ECP Series Explosionproof Enclosures for OEM …

ECP Series Explosionproof Enclosures for OEM ApplicationsEngineeringSafety &ProductivityECP Series Explosionproof Enclosures 2 STANDARD MATERIALS Body and cover - Copper free aluminum Gasket - Neoprene Cover bolts - steel Hinges - aluminumOPTIONS (add to end of catalog number) PLT - Flat aluminum plate cover MP - Aluminum mounting plate installed S752 - Epoxy powder coat finish on exterior only S753 - Epoxy powder coat finish on interior and exterior S391 - Stainless steel cover bolts and hinges S756V - Breather and drain 4X - Stainless steel cover bolts, hinges, and external epoxy powder coatIntroducing the Explosionproof Control Panel (ECP), the latest addition to our portfolio of electrical products for OEM an optimized design and fast lead times for OEMs, ECP Enclosures are available in 40 standard sizes with optional conduit and device drilling and tapping.

ECP Series Explosionproof Enclosures for OEM Applications Engineering Safety & Productivity

Tags:

  Applications, Series, Enclosure, Explosionproof, Series explosionproof enclosures for oem, Series explosionproof enclosures for oem applications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ECP Series Explosionproof Enclosures for OEM …

1 ECP Series Explosionproof Enclosures for OEM ApplicationsEngineeringSafety &ProductivityECP Series Explosionproof Enclosures 2 STANDARD MATERIALS Body and cover - Copper free aluminum Gasket - Neoprene Cover bolts - steel Hinges - aluminumOPTIONS (add to end of catalog number) PLT - Flat aluminum plate cover MP - Aluminum mounting plate installed S752 - Epoxy powder coat finish on exterior only S753 - Epoxy powder coat finish on interior and exterior S391 - Stainless steel cover bolts and hinges S756V - Breather and drain 4X - Stainless steel cover bolts, hinges, and external epoxy powder coatIntroducing the Explosionproof Control Panel (ECP), the latest addition to our portfolio of electrical products for OEM an optimized design and fast lead times for OEMs, ECP Enclosures are available in 40 standard sizes with optional conduit and device drilling and tapping.

2 Pilot Lights Push Buttons Selector Switches Circuit Breaker Handles PLT Cover Allows for WindowSee your Crouse-Hinds representative for a full list of available DEVICESECP Size (W x L)Maximum No. of Cover DevicesDevice Layout04 x 0621 X 204 x 1651 X 506 x 0862 X 306 x 1282 X 408 x 0893 X 308 x 1093 X 308 x 12123 X 410 x 1093 X 312 x 12164 X 412 x 18246 X 414 x 14255 X 516 x 16366 X 616 x 24549 X 618 x 306611 X 624 x 309911 X 924 x 3611713 X 9* Requires selecting 4X AND COMPLIANCES Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III UL Standard 1203 cUL to CSA No. 30, No. 25 NEMA Type 3, 3R, 4, 7 BCD, 9 EFG enclosure Type 4X* Available for sizes 1212 and Features & Benefits132541.

3 Bolt-on / Tap-In Mounting Feet Allows for easy field-replacement in case mounting feet are damaged or Standard Internal Mounting Pads Factory drilled and tapped, internal mounting pads enable the installer to add a mounting plate in the field. Standard on all Standard Aluminum Hinge Aluminum hinges standard on sizes 121204 and larger, and are available on sizes 081006 through 101406 by adding suffix S598. Stainless-steel cover bolts and hinges are available by adding suffix Up To 3 In Diameter Factory-machined, drilled and tapped entries up to three inches in diameter. UL / cUL certified for field addition of drilled and tapped entries on sides, top, bottom, or back of the Stroke-sanded Finish Stroke-sanding creates smoother surface for installation of push button / pilot light operators.

