1523, 1524 Reference Thermometer Technical Guide

1523, 1524 Reference ThermometerTechnical GuideRevision 892401 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at to the HART 1523/1524 Info PageTest Equipment Depot - - 99 Washington Street Melrose, MA 02176 FAX - Fluke Corporation, Hart Scientific Division799 E. Utah Valley Drive American Fork, UT 84003-9775 USAP hone: + Telefax: + : subject to change without notice. Copyright 2008 Printed in USAL imited Warranty & Limitation of LiabilityEach product from Fluke Corporation, Hart Scientific Division ( Hart ) is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year(s) for the Reference Thermometer . The warranty period begins on the date of the shipment. Parts, product repairs, and services are warranted for 90 days. The warranty extends only to the original buyer or end-user customer of a Hart authorized reseller, and does not apply to fuses, disposable batteries or to any other product, which in Hart s opinion, has been misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling.

1523, 1524 Reference Thermometer Technical Guide Revision 892401 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431

Tags:

  Guide, Reference, Technical, 1425, 1325, Thermometer, 1524 reference thermometer technical guide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1523, 1524 Reference Thermometer Technical Guide

1 1523, 1524 Reference ThermometerTechnical GuideRevision 892401 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at to the HART 1523/1524 Info PageTest Equipment Depot - - 99 Washington Street Melrose, MA 02176 FAX - Fluke Corporation, Hart Scientific Division799 E. Utah Valley Drive American Fork, UT 84003-9775 USAP hone: + Telefax: + : subject to change without notice. Copyright 2008 Printed in USAL imited Warranty & Limitation of LiabilityEach product from Fluke Corporation, Hart Scientific Division ( Hart ) is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year(s) for the Reference Thermometer . The warranty period begins on the date of the shipment. Parts, product repairs, and services are warranted for 90 days. The warranty extends only to the original buyer or end-user customer of a Hart authorized reseller, and does not apply to fuses, disposable batteries or to any other product, which in Hart s opinion, has been misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling.

2 Hart warrants that software will operate substantially in accordance with its functional specifica-tions for 90 days and that it has been properly recorded on non-defective media. Hart does not warrant that software will be error free or operate without interruption. Hart does not warrant calibrations on the Reference authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Hart. Warranty support is available if product is purchased through a Hart authorized sales outlet or Buyer has paid the applicable international price. Hart reserves the right to invoice Buyer for importation costs of repairs/replacement parts when product purchased in one country is submit-ted for repair in another s warranty obligation is limited, at Hart s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Hart authorized ser-vice center within the warranty obtain warranty service, contact your nearest Hart authorized service center or send the prod-uct, with a description of the difficulty, postage, and insurance prepaid (FOB Destination), to the nearest Hart authorized service center.

3 Hart assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destina-tion). If Hart determines that the failure was caused by misuse, alteration, accident or abnormal condition or operation or handling, Hart will provide an estimate or repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU-LAR PURPOSE. HART SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCI-DENTAL. OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer.

4 If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. iii Table of Contents1 Before You Start .. Introduction .. Standard Equipment .. Safety Information .. Warning .. Cautions .. CE Comments .. EMC Directive .. Immunity Testing .. For Use As a Portable (Hand-held) Instrument .. For Use As a Benchtop Instrument (AC Adapter) .. Using Clamp-On Ferrites .. Emissions Testing .. Low Voltage Directive (Safety) .. Authorized Service Centers ..42 Quick Start .. Setup .. Specifications ..173 General Operation .. DC Power Source .. Probe .. Internal or External Reference junction compensation may be used with this instrument.. TC Internal Reference Junction .. TC External Reference Junction .. Probe Lock Function .. INFO-CON Connector ..264 Display Functions and User Interface .. Main Screen .. STATS.

5 C F .. HOLD ..291523, 1524 Reference Thermometer SETUP .. Channel T1 .. Probe .. Config .. Base X .. Aux Displ .. Temp Res .. RJ .. Channel T2 (1524 Only) .. Probe .. Config .. Base X .. Aux Displ .. Temp Res .. Instrument .. Fast Scan Mode .. Contrast .. Auto-Off .. Backlight Time .. Serial Port .. Baud Rate .. Date/Time .. SAVE .. ARROWS, UP, DOWN .. ENTER .. RECALL .. Review Saved .. Send Saved .. Delete Saved .. Send Logs .. Delete Logs .. NEXT .. SHIFT .. RESET .. mV .. TREND .. LOG .. Free .. Interval .. Tag .. Session ..38v HOME ..385 LOGS .. DEMAND LOG .. AUTO-LOG .. Auto-Log Operation .. Sending Auto Log Data to a Computer .. Data Upload Format .. Deleting Auto Log Data ..416 Digital Communication Interface .. Wiring .. Setup .. Serial Operation .. Data Upload Format .. Command Syntax .. Serial Commands by Function or Group .. Serial Commands - Alphabetic Listing ..487 Calibration of Your Reference Thermometer Readout.

