal saline. Do not store in direct sunlight or in temperatures over 45 C. Adverse Events: The most frequently reported adverse event that occurred during the clinical trial of the 1-Piece lens was macular edema, which occurred at a rate of Other reported reactions, occurring in less than 1% of patients, were secondary surgical intervention (pars plana vitrectomy with membrane peel) and lens exchange (due to torn lens haptic).

5 Attention: Reference the Directions for Use labeling for a complete listing of indications, warnings and precautions. 1. Calculated based on Holladay I formula (Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24). TECNIS, ProTEC, UNFOLDER and ONE SERIES are trademarks owned by or licensed to Abbott Laboratories, its subsidiaries or affiliates. 2012 Abbott Medical Optics Inc. Reorder: TEC06-13.