Transcription of 1C EPC Combination Line Starters Explosionproof …
1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1 CEPC Combination line Startersand EnclosuresCl. I, Div. 1 & 2, Groups C, DCl. II, Div. 1, Groups E, F, GCl. II, Div. 2, Groups F, GCl. IIINEMA 3, 4, 7CD, 9 EFG, 12 ExplosionproofDust-IgnitionproofRaintigh tWet LocationsWatertightAssembled unitSeparated viewshowing majorcomponentsApplications:EPC Combination line Starters andenclosures are used: For across-the- line starting of polyphaseAC induction motors In locations which are hazardous due to thepresence of flammable vapors, gases orhighly combustible dusts In damp, wet or corrosive locations For installation indoors or outdoors atpetroleum refineries, chemical andpetrochemical plants and other processindustry facilities where similar hazardsexist To provide disconnecting means, motorbranch circuit protection, motor runningprotection, undervoltage protection andremote starting and stopping due to thecombination of thermal-magnetic circuitbreaker and magnetic motor starterFeatures.
2 Quick-opening covers less than two turnsto remove or install Three section design for ease of installation Water-shedding construction with femalethreads on top cover, male threads onbottom cover, and top cover skirted Specially located stops and locks insureadequate thread engagement and preventovertightening Separate replaceable mounting bracketattached to the rear of the body providesthree-point suspension for quickinstallation and leveling one keyhole slotat top and two open slots at bottom Bodies have two taper-tapped conduithubs with integral bushings on the top, andtwo more directly below Universal mounting plate and resetmechanism will accommodate any of themotor Starters and circuit breakers incatalog listing When interior mounting plate is removed,feeder and branch circuit conductors areeasily pulled into the wiring chamber.
3 Theinterior assembly, with breaker and starterattached, is then replaced, finalconnections made, and covers assembled External handle, which operates breakercan be padlocked in either "ON" or "OFF"positions Breaker is trip-free of the handle, thereforeit will open under short circuit or overload,even if the external handle is locked in the"ON" position Furnished with third overload relay asstandardCertifications andCompliances: NEC/CECC lass I, Division 1 & 2, Groups C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass III NEMA/EEMAC: 3, 4, 7CD, 9 EFG, 12 UL Standard: 698 CSA Standards: No. 30 Standard Materials: Body and cover copper-free aluminum Operating handle copper-free aluminum Operating shafts stainless steel Interior parts sheet steelStandard Finishes: Copper-free aluminum natural Stainless steel natural Sheet steel electrogalvanized withchromate finishElectrical Rating Range: Starters Sizes 0, 1 and 3 inclusive Breakers 100 and 150 ampere framesizes Motor Circuit Protectors 100 ampereframe size*Application is limited by starter , contactor, circuit breakeror motor circuit protector design Consult Factory Required for pilot lights on other than 120 volt controlcircuits.
4 One required for each lamp. Not suitable for NEMA :The following special options are availablefrom factory by adding suffix to Cat. No. andmany are available in kit form or for fieldaddition to existing units: See page 471 forlisting of kitsDescriptionSuffixControl circuit transformer 600/480/240 120 volts, 50 or 60 hertz (Sizes 0 and 1 100 50 VA)Fusible Primary and Contacts on starter orContactor*1 ..S7812 ..S7823 ..S783 Auxiliary Switch on Circuit Breaker orMotor Circuit Protector*1A/1B (1P2T) ..S7842A/2B (2P2T) ..S785 Side bosses drilled and tapped same size as standard hubs (except 15" dia. 1" size)..S366 Back boss drilled and tapped same size as standard hubs (except 15" dia. 1" size)..S367 Pushbuttons (heavy duty):START-STOP.
5 PB3 Selector switches (standard duty) ..RR3 Pilot lights:Red, 120 , 120 volt ..J3 LED pilot lights, in place of standardincandescent light transformers:240 volt ..T2480 volt ..T4600 volt ..T5 Space heaters:120 volt ..R11240 volt ..R22480 volt ..R44 Automatic reset overload overload relays (lightingcontactor)..CLLess overload relays (motor contactor)CMSeparate AC control circuit ..SpecifyInsulated neutral with 2 connectors(50, 100 & 225 amp) ..S146 Grounded neutral stud with 3connectors (50, 100 & 225 amp) ..S178 Pilot light holes drilled, tapped andplugged for future addition of pilotlightsOne Breather (Class I, Groups C,D, Class II, Groups E, F, G, Class III) ..S219 Standard Drain (Class I, Groups C, D,Class II, Groups E, F, G, Class III).
