15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 1 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric PolycarbonateImpact Resistant Bushing Guard withOpen Top is available In-Air Insulationeliminates leaking orcontamination ofinsulating medium forlong trouble-freeoperation In-Air Visibilityallows visual inspectionof all components without the inconvenience or expense associated with equipment which must be de-energized for inspectionSuperlife Finishincludes phosphatizing,rust-inhibiting epoxy primerand Pad-Mount Green(Munsell 7GY )

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 sales@elliott-industries.com

Tags:

  Outdoor, Metal, Mounted, Operated, Switchgear, Enclosed, Operated pad mounted metal enclosed outdoor switchgear

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 15-kV Live Terminal 600 Amp Group Operated Pad …

1 15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 1 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric PolycarbonateImpact Resistant Bushing Guard withOpen Top is available In-Air Insulationeliminates leaking orcontamination ofinsulating medium forlong trouble-freeoperation In-Air Visibilityallows visual inspectionof all components without the inconvenience or expense associated with equipment which must be de-energized for inspectionSuperlife Finishincludes phosphatizing,rust-inhibiting epoxy primerand Pad-Mount Green(Munsell 7GY )

2 Polyurethane top coat -over 5 mils dryOptional Paint:Grey (Munsell 5BG )Tamper-Resistant Enclosuremeets National and RegionalEnclosure Integrity Standardsand virtually eliminates the entrance of airbornecontamination to reducemaintenanceHeavy duty 11-gauge steelenclosure is all-weldedconstruction for long lifeKinked roof prevents standing moistureCorrosion proof nameplateis located toprovide easyaccess for the operatorRemovable lift provisionswith blind holes fortamper resistanceGlass reinforced barriers meetNEMA GPO-3 StandardsCoordinated padlock and penta-head or optional hex-head bolt (top and bottom) provides bolted door security with visualconfirmation by supervisory bolt is made captive with astainless steel washer compressed to an oval shape to severely polycarbonate door safety latches on the doorsafety barrier are insulatingand require a positiveaction to remove thesafety barrier.

3 Barrier lifthandles are insulating andkeyed to prevent rotationOverlapping door andenclosure flanges - withother features - providetamper resistance to meetnational and regionalstandardsFuse Mountingsacceptcurrent-limitingclip mountedfusesStainless steel hinges arewelded to the door and theenclosure pinsare standardDoor-holder rods are stainlesssteel and hold the door open100 degrees or 140 degreesElliott Live TerminalThru-Bushings connectto the switch terminalswith x 2 copper busENCLOSURE OPTIONS:1) #5052H32 Aluminum2) 12-gauge #304L Stainless SteelGround lugs accept#6 - #2/0 ground cableS&C Mini-Rupter Switch with side- mounted non-removable handle, padlockable in Open or Close position. Provisionsfor key interlock are Mini-Rupter Switch with front- mounted non-removable handle, padlockable in Open or Close position.

4 Provisionsfor key interlock are Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 2 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric Two Ways Per Phase600 Amp S&C Mini-Rupter kV Grounded Wye Max Design95 kV BILCLCLSide ViewFront ViewDoor & Door Safety Barrier RemovedSection AASection BB600 Amp S&C #255243-S1 Mini-Rupter Switch, with side mounted non-removable handle,padlockable in Open or Close position, provisions for key interlock are standardOption G2: Ground studs at main contact of SwitchOption G3: Ground studs at bottom Terminal of FusesOption K.

5 Key interlockCatalog NumberOperating HandleFuse MountingDim. A EMEHGL-15-311S-LT-RHMR-CM5 Right Side (Shown Above) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-LT-LHMR-CM5 Left Side (Opposite Hand) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-LT-RHMR-CM6 Right Side (Shown Above) kV (Code 6) to 125 AmpClip mounted Current-Limiting EMEHGL-15-311S-LT-LHMR-CM6 Left Side (Opposite Hand) kV (Code 6) to 125 AmpClip mounted Current-Limiting 15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 3 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric Two Ways Per Phase600 Amp S&C Mini-Rupter kV Grounded Wye Max Design95 kV BILCLCLS ection BBFront ViewDoor & Door Safety Barrier RemovedSection AAOption G2: Ground studs at main contact of SwitchOption G3: Ground studs at bottom Terminal of FusesOption K.