4 Optional epoxy coat finish available for NEMA 4X requirements. Optional Aluminum Plate Cover Provides greater surface area for installation of push button / pilot light operators. Allows for installation of windows in plate cover. Strong, durable, non-porous Standard Neoprene Gasket Comes standard in all sizes. Provides NEMA 4 rating for Series Explosionproof Enclosures 4 ECP Series Enclosures are furnished with or without drilled and tapped openings. Drilling and tapping of conduit openings and device openings in the cover are subject to the limitations of maximum size and number of openings as well as spacings. All machining must be done prior to Nominal DimensionsUsable DepthOverall DimensionsMountingWeight[LB]Weight[KG]

5 Catalog NumberWLDABCEFECP0406040406044-5/88-11/3 210-11/326-1/857-1/2167 ECP0416040416045-5/88-1/220-1/26-5/32157 -1/83315 ECP0608040608044-5/810-15/3212-15/326-3/ 1679-1/82411 ECP0608060608066-5/810-15/3212-15/328-3/ 1679-1/83215 ECP0612040612044-5/810-1/216-1/26-3/1611 9-1/83215 ECP0808060808066-5/812-15/3212-15/328-7/ 32711-1/83717 ECP0810060810066-3/412-21/3214-21/328-9/ 16911-1/84520 ECP0812040812044-5/812-1/216-1/26-3/8111 1-1/83918 ECP0812060812066-3/412-21/3216-1/28-9/16 1111-1/85324 ECP0812080812088-5/812-1/216-1/210-3/811 11-1/85625 ECP1010061010066-3/414-21/3214-21/328-9/ 16913-1/85224 ECP1010081010088-5/814-21/3214-21/3210-3 /8913-1/85927 ECP1014061014066-5/814-21/3218-21/328-15 /321313-1/86630 ECP1212041212044-63/6416-57/6416-57/647- 3/16714-15/166228 ECP121206121206716-27/3216-27/329-1/8715 -5/166831 ECP121208121208916-27/3216-27/3211-1/871 5-5/167434 ECP1218061218066-25/3217-1/823-1/88-31/3 21214-15/1610246 ECP1218081218088-25/3217-1/823-1/811-1/8 1214-15/1611050 ECP122408*1224088-15/1617-1/429-1/411-5/ 81814-15/1614968 ECP122410*12241010-15/1617-1/429-1/413-5 /81814-15/1615872 ECP123608*1236088-15/161741-3/6411-59/64 3014-15/16247112 ECP141406141406718-7/818-7/89-3/8917-5/1 69342 ECP141408141408918-7/818-7/811-3/8917-5/ 1610146 ECP1414101414101118-7/818-7/813-3/8917-5 /1610849 ECP1616061616067-9/1620-61/6420-61/649-5 1/641018-15/1611753 ECP1616081616089-9/1620-61/6420-61/6411- 51/641018-15/1612557

6 ECP1624081624089-3/820-7/820-7/812-11/16 182019589 ECP1818061818067-3/822-7/822-7/810-7/161 221-9/1615370 ECP1818081818089-1/422-7/822-7/812-7/161 221-9/1616474 ECP18181018181010-15/1622-7/822-7/814-7/ 161221-9/1617579 ECP182408*1824089-7/1623-13/3229-13/3212 -5/161822-3/8223101 ECP182410*18241011-7/1623-13/3229-13/321 4-5/161822-3/8235107 ECP1830081830089-3/8243612-5/82422304138 ECP183608*1836089-11/3223-21/3241-21/321 2-39/643022-3/8355161 ECP183610*18361011-21/6423-21/3241-21/32 14-57/643022-3/8376171 ECP242408*2424089-7/1629-21/6429-21/6412 -17/321828-3/8279127 ECP242410*24241011-7/1629-21/6429-21/641 4-17/321828-3/8301137 ECP2430082430089-1/4303613-1/82428428194 ECP2436082436089-1/429-15/1641-15/1613-1 /43029-1/2481218 ECP24361024361011-1/429-55/6441-55/6415- 1/83029533242 enclosure Ordering Information and Dimensions*Will be available beginning March 2013.

