vista -10 SESECURITY SYSTEMPROGRAMMINGGUIDEN7227V1 PRGD 4/97 2 TABLE OF CONTENTSP rogramming .. 3 Mechanics of .. 7 General programming Information .. 7 Entering the programming Mode .. 7 programming a Data Field .. 8 Reviewing a Data Field/Erasing an Entry in a Data Field .. 8 Interactive Menu Mode programming (Q56, Q80, Q81, Q82, & Q83 .. 8 Loading Factory Defaults .. 8 programming System Setup Fields .. 8 Exiting the programming Mode .. 85800 Series Transmitter Input Loop .. 9 Alpha Vocabulary List (For Entering Zone Descriptors) .. 10 Character (ASCII) Chart (For Adding Custom Words) .. 10 Zone Response Type .. 11 Data Field .. 13 Remote programming and Control (Downloading).)

– 3 – VISTA-10SE PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad (e.g., 6139) connected to the keypad terminals on the control. To set all program fields to Ademco default values:ÊÊKey 97.

Tags:

  Form, Programming, Tech, Info, Vista, Vista 10se, 10se, Vista 10se programming form

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Ê VISTA-10SE - info-techs.com

1 vista -10 SESECURITY SYSTEMPROGRAMMINGGUIDEN7227V1 PRGD 4/97 2 TABLE OF CONTENTSP rogramming .. 3 Mechanics of .. 7 General programming Information .. 7 Entering the programming Mode .. 7 programming a Data Field .. 8 Reviewing a Data Field/Erasing an Entry in a Data Field .. 8 Interactive Menu Mode programming (Q56, Q80, Q81, Q82, & Q83 .. 8 Loading Factory Defaults .. 8 programming System Setup Fields .. 8 Exiting the programming Mode .. 85800 Series Transmitter Input Loop .. 9 Alpha Vocabulary List (For Entering Zone Descriptors) .. 10 Character (ASCII) Chart (For Adding Custom Words) .. 10 Zone Response Type .. 11 Data Field .. 13 Remote programming and Control (Downloading).)

2 20 General Information .. 20 Equipment Required .. 20 Initial Download .. 20 Remote programming Information .. 20 Remote programming Advisory Notes .. 21 Summary of Connections .. Inside Back Cover (23) 3 vista - 10se programming FORML ocal programming requires the use of a 2-line Alpha keypad ( , 6139) connected to the keypad terminals on the set all program fields to Ademco default values: Key FunctionProgrammed Values[ ] = Default Value SYSTEM SETUP (Q20 Q27)Q20 INSTALLER CODE [4] [1] [1] [1]Enter 4 digits, ARM ENABLE [0]0 = no; 1 = yesQ22RF SYSTEM TYPE [0] 0 = none; 1 = 5700 System (4281 type rcvr); 2 = 5800 System (5881/ 5882 type rcvr).

3 Q23 FORCED BYPASS FUNCTION [0] 0 = none; 1 = bypass open HOUSE ID CODE [0][0]MUST enter (01-31) for 5700 System. Enter also for 5827/5827BD Keypad if used in 5800 RELAY MODULE [0] 0 = none; 3 = MODULE ACCESS CODE [0][0]1st digit: Enter 1 9; 2nd digit: Enter only #+11 for 'Q', #+12 for '#'.0 in either position = TO LONG RANGE RADIO [0]0 = no; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field Q47) will also besent via LRR. All dialer and LRR reports will be in Contact ID format (overriding field Q46selection).ZONE SOUNDS AND TIMING (Q28 Q39)Q28 SINGLE ALARM SOUNDING/ZONE [0] 0 = no; 1 = SOUNDER TIMEOUT [0] 0 = fire sounder timeout; 1 = no fire sounder BELL TIMEOUT [1] 0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 DELAY [2] 0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 secEXIT Delay = ENTRY Delay + 15 EXIT WARNING [1] 0 = no; 1 = programming (Q40 Q50) Note: In fields Q40, Q41, & Q42: Enter 0 9, # +11 for Q, # +12 for #, # +13 for a ACCESS CODE Enter up to 4 digits if PABX code is needed to access an outside line.

4 If fewer than 4 digitsentered, do not fill unused spaces exit by pressing Q (and press 41, if entering next field). To clear entries from field, press PHONE No. Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing Q (and press Q42,if entering next field). To clear entries from field, press PHONE No. Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing Q(and press 43 ifentering next field). To clear entries from field, press ACCT No. Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter Q as thefourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 asthe first digit of a 4-digit account number for Nos. 0000 0999. End field by pressing Q(and press next field).Examples: For Acct No. 1234, enter:1234 For Acct No. B234, enter:#+11234 For Acct No.

