Example: quiz answers

156 Day Trouble Zone The specified zone which …

100 MedicalZoneA non-specific medical condition exists101 Personal EmergencyZoneEmergency Assistance request102 Fail to report inZoneA user has failed to activate a monitoring device110 FireZoneA non-specific fire alarm condition exists111 SmokeZoneAn alarm has been triggered by a smoke detector112 CombustionZoneAn alarm has been triggered by a combustion detector113 Water FlowZoneAn alarm has been triggered by a water flow detector114 HeatZoneAn alarm has been triggered by a heat detector115 Pull StationZoneA pull station has been activated116 DuctZoneAn alarm has been triggered by a duct detector117 FlameZoneAn alarm has been triggered by a flame detector118 Near AlarmZoneA near-alarm condition has been detected on a fire sensor120 PanicZoneA non-specific hold-up alarm exists121 DuressUserA duress code has been entered by a user122 SilentZoneA silent hold-up alarm exists123 AudibleZoneAn audible hold-up alarm exists124 Duress Access grantedZoneA duress code has been entered and granted at an entry door125 Duress Egress grantedZoneA duress code has been entered and granted at an exit door126 Hold-up suspicion printUserA user has activated a trigger to indicate a suspicious condition127 Remote Silent PanicUserA silent panic alarm has been initiated remotely by a user129 Panic VerifierZoneA confirmed Hold-up condition exists130 BurglaryZoneA burglary zone has

156 Day Trouble Zone The specified zone which monitors trouble by day has reported a fault condition while disarmed 157 Low bottled gas level Zone The gas level ...

Tags:

  Zones, Which, Specified, Zone the specified zone which

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 156 Day Trouble Zone The specified zone which …

1 100 MedicalZoneA non-specific medical condition exists101 Personal EmergencyZoneEmergency Assistance request102 Fail to report inZoneA user has failed to activate a monitoring device110 FireZoneA non-specific fire alarm condition exists111 SmokeZoneAn alarm has been triggered by a smoke detector112 CombustionZoneAn alarm has been triggered by a combustion detector113 Water FlowZoneAn alarm has been triggered by a water flow detector114 HeatZoneAn alarm has been triggered by a heat detector115 Pull StationZoneA pull station has been activated116 DuctZoneAn alarm has been triggered by a duct detector117 FlameZoneAn alarm has been triggered by a flame detector118 Near AlarmZoneA near-alarm condition has been detected on a fire sensor120 PanicZoneA non-specific hold-up alarm exists121 DuressUserA duress code has been entered by a user122 SilentZoneA silent hold-up alarm exists123 AudibleZoneAn audible hold-up alarm exists124 Duress Access grantedZoneA duress code has been entered and granted at an entry door125 Duress Egress grantedZoneA duress code has been entered and granted at an exit door126 Hold-up suspicion printUserA user has activated a trigger to indicate a suspicious condition127 Remote Silent PanicUserA silent panic alarm has been initiated remotely by a user129 Panic VerifierZoneA confirmed Hold-up condition exists130 BurglaryZoneA burglary zone has been violated while armed131 PerimeterZoneA perimeter zone has been violated while armed132 InteriorZoneAn interior zone has been violated while armed13324 Hour (Safe)

2 ZoneA 24 hour burglary zone has been violated134 Entry/ExitZoneAn Entry/Exit zone has been violated while armed135 Day/NightZoneAn Trouble by Day / alarm by Night zone has been violated while armed136 OutdoorZoneAn outdoor burglary zone has been violated while armed137 TamperZoneA burglary zone has been tampered with while armed138 Near alarmZoneA burg sensor has detected a condition which will cause it to go into alarm if the condition worsens139 Intrusion VerifierZoneThe specified zone has verified that an intrusion has occurred140 General AlarmZoneThe specified zone is in an alarm condition141 Polling loop openZoneAn open circuit condition has been detected on a polling loop while the system was armed142 Polling loop shortZoneA short circuit condition has been detected on a polling loop while the system was armed143 Expansion module failureZoneA general failure condition has been detected on an expansion module while the system was armed144 Sensor tamperZoneA sensor's tamper has been violated (case opened)145 Expansion module tamperZoneAn expansion module's tamper has been violated (cabinet opened)