6 General .. Introduction .. Fundamentals .. Environmental Test Conditions .. Calibration Equipment .. Manual Calibration .. General .. As Found Data Procedure .. As Found Calibration Parameters .. As Found Data .. Alignment Alignment Test Data .. Calculate New Adjustment Values .. As Left Data .. Preparation for Reference Thermometer Calibration .. Serial Communication .. Cabling .. Scan Mode ..811523, 1524 Reference Thermometer AC Adapter .. Manual Calibration Process .. Procedure .. Visual Inspection .. 1523/24 Calibration Parameters (As Found) .. 1523/24 Accuracy Test (As Found) .. 1523/24 Alignment .. L75_OHMS Range .. LO_OHMS Range .. MED_OHMS Range .. HI_OHMS Range .. Millivolt Range .. 1523/24 As Left Test Data ..938 Troubleshooting ..959 Maintenance ..97 Index ..99vii FiguresFigure 1 Clamp-On Ferrite ..4 Figure 2 Input/Output Connections - 1523 ..7 Figure 3 Input/Output Connections - 1524 ..8 Figure 4 Keys.

7 9 Figure 5 1523 Menu ..11 Figure 6 1523 Menu (cont) ..11 Figure 7 1523 Menu (cont) ..12 Figure 8 1524 Menu ..14 Figure 9 1524 Menu (cont) ..14 Figure 10 1524 Menu (cont) ..15 Figure 11 1524 Menu (cont) ..16 Figure 12 1524 Menu (cont) ..17 Figure 13 1524 Menu (cont) ..17 Figure 14 12V DC Power source Polarity ..24 Figure 15 Probe wiring 16 RS-232 wiring ..43 Figure 17 Flow chart for manual calibration ..791523, 1524 Reference Thermometer viiiTablesTable 1 International Symbols ..3 Table 2 1523 Input/Output Connections ..7 Table 3 1524 Input/Output Connections ..8 Table 4 1523 Key Functions ..10 Table 5 1524 Key Functions ..12 Table 6 Table 6 General Specifications ..18 Table 7 Table 7 Millivolt Measurement ..18 Table 8 Reference Junction Compensation ..18 Table 9 Table 8 Ohms Measurement, RTDs ..18 Table 10 Table 9 Ohms Measurement, Thermistor ..19 Table 11 Equivalent temperature accuracies derived from primary specifications ( , mV).

8 19 Table 12 Temperature, Thermocouples External Reference Junction ..20 Table 13 Temperature, RTD Ranges and Accuracies (RTD-90) ..21 Table 14 Temperature, Thermistor ..21 Table 15 Fast Scan Mode Specifications ..21 Table 16 Sample Interval per Channel in Seconds ..21 Table 17 Channel to Channel Differential Specifications ..22 Table 18 Commands by Function or Group ..45 Table 19 Statistical Types ..72 Table 20 Probe Conversion Types ..72 Table 21 Probe Characterization Parameters ..73 Table 22 Calibration Range Identifiers ..74 Table 23 Demand Log Statistical Types ..75 Table 24 Error Messages ..75 Table 25 Test Equipment Specifications ..78 Table 26 Standard Reference Resistor Specification ..78 Table 27 Standard Voltage Reference Specification ..78 Table 28 1523/24 Accuracy Test Settings and Specifications ..81 Table 29 1523/24 Accuracy Test Settings and Specifications Voltage ..82 Table 30 As Found Readout/Calibration Parameter Settings ..82 Table 31 1523/24 Alignment Settings.

9 891 Before You StartSafety InformationBefore You Start1 The Reference Thermometers (1523, 1524) are designed to be reliable, stable, tem-perature measuring instruments that can be used in the field or laboratory. They offer accuracy, portability, and speed for nearly every field calibration application. The instruments have been designed with the field user in mind and are easy to use while maintaining stability, uniformity, and accuracy comparable to some laboratory instru-ments. Your Fluke 1523 and 1524 thermometers are a handheld, battery operated instrument that measures temperature using Platinum resistance Thermometers (PRT), Thermistors, and Thermocouples (TC). Standard EquipmentUnpack the instrument carefully and inspect it for any damage that may have occurred during shipment. If there is shipping damage, notify the carrier that the following components are present:1523/1524 Reference Thermometer with 3 AA batteries AC Adapter, with power cord RS-232 Cable User s Guide Documentation CD Report of Calibration and calibration label Clamp-on ferrite(s) If all items are not present, contact an Authorized Service Center.

10 (See Section , Authorized Service Centers on page 4.) Safety InformationThe Reference Thermometer is designed in accordance with EN 61010-1 {2nd Edi-tion}, and CAN/CSA No Use this instrument only as specified in this manual, otherwise the protection provided by the instrument may be Warning identifies conditions and actions that pose hazard(s) to the user; a Caution identifies conditions and actions that may damage the instrument being used. International symbols used on the Reference Thermometer and in this manual are ex-plained in Table 1 on page WarningTo avoid possible electric shock or personal injury:Do not use the Reference Thermometer in environments other than those listed in the user s , 1524 Reference ThermometerSafety Information2Do not use the Reference Thermometer for any application other than that which is specified. The instrument was designed for temperature measurement and calibration. Any other use of the instrument may cause unknown hazards to the the Reference Thermometer is used in a manner not in accordance with the equipment design, the operation and the protection provided by the instrument may be impaired.