5 123, enter:123QQ45 PHONE SYSTEM SELECT [0]If Cent. Station IS NOT on a WATS line: 0 = Pulse Dial; 1 = Tone Dial If Cent. Station IS on a WATS line: 2 = Pulse Dial ; 3 = Tone Dial Entry of a number other than one specified will give unpredictable results. 4 Q46 REPORT FORMAT [0]Also see field Q27.[0 = 3+1, 4+1 ADEMCO L/S STANDARD]1 = 3+1, 4+1 RADIONICS STANDARD2 = 4+2 ADEMCO L/S STANDARD3 = 4+2 RADIONICS STANDARD6 or undefined = 4+2 ADEMCO EXPRESS7 = ADEMCO CONTACT ID REPORTING8 = 3+1, 4+1 ADEMCO L/S EXPANDED9 = 3+1, 4+1 RADIONICS EXPANDEDQ47 SPLIT/DUAL REPORTING [0] 0 = Disable (Backup report only)TO PRIMARY PHONE SECONDARY PHONE = Alarms, Restore, CancelOther Reports2 = All Reports except Open/Close, TestOpen/Close, Test3 = Alarms, Restore, CancelAll Reports4 = All Reports except Open/Close, TestAll Reports5 = All Reports(Dual Reporting)All Reports** A 10-digit code is sent to the pager consisting of a 4-digit Subscriber #, a 3-digit Event code, & a 3-digit User or Zone #.

6 See vista - 10se Installation Instructions for an explanation of the 10-digit PRIMARY PHONE PAGING No.* (SECONDARY)6 = All reports except Open/Close** Alarms, Open/Close, Troubles7 = All reports** Alarms, Troubles8 = All reports** Alarms, Open/Close, Troubles9 = All reports except Open/Close** Alarms, Open/Close for Users 5 25 , Troubles* Can only be used if Primary reporting is Ademco Contact ID. See field Q47 in the DATA FIELD DESCRIPTIONS SEC DIALER DELAY (BURG) [0] 0 = no; 1 = yesQ49 PERIODIC TEST MESSAGE [0] 0 = none; 1 = 24 hrs; 2 = wkly; 3 = monthly. Enter Test Code in field SELECT [0] 0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only reporting)Select 0 for all other OF ARMING DING [0] 0 = no; 1 = yes; 2 = yes, but with RF arming 3 RESPONSE TO OPEN [0] 0 = 400 ms nominal; 1 = 10 ms nominal Entry of a number other than one specified will give unpredictable ASSIGNMENT/ALARM REPORT CODES (See explanation on next page)ZONEZONEZONEALARM RPT CODEINPUTRF (Hex)TYPELOOP(Zn)(ZT)(RC)(In)(L)Wired Zone 101[01]HW Wired Zone 202[04]HW Wired Zone 303[03]HW Wired Zone 404[03]HW Wired Zone 505[09]HW Wired Zone 606[07]HW Keypad Panic (Q & #, or B)07[06] Keypad Duress08 Tamper0905 Keypad Panic (1 & Q, or A)95[00] Keypad Panic (3 & #, or C)96[00] RF EXPANSION ZONES:With 4281L, up to 4 RF expansion zones available; 4281M or 4281H, up to 8; ENTER FOR5881L, up to 8.

7 5881M or 5881H, up to 16. 5800 ONLY ZONEZONEZONEALARM RPT CODEINPUTRF (Hex)TYPE LOOP(Zn)(ZT)(RC) (in) (L)1st RF Expansion Zone2nd3rd4th 5 RF EXPANSION ZONES:With 4281L, up to 4 RF expansion zones available; 4281M or 4281H, up to 8; ENTER FOR5881L, up to 8; 5881M or 5881H, up to 16. 5800 ONLY ZONEZONEZONEALARM RPT CODEINPUTRF (Hex) DEVICE LOOP(Zn)(ZT)(RC) (in) (L)5th6th7th8th9th10th11th12th13th14th15 th16thEXPLANATION OF ZONE ASSIGNMENT TABLEZn = ZONE NUMBERZone Nos. are from 01 to 63, 95, 96. Some are Field Q22 set for RF (5700 or 5800), use Zone Nos. 10-63 .ZT = ZONE TYPE00 = Zone Not Used01 = Entry/Exit02 = Do not use03 = Perimeter04 = Interior Follower05 = Trouble Day/Alarm Night06 = 24 Hr Silent07 = 24 Hr Audible08 = 24 Hr Aux09 = Fire10 = Interior w/Delay20 = Arm Stay * 21 = Arm Away* 22 = Disarm* 23 = No Alarm Response* 20, 21, & 22 used for 5800 RF systems = ALARM REPORT CODE Two Hex Digits.