3 146 Silent BurglaryZoneA burglary zone has been violated while armed with no audible notification produced147 Sensor Supervision FailureZoneA sensor's supervisory circuit has reported a failure while the system was armed15024 Hour Non-BurglaryZoneA non-burglary zone has been faulted151 Gas detectedZoneThe gas detector assigned to the specified zone has reported a fault condition152 RefrigerationZoneThe refrigeration detector assigned to the specified zone has reported a fault condition153 Loss of heatZoneThe temperature detector assigned to the specified zone has reported a fault condition154 Water LeakageZoneThe water leak detector assigned to the specified zone has reported a fault conditionContact ID as of 11/28/2018155 Foil BreakZoneThe specified zone which is assigned to foil used as glass break detection has reported a fault condition156 Day TroubleZoneThe specified zone which monitors Trouble by day has reported a fault condition while disarmed157 Low bottled gas levelZoneThe gas level detector assigned to the specified zone has reported a fault condition158 High tempZoneThe over-temperature detector assigned to the specified zone has reported a fault condition159 Low tempZoneThe under-temperature detector assigned to the specified zone has reported a fault condition161 Loss of air flowZoneThe air flow detector assigned to the specified zone has reported a fault condition162 Carbon Monoxide detectedZoneThe carbon monoxide detector assigned to the specified zone has reported a fault condition163 Tank levelZoneThe tank level detector assigned to the specified zone has reported a fault condition168 High HumidityZoneA High Humidity condition has been detected169 Low HumidityZoneA Low Humidity condition has been detected200 Fire SupervisoryZoneThe supervisory circuit of the specified fire zone has reported a

4 Fault condition201 Low water pressureZoneThe water pressure sensor assigned to the specified zone has reported a fault condition202 Low CO2 ZoneThe CO2 pressure sensor assigned to the specified zone has reported a fault condition203 Gate valve sensorZoneThe gate valve sensor in the fire sprinkler system assigned to the specified zone has reported a fault condition204 Low water levelZoneThe water level sensor assigned to the specified zone has reported a fault condition205 Pump activatedZoneThe pump activity detector assigned to the specified zone has reported an active condition206 Pump failureZoneA pump output monitor assigned to the specified zone has reported a fault condition300 System TroubleZoneA general system Trouble condition has been reported by the specified zone301AC LossZoneAC power loss has been detected at a control or expansion module while the system was disarmed302 Low system batteryZoneA battery has failed a load test while the system was disarmed303 RAM Checksum badZoneA test of the system's memory has failed304 ROM checksum badZoneA test of the system's executable memory has failed305 System resetZoneThe system has reset and restarted306 Panel programming changedZoneThe programmed configuration of the panel has changed307 Self-test failureZoneThe system has failed a self-test308 System shutdownZoneThe system has been shut down and has stopped functioning309 Battery test failureZoneThe system backup battery has failed a load test while the system was disarmed310 Ground faultZoneThe panel has detected a ground fault condition311 Battery Missing/DeadZoneThe system has detected that the backup battery is either missing or completely Supply OvercurrentZoneThe system power supply has reported an excessive current draw condition313 Engineer ResetUserThe specified service person has issued a

5 System reset314 Primary Power Supply FailureZoneThe system's primary power supply has failed a supervision test. Radio devices indicate this when the backup battery charging circuit has failed its supervision test315 System TroubleN/A to Honeywell Controls (DSC Only)316 System TamperZoneThe system has been tampered with and may have been compromised317 Control Panel System TamperZoneThe control panel tamper switch has been violated while the system is Disarmed320 Sounder/Relay ZoneA Trouble condition exists in the system's sounder/relay circuit321 Bell 1 ZoneA Trouble condition exists in the primary bell circuit322 Bell 2 ZoneA Trouble condition exists in the secondary bell circuit323 Alarm relay ZoneA Trouble condition exists in the system's alarm relay circuit324 Trouble relayZoneA Trouble condition exists in the system's Trouble relay circuit325 Reversing relay ZoneThe specified TELCO reversing relay has reported a Trouble condition326 Notification Appliance Ckt.

6 # 3 ZoneA Trouble condition exists in the bell #3 circuit327 Notification Appliance Ckt. #4 ZoneA Trouble condition exists in the bell #4 circuit330 System Peripheral troubleZoneA system peripheral device has reported a Trouble condition331 Polling loop openZoneAn open circuit condition has been detected on a polling loop while the system was disarmed332 Polling loop shortZoneA short circuit condition has been detected on a polling loop while the system was disarmed333 Expansion module failureZoneA general failure condition has been detected on an expansion module while the system was disarmed334 Repeater failureZoneA repeater in the system has reported a failure condition while the system was disarmed335 Local printer out of paperZoneThe printer attached to the panel has reported an Out Of Paper condition336 Local printer failureZoneThe printer attached to the panel has reported a failure condition337 Exp. Module DC LossZoneAn expansion module has detected a DC power loss338 Exp.