7 The location, quantity, and maximum sizes must be in accordance with the following and Tapping for EntriesDrilled and Tapped Conduit OpeningsMinimum Center-to-Center Distance (In.)ConduitSize1/23/411-1/41-1/222-1/23 1/21-1/23/41-5/81-3/411-3/41-7/821-1/422 -1/82-1/42-1/21-1/22-1/82-1/42-3/82-5/82 -3/422-3/82-1/22-5/82-7/833-1/42-1/22-3/ 42-7/83-1/83-1/43-3/83-5/83-7/833-1/83-1 /43-3/83-1/23-5/844-1/44-5/8 Minimum clearance for unions EquivalentsNPT Conduit SizeMetric Opening1/2M16 x x x x x x x x Area - SidewallDefined Area - BackwallCatalog * * * * * * * * * Area Dimensions - Sidewall and BackwallDefined AreaXYTop and Bottom (Long Side)Defined AreaZXSides (Short Side) 6 ECP Series Explosionproof Enclosures The number of entries is limited by the total removed area of the entries.

8 To calculate, add up all individual entry areas and cross-check with the total removed area allowed in the tables Removal Rules - Sides and BackRemoved Area Per Threaded Entry Size(Surface Area Removed - Inch2)Trade Size1 Hole2 Holes3 Holes4 Holes1 Removed Area Per enclosure AllowedAllowable Area to RemoveCatalog NumberLong Side Inch2 Short Side Inch2 Back AreaXYTop and Bottom (Long Side)Defined AreaSides (Short Side)Z7 Defined AreaCatalog NumberCover StyleMounting FeetABAllowable Area To Remove Cover number of entries is limited by the total removed area of the entries. To calculate, add up all individual entry areas and cross-check with the total removed area allowed in the tables Area and Removal Rules - TREATMENT:REDRAWN DATEORIGINAL DATEUNLESS OTHERWISE SPECIFIEDTOLERANCESAPPROVED BYMATERIAL:FINISH:PATT.

9 BYCHECKED BYDRAWN BYUSED ONAPPLICATIONNEXT NUMBER:TITLECODE IDENT. 06/2009DO NOT SCALE DRAWINGD1020000000 THICKF inishCODE ..MM/DD/YYYYYour NameCHK_BYAPPR_BYTitle Line 1 Title Line 2 FIRST MADE FOR Catalog Family0000000revSCALE 1:4WT. LBSHEET 1 OF 1 THIS IS PROPERTY OF COOPER CROUSE-HINDS, LLC ANDCONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION. POSSESSION DOES NOT CONVEY ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH IT WAS SUPPLIED MAY NOT BE MADE WITHOUTEXPRESS WRITTEN PERMISSION OF COOPER CROUSE-HINDS, LLC. THIS DRAWING IS ON LOAN AND IS TO BE RETURNED UPON .005 .01.

10 3 NOTES:1. THIRD ANGLE PROJECTIONABCD12345678 ADCB87654321 UNLESS OTHERWISE SPECIFIED, ALL PRIMARY DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] ARE IN Area Removed Per Threaded Operator - Inch2 Thread Size and TypeArea Removed Per Device3/4 - 14 - 20 - 20 - 18 : A quantity of 22, 3/4 - 14 NPSM devices would utilize inches2, meaning the ECP1212 would not accommodate this number of Authorized Cooper Crouse-Hinds Distributor is:Printed in USA5065-0113 Cooper US, Travis Street, Suite 5600 Houston, TX more information:If further assistance is required, contact your local Cooper Crouse-Hinds Representative. Call customer service at 866-764-5454, or email (Global Headquarters):Cooper Crouse-HindsWolf & Seventh North StreetsSyracuse, NY 13221(866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) (Germany):Cooper Crouse-Hinds GmbH49 (0) 6271 806-50049 (0) 6271 Crouse-Hinds CanadaToll Free: 800-265-0502 FAX: (800) 263-9504 FAX Orders Only: (866) 653-0645 Middle East (Dubai):Cooper Crouse-Hinds LLC971 4 4272500 FAX: 971 4 4298521 Mexico/Latin America/Caribbean:Cooper Crouse-Hinds, de : Crouse-Hinds Pte.