8 For each Hex Digit, enter: 00 09 for 0 9, 10 for A, 11 for B, 12 for C, 13 for D, 14 for E, 15 for "00" is entered in the first pair of boxes, there will be no report for that contact ID reporting, this is an enabling code only. Make any hex digit entry (other than "00") in the firstpair of boxes. The second pair of boxes will be = RF INPUT DEVICEHW:Hard WireEnter 3 for RF: Supervised RF (this is the default)Enter 4 for UR: Unsupervised RFEnter 5 for BR: Button Type RFL = RF INPUT LOOP Used with 5800 RF Input Devices. Record transmitter input PROGRAM SYSTEM STATUS, & RESTORE REPORTCODES (Q60 Q75):With a 3+1 or 4+1 Standard Format: Enter a code in the firstbox: 1-9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for "0" (not "#+10") in the first box will disable a "0" (not "#+10") in the second box will result in automaticadvance to the next field when an Expanded or 4+2 Format: Enter codes in both boxes(1st and 2nd digits) for 1-9, 0, or B-F, as de scribed "0" (not "#+10") in the second box will eliminate the ex-panded message for that "0" (not "#+10") in both boxes will disable the Ademco Contact ID Reporting: Enter any digit (other than"0") in the first box, to enable zone to report (entries in the secondboxes will be ignored).

9 A "0" (not "#+10") in the first box will disable the : For Code 3 (Single Digit), enter:30 For Code 32 (Two Digits), enter:32 For Code B2 (Hexadecimal) enter:#+112 SYSTEM STATUS REPORT CODES (Q60 Q68)Q60 TROUBLE REPORT CODE Q61 BYPASS REPORT CODE Q62AC LOSS REPORT CODE Q63 LOW BATTERY REPORT CODE Q64 TEST REPORT CODE Q65 OPEN/EXIT ALARM REPORT CODE / 2nd digit of OPEN REPORT is automatically sent as theuser number if expanded or 4+2 reporting is digit of EXIT ALARM REPORT is automatically sent asthe 2nd digit of the zone alarm report code programmed inQ56, if expanded or 4+2 reporting is CLOSE REPORT CODE / 2nd digit of any CLOSE REPORT is automatically sent as the usernumber, if expanded or 4+2 reporting is XMTR LOW BAT REPORT CODE Q68 CANCEL REPORT CODE RESTORE REPORT CODES (Q70 Q75)Q70 ALARM RESTORE REPORT CODE2nd digit is automatically sent as the 2nd digit of thezone alarm report code programmed in Q56, ifexpanded or 4+2 re porting is RESTORE REPORT CODE Q72 BYPASS RESTORE REPORT CODE Q73AC RESTORE REPORT CODE Q74 LOW BAT RESTORE REPORT CODE Q75RF XMTR LO BAT RST REPORT CODE 6 OUTPUT AND SYSTEM SETUP (Q80 Q92)Q80 OUTPUT RELAYSQ81 ZONE LISTS FOROUTPUT RELAYSP rogram only if Relays areto be used.

10 Q82 CUSTOM ALPHA EDITING: (Also entered from field Q56):See procedure in Installation MODE: Used for enrolling transmitters afterall other zone information has been programmed. (Also canbe accom plished from field Q56):See procedure in Installation SELECTION [0] 0 = None; 4 = AAV. 0 for UL installationsNote: AAV should not be used when Paging or Alarmreports are being sent to a secondary number. SeeAAV section in the Installation PER ARMED PERIOD [0]0 = 10 max total alarm + alarm restore; 1 = unlimitedDOWNLOAD INFORMATION (Q94, Q95)Q94 DOWNLOAD PHONE No. Enter up to 12 digits: 0-9; #+11 for 'Q'; #+12 for '#'; #+13 fora pause. Do not fill unused spaces. If fewer than 12 digitsentered, exit field by pressing Q (and press 95, if enteringnext field). To clear entries from field, press DET COUNT FOR DOWNLOADING [0][0=Disable Station Initiated Download]; 1-14=number ofrings (1-9, #+10=10, #+11=11, #+12=12, #+13=13,#+14=14); 15=answering machine defeat (#+15=15)Q96 INITIALIZES DOWNLOAD ID, SUBSCRIBERACCOUNT No.