6 Key interlock600 Amp S&C #255243-S1 Mini-Rupter Switch, with frontmounted non-removable handle,padlockable in Open or Close position, provisions for key interlock are standardCatalog NumberOperating HandleFuse MountingDim. A EMEHGL-15-311S-LT-MR-CM5 Front (Shown Above) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-LT-MR-CM6 Front (Shown Above) kV (Code 6) to 125 AmpClip mounted Current-Limiting 15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 4 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric Two Ways Per Phase600 Amp S&C Mini-Rupter kV Grounded Wye Max Design95 kV BILCLCLO ption G2: Ground studs at main contact of SwitchOption G3: Ground studs at bottom Terminal of FusesOption K: Key interlockOption LBG.

7 Impact resistant clear polycarbonate Bushing Guard600 Amp S&C #255243-S1 Mini-Rupter Switch, with side mounted non-removable handle,padlockable in Open or Close position, provisions for key interlock are standardSide ViewFront ViewDoor & Door Safety Barrier RemovedSection AASection BBCatalog NumberOperating HandleFuse MountingDim. A EMEHGL-15-311S-EL6-RHMR-CM5 Right Side (Shown Above) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-EL6-LHMR-CM5 Left Side (Opposite Hand) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-EL6-RHMR-CM6 Right Side (Shown Above) kV (Code 6) to 125 AmpClip mounted Current-Limiting EMEHGL-15-311S-EL6-LHMR-CM6 Left Side (Opposite Hand) kV (Code 6) to 125 AmpClip mounted Current-Limiting 15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc.

8 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 5 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric Two Ways Per Phase600 Amp S&C Mini-Rupter kV Grounded Wye Max Design95 kV BILCLCLS ection BBFront ViewDoor & Door Safety Barrier RemovedSection AAOption G2: Ground studs at main contact of SwitchOption G3: Ground studs at bottom Terminal of FusesOption K: Key interlockOption LBG: Impact resistant clear polycarbonate Bushing Guard600 Amp S&C #255243-S1 Mini-Rupter Switch, with front mounted non-removable handle,padlockable in Open or Close position, provisions for key interlock are standardCatalog NumberOperating HandleFuse MountingDim.

9 A EMEHGL-15-311S-EL6-MR-CM5 Front (Shown Above) kV (Code 5) to 140 AmpClip mounted Current-Limiting EMEHGL-15-311S-EL6-MR-CM6 Front (Shown Above) kV (Code 6) to 125 AmpClip mounted Current-Limiting 15-kV Live Terminal 600 Amp Group OperatedPad- mounted metal - enclosed outdoor Switchgear140 Amp (Max) Clip Mount Current-Limiting Fuses Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 6 2015NX and X-Limiter are either registered trademarks or trademarks of Eaton in the and other is a registered trademark of S&C Electric Specification - Page 1 of 2 GeneralThe switchgear shall be 15 kV Class, 95 kV BIL, 600 ampere continuous current, suitable for use on kV grounded wye max design systems.

10 The switchgear shall be constructed for connection to the utility system with bolt-on cable terminals and stress-relief devices (Elastimold modular terminators, Joslyn PS terminators or equal to be supplied by the user). The switchgear shall be designed for and contain three-pole, Group - Operated , load-interrupter switches and/or fuse mountings that accept current-limiting fuses as described below. A door safety barrier shall be provided inside the door(s) as recommended in IEEE Standard C2 (National Electrical Safety Code) Rule 381G. Tamper resistance shall meet the Enclosure Security requirements of IEEE Standard (Pad- mounted Equipment Enclosure Integrity). Together, the tamper resistance and the door safety barrier(s) shall resist unauthorized entry, protect authorized and unauthorized persons, and provide positive safety features when installed in areas accessible to the general public.