7 Module Low expansion module has detected a low battery condition339 Exp. Module ResetZoneAn expansion module has reset341 Exp. Module Tamper ZoneAn expansion module has detected its taper switch has been faulted342 Exp. Module AC LossZoneAn expansion module has detected the loss of AC power343 Exp. Module self-test failZoneAn expansion module has failed a self-test344RF Receiver Jam DetectZoneAn RF receiver has detected the presence of a jamming signal, preventing it from receiving normal signals from the system RF devices345 AES Encryption disabled/ enabledZoneE345 AES Encryption has been disabledR345 AES Encryption has been enabled350 Communication troubleZoneThe system has experienced difficulties communicating with the central station351 Telco 1 faultZoneThe system has detected a fault on the primary dial-up line352 Telco 2 faultZoneThe system has detected a fault on the secondary dial-up line353 Long Range Radio xmitter faultZoneA fault has been detected in the long range radio subsystem354 Failure to communicate eventZoneThe system was unable to communicate an event to the central station355 Loss of Radio supervisionZoneThe radio has not reported in its designated supervision interval356 Loss of central pollingZoneThe radio has detected a loss in the polling signal from it's associated receiver357 Long Range Radio VSWR problem ZoneThe Long Range Radio

8 Has reported a transmitter/antenna problem358 Periodic Comm Test Fail /RestoreZoneA periodic Communication path test has failed359 AlarmNet Communications FailureZoneE359 Comm Fail- Communicator did not check in with AlarmNet during its supervision intervalP359 Comm Fail ReminderR359 Comm Fail Restored360 New RegistrationA Communicator has been newly registered with AlarmNet361 Authorized Substitution RegistrationAn Authorized Substitution Registration was successful362 Unauthorized Substitution RegistrationAn Unauthorized Substitution Registration was blocked - Need PIN365 Module Firmware UpdateA Firmware update was sent to the Communicator366 Module Firmware Update FailedA Firmware update was sent to the Communicator and failed370 Protection loopZoneThe specified protection loop has reported a Trouble condition371 Protection loop openZoneThe specified protection loop has reported an open-loop Trouble condition372 Protection loop shortZoneThe specified protection loop has reported a shorted-loop Trouble condition373 Fire troubleZoneA fire sensor has detected a Trouble condition on the specified zone while the system was disarmed374 Exit error alarm (zone)

9 ZoneAn exit error condition has been reported for the specified alarm zone375 Panic zone troubleZoneThe system has detected a Trouble condition on the panic zone376 Hold-up zone troubleZoneThe system has detected a Trouble condition on the hold-up zone377 Swinger TroubleZoneA fault has occurred on a zone that has been shut down due to excessive alarms378 Cross-zone TroubleZoneThe specified zone in a cross-zone configuration has faulted without a fault on its corresponding cross-zone in a specific time period380 Sensor troubleZoneThe specified sensor has reported a Trouble condition381 Loss of supervision - RFZoneThe specified zone has failed to report in during its designated supervision period382 Loss of supervision - RPMZoneAn Remote Polled Module assigned to the specified zone has failed supervision383 Sensor tamperZoneThe tamper switch on the specified sensor has been faulted384RF low batteryZoneThe specified battery powered RF zone has reported a low battery condition385 Smoke detector Hi sensitivityZoneA smoke detector's sensitivity level has drifted to the upper limit386 Smoke detector Low sensitivityZoneA smoke detector's sensitivity level has drifted to the lower limit387 Intrusion detector Hi sensitivityZoneAn intrusion detector's sensitivity level has drifted to the upper limit388 Intrusion detector Low sensitivityZoneAn intrusion detector's sensitivity level has drifted to the lower limit389 Sensor self-test failureZoneThe specified sensor has failed a self-test391 Sensor Watch troubleZoneA motion sensor has not been triggered within a pre-defined time interval392 Drift Compensation ErrorZoneA smoke detector cannot automatically adjust its sensitivity393 Maintenance AlertZoneThe specified zone requires maintenance394CO Detector needs replacementZoneThe specified Carbon Monoxide detector has

10 Reached end-of-life400 Open/CloseUserThe specified user has disarmed/armed the system401O/C by userUserThe specified user has disarmed/armed the system402 Group O/CUserA group of zones has been armed or disarmed403 Automatic O/CUserA partition has been automatically armed or disarmed404 Late to O/C (Note: use 453 or 454 instead )User 405 Deferred O/C (Obsolete- do not use )User 406 CancelUserThe specified user has cancelled the previously reported alarm condition407 Remote arm/disarmUserThe specified user has armed or disarmed the system from off-premises408 Quick armUserThe specified user has quick-armed the system409 Keyswitch O/CUserThe specified user has armed or disarmed the system using a keyswitch411 Callback request madeUserA remote site (central station) has requested the panel call it back412 Successful download/accessUserThe configuration data of the system has been successfully downloaded413 Unsuccessful accessUserA number of failed attempts have been made to remotely access the system414 System shutdown command receivedUserA central station has sent a system shutdown command to the panel415