6 S198 Standard Breather and Drain (Class I,Groups C, D, Class II, Groups E, F, G,Class III) ..S198 VUniversal Breather Drain (Class I,Groups C, D, Class II, Groups F, G) ..S454 (2) Universal Breather Drains (Class I,Groups C, D, Class II, Groups F, G) ..S454V Less US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1 CEPC Combination line Startersand EnclosuresDimensions* (In Inches)Cl. I, Div. 1 & 2, Groups C, DCl. II, Div. 1, Groups E, F, GCl. II, Div. 2, Groups F, GCl. IIINEMA 3, 4, 7CD, 9 EFG, 12 ExplosionproofDust-IgnitionproofRaintigh tWet LocationsWatertight*Dimensions are approximate, not for construction purposes. For units with Control Circuit Transformer (suffix FT or FTPS).Single-Speed Non-Reversing Sizes 0, 1 and 3 startersEPC87 EPC87 FTPS orEPC87 FTInt.
7 "7"DimensionsDimensions a105/8105/8b261/16311/16c3511/164711/16d 1411/161411/16e63/4113/4f711/16711/16g11 5/8115/8h29j75/875/8k73/873/8l21/1621/16 m93/893/8n51/451/4p11/411 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1 CEPC Combination LineStarters and EnclosuresCl. I, Div. 1 & 2, Groups C, DCl. II, Div. 1, Groups E, F, GCl. II, Div. 2, Groups F, GCl. IIINEMA 3, 4, 7CD, 9 EFG, 12 ExplosionproofDust-IgnitionproofRaintigh tWet LocationsWatertightOrdering Information:To order an enclosure complete with starter and breaker, insert themanufacturer's symbols in the designated positions of the catalognumber. Symbols are shown in the footnotes the complete Cat. No. below and specify HP, voltage,frequency, RPM, type and full load ampere rating of motor orspecify ampere rating of only can be ordered.
8 Select from listings below. Instantaneous magnetic trip circuit breakers (magnetic circuitinterrupters) can be supplied. Consult Combination Starters with motor circuit protectors or singlespeed, non-reversing motors see page Speed, Non-Reversing with Circuit Breakers3-Pole 60 hertz, 600 VAC Maximum Starters are furnished with three heaters when heater ratings are fully StarterCircuit BreakerEnclosureMax. HPPolyphaseVoltsNEMASizeAmpRatingFrameHu bSize &CircuitBreakerCat. #WithStarter &CircuitBreakerCat. # 2120030EB11/47 EPC87 EPC870 30ED 6133240020 EHD11/47 EPC87 EPC870 20 EHD 6233480015 EHD11/47 EPC87 EPC870 15 EHD 6433480015 FDB11/47 EPC87 EPC870 15FD 6433600015FD11/47 EPC87 EPC870 15FD 6535240130 EHD11/47 EPC87 EPC871 30 EHD 6235480015 EHD11/47 EPC87 EPC870 15 EHD 6435480015 FDB11/47 EPC87 EPC870 15FD 6435600015 FDB11/47 EPC87 EPC870 15FD 65371/2240150 EHD11/47 EPC87 EPC871 50 EHD 62371/2480130 EHD11/47 EPC87 EPC871 30 EHD 64371/2480130 FDB11/47 EPC87 EPC871 30FD 64371/2600130 FDB11/47 EPC87 EPC871 30FD 65310480130 EHD11/47 EPC87 EPC871 30 EHD 64310480130 FDB11/47 EPC87 EPC871 30FD 64310600130 FDB11/47 EPC87 EPC871 30FD 653 Motor Starters .
9 ManufacturerSymbolAllen-BradleyABGeneral ElectricGSquare DDCutler-HammerW Circuit Breakers:Frames 100/150 AMPM anufacturerSymbol240V480V600 VGeneral ElectricTTTEBTED*TED*Cutler-HammerWTEHDE HDFB, FDB*Specify US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessEPC Combination line StartersSingle-Speed Non-Reversing with Motor Circuit Protectors3-Pole 60 hertz, 600 VAC MaximumCl. I, Div. 1 & 2, Groups C, DCl. II, Div. 1, Groups E, F, GCl. II, Div. 2, Groups F, GCl. IIINEMA 3, 4, 7CD, 9 EFG, 12 ExplosionproofDust-IgnitionproofRaintigh tWet LocationsWatertightOrdering Information:Select the complete Catalog No. below and specify HP, voltage,frequency, RPM, type and full load ampere rating of motors orspecify ampere rating of limiters may be ordered by specification*.
10 Motor Circuit ProtectorsManufacturerSymbolGeneral ElectricTPSquare DDPC utler-HammerWP Motor Starters :ManufacturerSymbolAllen-Bradley ABGeneral ElectricGSquare DDCutler-HammerW*General Electric or Cutler-Hammer MCPs Starters are furnished with three heaters when heater ratings are fully StarterEnclosure with Motor CircuitProtector and starter Max. HPPolyphase VoltsNEMASizeAmpRatingCat. #3240015 EPC870 15 HMCP 623348007 EPC870 7 HMCP 643360007 EPC870 7 HMCP 6535480015 EPC870 15 HMCP 6435600015 EPC870 15 HMCP 65371/2240130 EPC871 30 HMCP 62371/2480115 EPC871 15 HMCP 64310600115 EPC871 15 HMCP 65310480130 EPC871 30 HMCP 643